Closely coupled tees

Поделиться
HTML-код
  • Опубликовано: 4 июн 2022
  • All videos are for the intended use by gas safe registered engineers only, such procedures should not be copied or performed by non competent and unqualified persons.
    3T Gas Ltd - Heating and Boiler repair specialists in West Midlands
    www.3tgas.co.uk
    0800 9997870
    Instagram the_mental_gas_man
    MENTalk mental health advocate
    www.MENTalk.online
    Baxi ,Worcester Bosch , Viessmann, vaillant, ATAG, main , megaflo, ferroli, Ravenheat, navien , grundfos, wilo, Heatgeek, Intergas , talon , heatrae sadia , adey, boiler repairs , boiler servicing, central heating , boiler installation, new boilers , power flushing , vdi2035, magna clean , adey chemicals , faulty pumps , faulty pcb’s , diverter valves , balancing , efficiently , gas engineers

Комментарии • 30

  • @alfypierri8022
    @alfypierri8022 Год назад

    Very well explained. Thanks you

  • @craigwebster7405
    @craigwebster7405 2 года назад

    Nicely explained 👍

  • @jockster5525
    @jockster5525 2 года назад

    Thanks for your efforts 👍...

  • @sodig876
    @sodig876 Год назад

    Great video that's made it much easier to understand 👌

  • @aliatas6647
    @aliatas6647 6 дней назад

    In your experience, is one CCT enough to feed UFH & rads? or would you recommend two CCTs, one for each zone? Thanks for the video 😁

  • @valentinbelchev3301
    @valentinbelchev3301 Год назад

    Great video and explanation. Thanks 👍

  • @TDOWLP
    @TDOWLP 2 года назад

    Thank you. very good explanation.

  • @Skeletoncrew46and2
    @Skeletoncrew46and2 2 года назад +1

    Been and going on more courses about this.
    Your video has made it easier to understand than some of these course's.

  • @stewartharrod1706
    @stewartharrod1706 2 года назад

    Amazing video

  • @tethadam6678
    @tethadam6678 Год назад

    Great video

  • @leepickett3655
    @leepickett3655 2 года назад

    Really good this mate 👍

  • @grantbrown6089
    @grantbrown6089 Год назад

    If I was going to add a h/w circuit to this would that need its own pump too thanks and great video👍🏻

  • @randomcamerajunk6977
    @randomcamerajunk6977 Год назад

    Will you not have interplay between the 2 pumps on the one CCT? Just add a second pair of ccts for the UFH after the higher temperature rad ccts 🤔

  • @CommercialGasEngineerVideos
    @CommercialGasEngineerVideos 2 года назад

    You're back. I didn't realise. Lovely jubbly.

  • @henrybartlett1986
    @henrybartlett1986 Год назад

    Kimbo’s course is life changing.

  • @d.costacostagliola7298
    @d.costacostagliola7298 2 года назад

    Top video mate

  • @hufartd
    @hufartd 6 месяцев назад

    Instead of a non return valve on the radiator return (which I feel are very restrictive)
    I used a zone valve instead wired in parallel with the radiator pump to stop back flow while underfloor only was running.
    Do you see any issues with this?

  • @magicno001
    @magicno001 6 месяцев назад

    I guess your manifold in that plan is drawing its own water as in not an injector manifold?

  • @simonkay2273
    @simonkay2273 2 года назад

    Great video as always think I need to get on some of these courses.

  • @paulreece7148
    @paulreece7148 Год назад

    Hi, I’ve piped up a couple of systems after watching this. One question o have is, if the ufh manifold was say 15 metres away would you for an extra pump on that circuit to help with the flow?

    • @thementalgasman3tgasmainte317
      @thementalgasman3tgasmainte317  Год назад

      No you shouldn’t need the xtra pump it will work with out , unless it’s 15m of elbows and restrictions then you would need to give consideration to reducing that resistance

  • @mikecave4154
    @mikecave4154 2 года назад

    Could the normal method off boiler pump
    Doing upstairs rads and downstairs underfloor heating to the manifold on a normal s plan without close coupled tees there a lot out there without them

  • @jasonwhittle5008
    @jasonwhittle5008 2 года назад

    Did you wire the external pumps to the orange / switch live in wiring centre mate 👍

    • @thementalgasman3tgasmainte317
      @thementalgasman3tgasmainte317  2 года назад

      On this occasion I wired the pump to the brown on the zone valve as the switch live back from the UFH would energise the radiator pump when there is no demand

    • @ginola602
      @ginola602 Год назад

      Great video !

  • @joncoke8208
    @joncoke8208 Год назад

    GreT video
    Mate how
    Much r these courses roughly? Also recommend any breakdown courses you recommend?

    • @joncoke8208
      @joncoke8208 Год назад

      Also
      Are close
      Coupled
      Tees instead of
      Llh