Ur channel......great sir ......only this channel....in RUclips electrical engineering...subject because honestly hard work..........so 10000000000 like 👍more than......
Yes, but as there is particular options are given and mentioned domestic load so 1ph 2 wire is correct and if there had been an option such as 3ph-4wire then it'd be an absolute correct.
Very helpful video Thank you I want to give one suggestions that in question 11 most severe fault According to given option u r correct i.e. 3 phase fault But if Single line to ground fault on terminal of generator is given in options that is the most severe fault in power system So plz work in this area that what are other possibilities of option that will really helpful for the students
Good video,but guy wire is not the proper word,it's stray wire which is used in electrical engineering to give SUPPORT TO ONLY THE LAST POLE & THE POLES FROM WHERE THE THE LINES ARE TURNED SLIGHTLY TOWARDS LEFT OR RiGHT,ALL POLES ARE NOT HAVING STRAY WIRE OR GUY WIRE,while voltage level is increased for the transmission lines to reduce the current,as according to p=√3vicos phie voltage & current r inversely proportional to each other,so by increasing the voltage level of the power transmission through transmission lines,the current flow is reduced,hence the heat dissipated due to high current is reduced, subsequently reduces the transmission losses,also the highest transmission voltage level used in India currently is 800kv DC for HVDC TRANSMISSION LINES USED FOR 6000MW OF POWER TRANSMISSION FOR THE DISTANCE OF APPROXIMATELY 1700 KMS,I AM A SENIOR ELECTRICAL ENGINEER IN PGCIL
Thank you for your kind words, I genuinely appreciate your time explaining this in the comment section. I too know the technical name for the guy wire as stray wire but just this question was asked in one of the examinations I explained it likewise. Keep posting your valuable suggestions.
Buchholz relay is a type of oil and gas actuated protection relay universally used on all oil immersed transformers having rating more than 500 kVA. Buchholz relay is not provided in relays having rating below 500 kVA from the point of view of economic considerations.
Sure Pradeep, Some of the sessions are already uploaded on the channel. Soon I will be uploading the theory sessions on topics which you have mentioned with separate MCQ related to it. Stay tuned and DO share.
2:33 Q.3 Highest Transmission Voltage In India - 765kv OK ,but Sir Kaha , Konse State Me , Kaha Se Kaha Tak , Orr Konsi Company Transmit Karti Hai, Kitne KM ka Transmission Hai , Ye Sab Bhi Discuss Karte To....Bahot Hi Better Rehta....💯🇮🇳📍🤔 And IN HVDC Highest Transmission Line = 800KV💥
In question 11, single phase fault is more severe at the alternator terminals than 3 phase fault. As the fault location moves away from alternator, three phase fault becomes more severe
Correct. The question is indeed about the power system.& single phase fault is more severe at the alternator terminals is too correct at its place. Stay tuned and DO share.
@@Srinivasu222 Buchholz relay relies on the fact that an electrical fault inside the transformer tank is accompanied by the generation of gas and if the fault is high enough it will be accompanied by a surge of oil from the tank to the conservator. Here in even though oil is working medium but the relay actuates due to the production of the gas inside the transformer. Hence, Buchholz relay is gas actuated relay.
@@Srinivasu222 I hope you understood the concept well and I appreciate your question comprehension from my video, Do comment in my further sessions too if you have any doubt. Do share and stay tuned.
Sir junior engineering exams k liye konse author ki book best rhegi please btaiye jisme lagbhag saare subjects mil jay... Please help for God sir 🙏 bhot pareshan hu ise leke
Sure Mayank, I have already seen your comment but due to unavailability of time it got late. I would suggest you to start preparing from fundamentals book like B.L. Thereja RK Rajput and so, See kindly try to gain some fundamentals before going for the mcqs which will help you to get understand questions after reading theory. Kindly Stay tuned I will make one session on How to Study specially for electrical students.
Respected Sir, In question no 9 i think it is wrong option because it is service main which connect the consumer to the to the distributor, if i am wrong then correct me thanks.
Indeed, but the question here asked is different whatever you said is correct we generally do connect domestic loads by service mains but in the question TYPE of the distribution system is asked. Stay tuned and DO share.
Buchholz relay relies on the fact that an electrical fault inside the transformer tank is accompanied by the generation of gas and if the fault is high enough it will be accompanied by a surge of oil from the tank to the conservator. Here in even though oil is working medium but the relay actuates due to the production of the gas inside the transformer. Hence, Buchholz relay is gas actuated relay. I hope this will clear the question. Stay tuned DO share.
Yes, Rajesh I have uploaded topics which are important with respect to all state examination, you may prepare those videos if something left kindly comment down the topics which you want more to existing sessions.
See Kishor, these questions are taken from some of the reference books some are created according to the syllabus given by official BMC page. These are not previously asked questions. These questions are set and followed by syllabus only. Stay tuned and Do share.
Ur channel......great sir ......only this channel....in RUclips electrical engineering...subject because honestly hard work..........so 10000000000 like 👍more than......
So nice of you Manish, Kindly DO Share this session with your friends.
Well explanation sir... very helpful. Good job..jai hind...!!!
For 9th question I think the answer is 3 phase 4 wire system. Since we can take either 3 phase or 1 phase supply for required loads.
Yes, but as there is particular options are given and mentioned domestic load so 1ph 2 wire is correct
and if there had been an option such as 3ph-4wire then it'd be an absolute correct.
@@ElectricalEngineeringMCQs thank u sir
Sir .bahaut achha lagta hai apka teaching process.thanku for good job.
Most welcome Khokan Jena, Kindly DO Watch our recently uploaded sessions as well and DO Share them with your friends.
Very helpful video
Thank you
I want to give one suggestions that in question 11 most severe fault
According to given option u r correct
i.e. 3 phase fault
But if Single line to ground fault on terminal of generator is given in options that is the most severe fault in power system
So plz work in this area that what are other possibilities of option that will really helpful for the students
Thank you Ronak for your valuable feedback, I will surely do the same for upcoming sessions. Stay tuned and DO share.
@@ElectricalEngineeringMCQs most welcome dear
Jo aap bol rhe hai wo Generating System ke liye hota hai.
Thanks for this watching this for my msbte ( ept )online paper
Most welcome 😊
Aapka consept mind me jaldi jaha h. so thanks.
bluchholz relay are gas and oil actuated . not a only gas actuated .
but sir your explanation is good
Sb smjh aara sir thank you so much sir Nov m uppcl je ka exam h wanna crack it plz suggest us the strategy??
Sure.
Yes sir pls give question related uppcl je
Good video,but guy wire is not the proper word,it's stray wire which is used in electrical engineering to give SUPPORT TO ONLY THE LAST POLE & THE POLES FROM WHERE THE THE LINES ARE TURNED SLIGHTLY TOWARDS LEFT OR RiGHT,ALL POLES ARE NOT HAVING STRAY WIRE OR GUY WIRE,while voltage level is increased for the transmission lines to reduce the current,as according to p=√3vicos phie voltage & current r inversely proportional to each other,so by increasing the voltage level of the power transmission through transmission lines,the current flow is reduced,hence the heat dissipated due to high current is reduced, subsequently reduces the transmission losses,also the highest transmission voltage level used in India currently is 800kv DC for HVDC TRANSMISSION LINES USED FOR 6000MW OF POWER TRANSMISSION FOR THE DISTANCE OF APPROXIMATELY 1700 KMS,I AM A SENIOR ELECTRICAL ENGINEER IN PGCIL
Thank you for your kind words, I genuinely appreciate your time explaining this in the comment section. I too know the technical name for the guy wire as stray wire but just this question was asked in one of the examinations I explained it likewise. Keep posting your valuable suggestions.
Guy wire hota hai bhai
Very nice teaching sir..
Thanks and welcome
Good video,,your knowledge is best 👍👍
Thank you sir... Very nicely explained the terms...
Aap ka jo mcq question hia baut easy rhte tora ghumke questions bnae jho exam fas jate student
Thank you sir..... upload video about induction motor
Kindly Visit the channel for Induction Motor MCQ. Stay tuned and DO share.
Sir 14th question m apne kha ki reactor hm sirf series m use krte h pr sir reactor to 2 type ke hote Hai 1.series 2. Shunt reactor ?
Yes it depends It will be hard to explain here shubham but dont worry I will consider this question once again.
Sir very usefull
Thanks and welcome
Good explanation thanku
sir keep educating students ...trust me you will achieve something big.....
So nice of you Aditi, Thank you for your kind words. DO Explore our recently uploaded sessions and Follow our Non Technical Channel COACHIFY As well.
Thank you sir ji ♥️
2-3 nhi aare the Baki sab kar liya ....
Good question series sir 👏
Thank you so much Madhusudan, Kindly DO Share this session with you friends.
Thank you sir for this knowledge .. ☺️ 🙏
Buchholz relay is a type of oil and gas actuated protection relay universally used on all oil immersed transformers having rating more than 500 kVA. Buchholz relay is not provided in relays having rating below 500 kVA from the point of view of economic considerations.
Gud job sir thanku u so mach
Accha Bolte ho..
Very very thankful sir
Kindly DO Share this session with your friends
U hv taught well sir. So on plzz update about dc motor, Generator, alternators and transformers lessons with a brief explanations. Thank u
Sure Pradeep, Some of the sessions are already uploaded on the channel. Soon I will be uploading the theory sessions on topics which you have mentioned with separate MCQ related to it. Stay tuned and DO share.
@@ElectricalEngineeringMCQs thanks for the ur well courtesy of virtue sir.
I have done some on my channel
Sir question 6 answer should be option C because it is used as a earthing also in TL
Thank you for your response Shivam, Kindly Stay tuned I will review and rectify the same.
Sir estimation and costing mcq banaiye please
Any study material available in EEE brances sir?
Very good
Sir ji ...app all options ke bare me btaya kro kha kha used hote hai..
proper ..perfect
Stay tuned for more such sessions and DO share.
In question no. 8, star m current same होता h naa ki root 3 times se ghat jata h... Correct me if I am wrong sir
Video bahot acca tha sir
Sir, Electronics engineering students ke liye bhi video bnaiye.. for job placement purpose..
Sure. Stay tuned for upcoming sessions.
Yes
2:33 Q.3 Highest Transmission Voltage In India - 765kv OK ,but Sir Kaha , Konse State Me , Kaha Se Kaha Tak , Orr Konsi Company Transmit Karti Hai, Kitne KM ka Transmission Hai , Ye Sab Bhi Discuss Karte To....Bahot Hi Better Rehta....💯🇮🇳📍🤔 And IN HVDC Highest Transmission Line = 800KV💥
Thanks Sir
thanks alot sir for ur valuable time for us. superb work on electrical engineering mcq
Thank you so much Ankur for your kind feedback, Kindly DO Explore our recent sessions as well and Share them with your friends.
wonderful sir ....upload more videos on different electrical topics.... thank u sir.
.
Stay tuned for more sessions and DO share.
Apki teaching b achi lagi sir
Thank you Siddhant for your valuable feedback. Stay tuned for more suggestions. DO share.
Sir plz make video on DMRC syllabus based MCQ
Sir ye konse book ap follow karte hn kindly name btae please
Great sir
Thank you Awlesh, Kindly DO Share this session with your friends.
Sir plz make a video on ac terms
Excellent.
Plz continue the good work
I appreciate your kind words Utkarsh, Stay tuned for more sessions and DO share.
Thanks you sir for electrical video ..
Most welcome Parameswar, Stay tuned and DO share.
In question 11, single phase fault is more severe at the alternator terminals than 3 phase fault. As the fault location moves away from alternator, three phase fault becomes more severe
Correct. The question is indeed about the power system.& single phase fault is more severe at the alternator terminals is too correct at its place. Stay tuned and DO share.
Thank you so much sir 🙏🙏
Most welcome
Thanks sir sir. Its very helpful
Most Welcome, Do share and stay tuned.
Sir traction system par ek video banaiye please
Sure Kaushal it is indeed a very new topic I will upload the same.
@@ElectricalEngineeringMCQs Thank u very much☺
Nice sir
Thank u.. Very much..very useful.. Pls continue..ur students are awaiting .. Post video consisting msq qsns on electrical machine
read my comment,it will suggest u the limitations of this video,I m an senior electrical engineer in PGCIL
Always welcome, kindly check out channel videos for machines MCQ and further mcqs are on the way stay tuned and Do share.
Thanks 👍
Welcome 👍 kindly DO Share this session with your friends.
Thank u sir.. Ab halltiket aa gaye BMC ke to ab jada se jada important mcq ki video banao sir plzzz.... Must include more mechanical questions
Sure.
Sir .. make explanation vedio on electrical fundamental which mcq you provide earlier
Sure.
Verry useful
Thanks a lot
Sir question 20. Buchholz relay is oil operated relay sir
The answer is correct i,e. gas actuated relay kindly do crosscheck.
@@ElectricalEngineeringMCQs I strongly oppose this... Kindly check and update sir
@@Srinivasu222 Buchholz relay relies on the fact that an electrical fault inside the transformer tank is accompanied by the generation of gas and if the fault is high enough it will be accompanied by a surge of oil from the tank to the conservator.
Here in even though oil is working medium but the relay actuates due to the production of the gas inside the transformer.
Hence, Buchholz relay is gas actuated relay.
@@ElectricalEngineeringMCQs ohhh super explanation sir... thank you so much
@@Srinivasu222 I hope you understood the concept well and I appreciate your question comprehension from my video, Do comment in my further sessions too if you have any doubt. Do share and stay tuned.
Thanks sir, great job.
Always welcome Ranjeet, DO share and stay tuned.
Thank you sir useful la irukku thank you
Always welcome Devit. Stay tuned and DO share.
Sir junior engineering exams k liye konse author ki book best rhegi please btaiye jisme lagbhag saare subjects mil jay... Please help for God sir 🙏 bhot pareshan hu ise leke
Sure Mayank, I have already seen your comment but due to unavailability of time it got late. I would suggest you to start preparing from fundamentals book like B.L. Thereja RK Rajput and so, See kindly try to gain some fundamentals before going for the mcqs which will help you to get understand questions after reading theory. Kindly Stay tuned I will make one session on How to Study specially for electrical students.
@@ElectricalEngineeringMCQs sorry sir for disturbing you.... And thank you so much❤😊💖
I think in question number 11. Most severe fault on the Power system is " SINGLE LINE TO GROUND FAULT (LG) TYPE.
Most severe means dangerous bro
Bhai most severe fault on PS is 3 phase SC fault
And Line to ground is most severe for Alternator
@@8145akshay absolutely bro as the location of the fault increases from the alternator , the 3 phase sc fault becomes more severe.
LG fault is most frequent
Thank you sir
Sir ssc je ke liye kon sa book Acha hai
Nice explanation sir
i'm glad Deepak. Stay tuned and DO Share.
Sir I like Ur Teaching.....
Tottaly Fab
.......
This means a lot that my teaching is working for you, I appreciate your kind words Shubham and tuned and DO share.
Sir please, mcq questions hindi me b banaaiye
Sure.
सर नाईस
Hi sir my language Tamil but I understand your speech
Thank u sir for good knowledge
I appreciate your kindness. Stay tuned and DO share. also a latest video of this chapter is uploaded on the channel do check it out.
Good nice
Sir u r a great job.........thnks sir...
Thank you, Amit. Stay tuned and DO share.
Related electrical mcq please make video for ssc je
Sure Dhananjay I have already uploaded sessions for SSC JE Kindly DO Watch them and share it with your friends.
Bhai Electrical Engineer Gov Job me puche Jane Wale Qeutions karao please 🥺
Thanks🙏🙇
Energy meter regarding MCQ please
Please take 100 mcq on each topics
Nice
Respected Sir, In question no 9 i think it is wrong option because it is service main which connect the consumer to the to the distributor, if i am wrong then correct me thanks.
Indeed, but the question here asked is different whatever you said is correct we generally do connect domestic loads by service mains but in the question TYPE of the distribution system is asked. Stay tuned and DO share.
I have a doubt in 20 th question sir, buchholz relay whether it is gas or oil and gas actuated? Some where i saw it as oil and gas actuated
Buchholz relay relies on the fact that an electrical fault inside the transformer tank is accompanied by the generation of gas and if the fault is high enough it will be accompanied by a surge of oil from the tank to the conservator.
Here in even though oil is working medium but the relay actuates due to the production of the gas inside the transformer.
Hence, Buchholz relay is gas actuated relay.
I hope this will clear the question. Stay tuned DO share.
MCQs achche hai sir
I'm glad to hear the same.
Please complete the basic electrical syllabus for ssc je and uppcl je exam
Sure.
Gret sir be continued sir
Sir I think.. q. 20 ..
And is c
The answer is correct. i,e it is gas-operated relay.
B is correct
24th question underground cable
23/25
Tq so much sir
Sir good knowledge of electrical sent any vedio
Please go for hard mcq... I need those quick
Sure.
Sir which type used the reference books plz sir names the books
Sure. I will explain a detailed session on it very soon.
Q. 9 ka answer C option hoga
Sir make videos on all topics before exam
Sure. Do watch my playlist specially made for BMC Exam on my channel it has all the topics needed for exam.
Earthing ke liye GI wire use karte hai na..??
Hard drawn bare copper wires are generally used for better electrical conductivity.
@@ElectricalEngineeringMCQs k...thanks for your time
Ap wahe ans parha karin jo thek hota hy options ma, is sy vedio mazid kam tym ma pori hojai ge r log ziada like krn gy
T/f at generator connection plz explain
And 4 type of 3Φ connection t/f use
Sure, Vishnu Thanks for your kind feedback DO Check out our recently uploaded sessions on the channel and Share them as well.
Nice class sirr
Dear sir please provide basic questions of on/off load isolator, bus bar , computer Integrated manufacturing, automation,
Sure Manoj, a New video on Manufacturing Planning &
Control will be published today. Do share and Stay tuned.
For the BMC exam how many month current affairs prepared??Plz tell
Previous 4 Months thoroughly.
Sir mp JE ka prepare bhi krwwate hai kya (mp electric bord JE)
Yes, Rajesh I have uploaded topics which are important with respect to all state examination, you may prepare those videos if something left kindly comment down the topics which you want more to existing sessions.
Super sir
I'm glad to hear the same Pramod. Stay tuned, DO share and also do watch its next session which was uploaded on the channel recently.
Thank you sir!
But sir, these MCQs are new or previous exam paper or taking as it is from any book like mehta, khurmi and so..?
See Kishor, these questions are taken from some of the reference books some are created according to the syllabus given by official BMC page. These are not previously asked questions. These questions are set and followed by syllabus only. Stay tuned and Do share.
@@ElectricalEngineeringMCQs x
@@poojakhadkikar7385 thanks
Sir.. Can u plss suggest book for msedcl je exam..??
J b gupta and vk mehta