    @AngelasTravelAdventures 2 года назад +19

    18 year pediatric/neonatal therapist here 🖐🏾 the correct equation for a *cuffed* tube is age/4 + 3.5 and *uncuffed* is age/4 +4 .

    • @johnmueller3594
      @johnmueller3594 2 года назад +2

      Came here to say the same thing. I don't have the experience you do, but according to the 2020 AHA PALS card in my hand, I would have to agree with you!!!

    • @JF-ei9qk
      @JF-ei9qk 9 месяцев назад

      I came here looking for that correction

  • @HealthEdSolutions
    @HealthEdSolutions  3 года назад +2

    Thank you for watching! Please hit the like button if you enjoyed the video lesson. Feel free to leave comments if you have questions or feedback. We will try to answer them as soon as possible.
    Watch the entire Megacode Series Playlist here:
    ruclips.net/p/PLJ5kKhwVxA5LWvUYUzhtZIAFDKFibCiZp
    Check out these other great lesson playlists from our Channel:
    👉 Understanding and Interpreting ABGs: ruclips.net/p/PLJ5kKhwVxA5J9q3KXz-w5Er6itwzIriMw
    👉 One Quick Question Series: ruclips.net/p/PLJ5kKhwVxA5JBIokh4ddyRWelvnXlRtcQ
    👉 ECG Rhythm Review: ruclips.net/p/PLJ5kKhwVxA5LlDt9S-venJPYWNN7_TSEX
    Visit our website for 100% online certification courses in ACLS, PALS, NRP, BLS and more. We also offer free practice exams, flash cards, study guides and other free educational materials:
    🌍 www.healthedsolutions.com

  • @wyomusician
    @wyomusician 3 года назад +6

    Great video! My only constructive feedback would be regarding your slide on depth of ETT insertion. I believe you meant to measure the depth of insertion in cm not mm.

  • @kitpesec1536
    @kitpesec1536 3 года назад +2

    Great presentation))
    Like ALL your videos)
    Thank you so much!

    • @HealthEdSolutions
      @HealthEdSolutions  3 года назад +1

      Appreciate the feedback Kit! Keep watching as we have many more to come :)

  • @dr.abdullahmohsen2097
    @dr.abdullahmohsen2097 3 года назад +2

    Super like
    Amazing
    Thank you for your great job

  • @sidhesh3570
    @sidhesh3570 3 года назад +4

    Depth should be 15 cm, not mm

  • @stephenviggiano1610
    @stephenviggiano1610 7 месяцев назад

    ETT depth is always measured in centimeters from the central incisors, not millimeters.
    Of course, this was just a simple mistake but it is a massive one.

  • @waiki8223
    @waiki8223 2 года назад +2

    Good job but a few points.
    Q3: it’s not a “bad idea” to continue 100% oxygen, it’s dangerous and toxic, needs to be stated clearly
    Q5: A and D (the way your worded) are both correct. I’m sure you are aware that sinus tachycardia IS a sinus rhythm. Sinus only meaning the initial electrical impulse is generated in sinoatrial node
    Same as other comments on the more precision regarding ETT size and depth of insertion. You realize that 15 mm is about 2/3 of an inch. Ridiculous number.
    And it’s not a “positive pressure ventilation device” but a ventilator, providing CPAP mode most likely.

  • @susieharman2539
    @susieharman2539 2 года назад

    Informative

  • @drsumathikoduru9478
    @drsumathikoduru9478 2 года назад

    Children below 7y aren't incubated vth a cuffed tube , but u did in dis case,,,, can u please explain why ?

    • @helmetdoc
      @helmetdoc 2 года назад

      In the United States we mostly use cuffed tubes in the ER nowadays. They stay in place better and don't leak as much.