Auto and manual switch kaise connect kre. Mera motor plc output se operate ho rha hai, jisme ek circuit breaker hai, ek vfd hai, ek contactor hai, ek auto/ manual switch hai... Switch ka concept btaye ,kaise kam kar tree a hai ,auto /manual ke liye..please Baki cleare hai, circuit breaker se vfd ke l1,l2,l3 input per jayegi, vfd u,v,w output se motor ko, vfd ke 9 aur 5 no.trmnl se wire contactor ke no ya line input/output pe connect krenge. Ab contactor ka a1/a2 ko plc ke output se connect hai.plc jaise output dega contactor enerzige hoga, aur no se nc hoga, ya input se output ho kar vfd ke 9 no. Trmnl se nikli 24v vfd 5 no. Trmnl ko mil jayegi... contactor as a push button/on off switch hai.. Lekin selector switch bhi wo samajh me nhi aarha ... Can help me sir
Bro you have to use only one selector switch because if anybody press both switch in one time what will be happen, vfd get frd and Rvs signal that is why.... three mode selector switch is better....
Sir do dol moter hai sab auto system me pressure switch k throw on of hota hai ek bar me ek moter chalta hai dosre bar me dosra moter chalta hai es ka drowing kaise banega sir bataye
Woow !! Very useful
Nicely explained
Sir S120 vfd ke upload , download & Auto Tuning par bhi video banayiye with laptop
Sir please make video on macro setting with different application like 3 4 speed parameter
Qual lingua tú fala meu rei, parabens pelo video.
Sabhi drive ke videos aur parameters dikhaye sir ji
Sir please make videos on the topic of the interlocking of drive and starer
Sir ek video bnaeye auto /manual ka
Bhaiya Schneider VFD ka bhi poora batao pls
Great explain
Superb sir
Sir VFD pr aur vedio banaye
Ok
420 ka bhi ek video daal do sir
Auto and manual switch kaise connect kre.
Mera motor plc output se operate ho rha hai, jisme ek circuit breaker hai, ek vfd hai, ek contactor hai, ek auto/ manual switch hai...
Switch ka concept btaye ,kaise kam kar tree a hai ,auto /manual ke liye..please
Baki cleare hai, circuit breaker se vfd ke l1,l2,l3 input per jayegi, vfd u,v,w output se motor ko, vfd ke 9 aur 5 no.trmnl se wire contactor ke no ya line input/output pe connect krenge. Ab contactor ka a1/a2 ko plc ke output se connect hai.plc jaise output dega contactor enerzige hoga, aur no se nc hoga, ya input se output ho kar vfd ke 9 no. Trmnl se nikli 24v vfd 5 no. Trmnl ko mil jayegi... contactor as a push button/on off switch hai..
Lekin selector switch bhi wo samajh me nhi aarha ...
Can help me sir
Sir 2 wire with relay usme relay ke common me voltage kitna diya hai? , bcoz relay ke common jo voltage dege wahi relay ke N. O. se niklega.
Hi, I want to connect 440 with S7 300 plc using rs 485, can you please make a video on that with parameter setting and plc drive com setting?
In VFD micromaster 440 , Running feedback status not get properly to BMS what can I do bro?
Nice
Bro you have to use only one selector switch because if anybody press both switch in one time what will be happen, vfd get frd and Rvs signal that is why.... three mode selector switch is better....
Aap ek baar nye insttallation me practical kar ke dikhayeeye .
Bina practical ke mujhe kuchh samajh me nhi aata hai
Sir do dol moter hai sab auto system me pressure switch k throw on of hota hai ek bar me ek moter chalta hai dosre bar me dosra moter chalta hai es ka drowing kaise banega sir bataye
How many kilohms is the potentiometer to be used,5k or 10k ohms?
Any body have idea on parameters to configure the 3 programmable Relays on micromaster.
Drive par 2 wire chalana hai ya 3 wire chalana hai uska parameter dikaya nahi
Eeski manual milegi
ABB ...plase
Drive par 2 wire chalana hai ya 3 wire chalana hai uska parameter dikaya nahi