Bhai humare Inverter 7.5kva 96volt ka jisme peak time pe 120volts show hote h per shaam ko 98volts per yeh inverter 90 volts pe aake cut mar deta h iska solution batao
@@dsenterprises123 sir mene ek jagah 7.5kva/120v alfa + diya hr customer ko , vo bolte he sham ko jese hi sun light off ho jata he battery half show karta he or battery ka voltage 25volt rahta he us time
False claim bay UTL IN smart mode As per your tagline Priority is like 1)solar 2)grid 3) Battery But as per your flowchart in daytime MCHINE will work LIKE PCU MODE HERE SECOND PREFERENCE IS BATTERY That is it will work like Solar -battery -grid Here my 50%battery is drain as per flowchart it will sense grid ar 11.5v But till my battery is 50% discharge And supposed that my grid is also fails at same time when battery reached to 11.5v At this condition i will have only 50%of battey backup as my battery is already 50%drain
@@dsenterprises123 - Thanks , Kitni der hold karna hai ? mujhe screen pe notification milega kya koi ki battery equalization ho raha hai ? thoda ache se explain kariye please. maine abhi abhi 5kv 48 v ka UTL ka Alpha invertor liya hai ..
Bhai humare Inverter 7.5kva 96volt ka jisme peak time pe 120volts show hote h per shaam ko 98volts per yeh inverter 90 volts pe aake cut mar deta h iska solution batao
Ampare setting bataye
Mashin power supply karna band hogaya h koee technician का no h to bheje Madhubani bihar.
9084646475
सर इस इन्वर्टर मैं बैटरी के चार्जिंग वोल्टेज और लो कट वोल्टेज कि सेटिंग नहीं है ।
जैसे utl के गामा प्लस मैं है
Ys nhi hai isme
@@dsenterprises123 तो सर इस इन्वर्टर मैं लो बैटरी कट ऑफ कितने वोल्ट पर सैट है और फूल चार्ज बैटरी कट ऑफ कितने पर सैट है
Bhaya Hamra same inverter hi working hi sb kuch lakin electricity bill mae koi farak ni pdra hi phle bhi itna hee bill ata tha
7.5 kva hi
Mera frequecy error aa rha hai, inverter off, frequency error
ikso kaise tigh krre ?
Input source me genset kar do
@@dsenterprises123 okay maine krr dia , yeh kislye hotta hai ?
Yeh genset ke liye hota hai kyunki genset ki frequency kam hoti hai
@@dsenterprises123 nehi Mera grid ka hi input tha. Firr bhi dikha rha hai. Voltage 260 and frequency 49.9 aur kabhi 50.1 Hz dikhata hai.
Khrab ho jata hi iska sara part dilhi si bhijta hai mahina laga diga
4kw utl solar panel kitna power dega and ek din me kitna unit banaega?
5kva solar pcu output power is 3700w, and unit generate 16-20 in a day
Sir Isme Har time main on he rhta hai ?
battery ka charge Kitna percentage charge hua hai hai kaise pata Karen
?
Voltage se
Battery low cut kaise set karte hai
Nhi kar sakte
Sir meray invotar me battery charger 0 solar power 0 no saplay display me yahi say lik raha sirf 000 kay karu on vi ho rha hai koi bi bati
Same bhai koi solution mila
Sir battery ka symbol half or full kab kab show karta he
Battery voltage ke aadar per
@@dsenterprises123 sir mene ek jagah 7.5kva/120v alfa + diya hr customer ko , vo bolte he sham ko jese hi sun light off ho jata he battery half show karta he or battery ka voltage 25volt rahta he us time
@@rajendrapagare4948 12.8 se uper wale voltage showing (floating) voltage hote hai ,not working voltages
Jo solar off ha to on kase krenga
Bhai hamari spv changing show nhi ho rha hai charging nhi ho rhi hai plzz contact me
False claim bay UTL IN smart mode
As per your tagline
Priority is like
1)solar
2)grid
3) Battery
But as per your flowchart in daytime MCHINE will work LIKE PCU MODE
HERE SECOND PREFERENCE IS BATTERY
That is it will work like
Solar -battery -grid
Here my 50%battery is drain as per flowchart it will sense grid ar 11.5v
But till my battery is 50% discharge
And supposed that my grid is also fails at same time when battery reached to 11.5v
At this condition i will have only 50%of battey backup as my battery is already 50%drain
Hello, battery equalization kaise karte ?
Reset button ko hold karke
@@dsenterprises123 - Thanks , Kitni der hold karna hai ? mujhe screen pe notification milega kya koi ki battery equalization ho raha hai ? thoda ache se explain kariye please. maine abhi abhi 5kv 48 v ka UTL ka Alpha invertor liya hai ..
@@parmanandsingh2023 display per battery equalizer mode likh kar ayega
Nice sir
Battery Equalize mode nahi aa raha sir ji
1.5 hp summersable chal jayegi
Yes
5kva 48 volt price?
9084646475
43000
@@ankushkharey505 dilwa do
Hapur se
@@ankushkharey505 really
Sir battery Equalize nahi ho rehe
Modol btaye
Utl alpha plus 5 kVa 48 volt ji
एकदम घटिया सर्बिस 2 महीना भी नही चला हैं
Bahut bekar ha utl k
Kyu teri jalti h kya utl se 😂😂