How to Change Impeller // Domestic Water Pump or Monoblock Pump
HTML-код
- Опубликовано: 12 сен 2024
- अगर आपके Domestic water pump या Monoblock pump से पानी का pressure कम देता है तो इस video देखें |
Domestic water pump पर मेरा ये video भी देख सकते है |
(1) अगर Domestic water pump जाम हो जाए तो - • अगर Domestic water pum...
(2) Domestic water pump // how to remove impeller without puller • Domestic water pump //...
CEILING FAN पर आप मेरा ये video देख सकते है |
(1) CEILING FAN - spin art in ceiling fan - • CEILING FAN - spin art...
(2) ceiling fan connection or single capacitor connection -
/ watch v=1EntT4BBgJA
(3) अगर ceiling fan का connection उल्टा हो जाए तो - • अगर ceiling fan का con...
(4) Ceiling fan coil winding - part 1 - • Ceiling fan coil windi...
(5) Ceiling fan coil winding - part 2 - • Ceiling fan coil windi...
(6) Ceiling fan connection - double capacitor connection in ceiling fan -
• Ceiling fan connection...
(7) ceiling fan का connection multimeter से कैसे check किया जाता है - • ceiling fan का connect...
(8) Ceiling fan जाम होने के मुख्य कारण - GOOD TIPS
• Ceiling fan जाम होने क...
(9) How many turn in ceiling fan coil -
• How many turn in ceili...
(10) ceiling fan connection of three wire - • ceiling fan connection...
(11) अगर ceiling fan का stator फंस जाए तो - GOOD TIPS
• अगर ceiling fan का sta...
(12) table fan या ceiling fan के slow चलने का मुख्य पाँच कारण - GOOD TIPS
• table fan या ceiling f...
(13) Ceiling fan - how to convert four wire into three wire -
• Ceiling fan - how to c...
(14) How to change ceiling fan capacitor -
• How to change ceiling ...
(15) कैसे जाने ceiling fan का coil short है - GOOD TIPS
• कैसे जाने ceiling fan ...
(16) Ceiling fan repair - part 1
• Ceiling Fan के Bearing...
(17) Ceiling fan repair - part 2
• Ceiling Fan के Bearing...
(18) how to open ceiling fan bearing -
• how to open ceiling fa...
(19) पंखा उल्टा घूमने के दो मुख्य कारण - GOOD TIPS
• पंखा उल्टा घूमने के दो...
(20) Ceiling fan का switch off है फिर भी Tester जलता है -
• Ceiling fan का switch ...
(21) Capacitor बदलने के बाद भी ceiling fan नहीं घूमता है -
• Capacitor बदलने के बाद...
(22) Ceiling fan में paper डालने के तीन तरीके -
• Ceiling fan में paper ...
(23) पंखा खरीदने से पहले , यह video जरूर देख लें -
• पंखा खरीदने से पहले , ...
नमस्कार सर जी आप ने जो दिखाया हैं बिल्कुल सही दिखाया हैं
Thanks
वीडियो मस्त लगा मेरे को
Thanks
thanzzz u sir aap k saare video ache h sab laga bhi h
बहत ही अच्छा विडियो बनाए आपने, दो legs के puller से impeller खोलने से केया impeller के दांत खराब हो सकता है ?
Maine apki all video dekhte hai apki video dekh kor maine ek fan ;ek motor ka problem solv kiya hay.
very good
भाई आपने इम्पेलर को सेट करने की सही जानकारी दी है जिससे पम्प वाटर प्रेसर अधितम देगा ये मुझे विश्वास हो गया है।
धन्यवाद 🙏🙏
🌹 Share this video
Namaste Sir very helpful video thank you.
आप इस Video को अपने सभी दोस्तों और रिश्तेदारों को Share जरूर करें
Good Sanju brother Thank you excellent video.
[PAKISTAN]
Always welcome
Very good 👍. Why impeller is getting demedg without touching back side or front side. Please answer
Good information video...👌👌 Thanq very much sir...👍👍
Most welcome
🌹Share this Video
Bohot tej dimag lagate ho sir aap nahi to ye ampelar leth machine ke Bina nahi khulta thanks sir
Excellant demonstration. Love from Pakistan.
Ok
J
Valeu amigo, vídeo muito bom.
Thanks you sir. 0.5hp monoblock pump wineding video banao na please sir.🙏🙏🙏
Thank you Sanjay Kumar Gupta for the video. I have concern for water pump. In our society, my house is at number 7. And only one water line. So first 6 house run their motors and get the water but I am unable to get water. Currently I am using 1hp Hitesh Water Pump. Can you help solving the problem?
Switch to Crompton Mini Master 1
Aap mere teacher hai sir...nice
Yr video is good and in detail. My 1hp crompton motor pressure is low now since one week. Two yrs back purchased. Servicing done now and seal, capasitor, impeller changed one by one but no pressure improvement. Even mechanic do not understand why is happening like this. No more parts left to change. No leakage & air gap. Can u suggest me on this. This is a mysterious problem and its a challenge to get answer. Awaiting for yr reply.
Change the NRV (non return valve)
bhai sab excellent demonstration 🤗👌👌👌👌👌
Thanks
Bahut hi saral tarike se ap bta diye
That pump was running for a long time with many air bubbles in the input feed line, leading to bad aeration and cavitation and so erosion of the blades in the centrifugal impeller.
* At 2:59, that is not the extractor/ puller one uses to pull off the impeller, as it will distort and warp it if it was going to go back into the pump. Those two holes in the impeller are meant to screw two pulling bolts in them and pull on them and push on the shaft. Those two holes are closer to the centre and they will pull the impeller from more solid location without distorting it.
* At 8:31 the gap between the impeller and the body of the pump between the input and output separator is too wide, and there will be a cross over loss from the high pressure to the low pressure side rendering the pump inefficient and will lose the head. There should be no gap there for maximum efficiency.
At 7:38 the impeller should not be hammered in, as that is too tight, I prefer it to be not tight and the impeller will settle in on the running surfaces on both sides when the last enclosure of the impeller is placed in position..
* At 9:41, that two pin plug should have been cleaned for a better contact. A squirrel cage induction motor takes a starting current of about 3 to 4 times the running current.
You are a genius.....I loved your detailing and I too agree with all your points !!
Kya water pump ko sewage pump mein convert kiya ja sakta hai.
Sir impeller fit krne k Bad line ment thik nahi hai kya kre
thankyou very much good topic👌👌👌👌👌👌👌👌👌👌👌
Sir apka video bahut achha lagtahe
Nice
Thanks
Best video
Please next video
Ok thanks
Nice video, how to increase water pressure.
Gupta ji water seal kitne type ke hote hai .1hp aur 0.5hp pump ko ek type ki water seal lagti hai Kya
C'est simple et profitable, merci.
Sir 0.5 motor winding achi hai bearing bhi thik hai fhir bhi motor garam hoti hai aur no load current 7amp leti hai kya karan ho sakta hai
Thanks so much sir good bless you
Nice video, thanks for sharing, Sanjay ji aap kahaa rahte hai aapke yahaa ye just dugune rate ka hai
धनबाद
Good Explanation
Thanks
THANKS G YOUR ALL video s Ajmal s from TAMIL NADU
M
Very very excellent
Snju bhai apki aawaz bhut achhi h
How much the price of this impeller?
thanks sir very helpful video👌
Aap Se JNnna Kahta Hun ki Aap Tul Pump Ka Winding Hath Se KAise Kurnga Achhi Tarah Se Tar Turn Pitch Me Kase Dalna Batane ka kirpa Karyn Danywad
Cancil
Very nice video thank you sir
आप इस Video को अपने सभी दोस्तों और रिश्तेदारों को Share जरूर करें
Sir agar motor coil winding ke hisab se garam horahahe toh kaise thik kare ? jaise 67 turn dene se motor garam horaha hai toh turn badhana padega ya ghatana padega ? coil ke resestance badne se garam hota hai ya resestancse ghatne se garam hota hai ? reply me
Turn बढ़ाना होगा
@@sanjugupta thank you so much sir for your reply
Esi vedio like nehin subscribe Bhi banta hai
🌹 आप इस Video को Share जरूर करें
अगर इमप्लेयर उल्टा बेड़ायेंगे तो क्या पानी के प्रेशर फर्क पड़ेगा ?
Motor awaz Karti h ahhi empilar change Kiya h १५ din पाहिले ??
Sir mere pass Venture Water pump machine hai 0.5 HP Wala To Muje Us machine Mai Zyada Pressure Chahiye Taki Mera 2 Floor ka building Hai to To 1000Ltr Ke Do Tank Hai to Muje US mai Zyada Presure Padna hai To Zyada Presure Wala machine Chahiye to Uske Liye Kya karna Padega
Sir.. मोटर का capaciter कब change करणा पडता है. मतलब के कोणसा fault आणे पे समझे की capaciter बदलना है.. इस वजह भी तो प्रेशर कम दे सकती ना.. Pls बतायें
Haat se guhmane pe chale tab
Kya water pump ki suction power jyada ki jasakti hai kya
Amplifire ka daam kitna padega
Impeller change karne ke baad Moter head me se air leakage ho rahi hai kay kare
Nice sir✌🏻✌🏻✌🏻
आप इस Video को अपने दोस्तों और रिश्तेदारों को Share जरूर करें।
Old motor water utharahahe or stop ho jatahe iska kya kare
Mere paas kirloskar ka 0.5HP ka motor hai use chalane ke turat baad garam hokar band ho jata hai or pani bhi kam deta hai... Kya karein ?
Sir mai impailer aur water sheal dono change kiya per tab bhi pani kam de rha hai kya karna hoga
Aur bhi koi tarika hai pani jada badhane ka to bataiye jaldi sir please
Ektham badiyaaaa👍👍👍
Thanks
Sir agar do amplar laga de to capacity duble ho jaygi?
No
Nice video sar
Hlo sir mere paas centrifugal monoblock pump h 0.5hp aise pani theek nikal rhi h, but tanki mei pani chadao toh 1-2 minutes k baad pani chadana bnd kr deti h kya kru koi suggestion do .......
Bagair chabhi nikalehi impeller nikal sakte hai kya aur bithate waqt bhi chabhi nahi nikalni padti kya
नहीं,चाबी निकालना तो बहुत ही आसान काम है
Sir gharelu motor ki winding jal jaye to dobara winding kaise krenge
The water pressure on the ground floor is fine, but it reduces by half on the first floor. Any suggestions?
Look for the pump curve if it is available for that pump and check if you can add bigger impeller in that pump which will give you higher head at the required flow rate.
Very useful Sir thanks
shivaraju 200011
Motor pani na uthanay ki problem ispe video banao
Iska shi polar btaye. Konsa le taking date tede mede ya crack nhi ho jroor btaye konsa shi hoga mere pas bi khatan 0.5 HP ka yhi mortar he seal Chang krni he
impeller rod ke sath loose fit hai, kya karna hoga?
Dada isko blade anticlockwise no clockwise ghumta hai please puchiye.
धन्यबाद सर
Good job videos
Thanks 🌹 Share this video
Nice feeling of imppular
शुक्रियाआपका ये वीडियो भाहुथ अच्चाहाई
Bhai speed slow ke kya kya karn ho skte ha
👍👍👍
3 साल पहले मैंने इंपैलर निकालने की कोशिश की थी लेकिन मेरे पास पुल्लर नहीं था तो इस वजह से मेरा इंपैलर भी खराब हो गया था क्या इसे निकालने का कोई देसी जुगाड़ भी है तो कृपया आप बताएं जिससे इमरजेंसी में इंपैलर को बिना पुल्लर के निकाल सकें।
Impeller ka kitna price hai o v to boliye sir ji
Can you tell me what is check valve in a pump.
Motor mein zam bhi nahi hai power dene sae rotate nahi ho raha hai heat up ho raha hai. kya karna parega Guptaj.
Water pump पर मेरे और भी video है , मेरे channel पर जाकर उन सभी video को देखें , शायद आपका काम हो जाए
Sir ujala ki motar hai uski body ki side ki line kharab ho gyi hai body fit nhi ho rahi kya kare batade plese
Sir mene abhi pani ki motor ki nai winding dalwai he...motor chalu krne k aad usme se धूँआ aata he or motor ki body bhi jyada garm ho rahi he..kya karan he iska..plz answer me
सर ये पुलर के बिना एम्पेलर नही निकाल सकते है क्या ? ओर इस पुलर टूल की कीमत क्या है
Sir Fan kaise lgaya jata h
Fan k Dant motor ki side krkey lgana h
Ya Dewar ki side Dant karney h motor fan k
hii
Abhijeet Singh
Btaya nhi sir g
Abhijeet Singh
Sir Pani wala motor h
Jo
10/15 minutes k Baad Band ho jata h Apne aap hi phir 5/10 minutes Band rakho phir chalta h
Pump saaf kart waqt kya dhyan dena chaiye sir
Sir.. Selingfen Puller kahapor milega? please sir reply me..
Hardware के दूकान पर
Agar Bering change karna ho or empeller thik ho to pher kese empeller nikalen ge
Bhut acha video sir
Thanks
Impeller ki key gum jaye tu uske bina laga sakte hai
Sir.mera.kilokar.moter.kds(12).ka. hi. Kya. Kds(13).ka.lmpeler.aega
Agar ampelar ek do teeth tut jaye to bhai motor pani uthayegi ya nhi
उठाएगी 🌹आप इस Video को अपने सभी दोस्तों और रिश्तेदारों को Share जरूर करें
Sir moter ka Jo pani phekta h pani khichne wala pankhi ka Dhaka milta h kya
हाँ मिलता है। जहाँ water pump का parts मिलता वही पर मिल जाएगा।
vry good sir...
Thanks
My Bajaj spectrum pedestal fan moving very slow
नल से 300 फीट पर पानी पहुंचाना कौन सी मोटर लगाएं
Very nice sir
Thanks
सर अगर एमपेलर को उल्टा फिट कर दे तो क्या होगा पानी उठाएगा या नहीं
नहीं उठाएगा
🌹 Share this video
Sir mujhe 1.5 inch motor ka impellor khol ke dikhaiyea na please mujhe aapka video bahut pasand aaya
मौका मिलेगा तो video बना दूँगा
Sir 1.5 inch 40mm pipe Wala motor ka impeller kholne Wala video banayea na
Sir hamre motar se pani atak atak ke aa raha to hame kya krana chahiye
Very good video sir I
Thanks
impeler ka rate kiya hai konsa brand Best hai
While purchasing new one all dimensions of impeller should identical otherwise it creates problem. Many time for new person difficult to get correct substitute. Shop keeper is generally not replace if some difference is there and for customer no use . Mechanic they can use somewhere to other customer.
Very nice video, both part, with this video i have repaired (complete shaft , bearing , seal etc) monoblock pump. I saved money. Thanks.
One request to you.
If possible, can you please make a video on repairing Arise Shallow Max ll - 1hp same like this with complete detail.
Ye 1 hp ki motor 1 hours me kitna unite khati hai
nice video. Sir apka electrical group he kya
Thanks
impeller our body mai kam gap rakhna hai ya jada ?
Video फिर से और पूरा देखें सब समझ में आ जायेगा
सर अगर इंपैलर की मक्खी गुम हो जाए तो मार्केट में मिल जाती है क्या अगर नहीं तो इसका सबकी ट्यूट क्या है
मिलती है