I have seen almost all of your videos. Your explanation regarding site work or IS codes is as very clear. I have seen many of youtube channels but your channel is awesome. You make everything so simple and clear. I have learn many things from your videos.
sir isme 135 degree hook beam ka stirrups me nahi he.higher dia main bars bhi he.uss case me 135 degree neglect karna he kya workability and proper bar alignment ke liye /??
Sir I m going to build my 3storey building of 40'×42' ,can I put hidden beams for my 29'×23' hall (attached dining) ? Or its mandatory to put normal beams ?
In top bars of beam lapping should be provide in mid span with spacing from both sides column l/3. Lapping should be 24d (d) dia of bar in top reinforcement and in bottom reinforcement lapping should be provided near junction of column and beam by 45d lapping and l/4 distance from face of column.
I hope this video helpful to all site Engineers, Please don't forget to like this video.
Sir Koi acchi si Checklist ho jo site pe use kar saku ...plz mail me on sayedfarzeen33@gmail.com
I have seen almost all of your videos. Your explanation regarding site work or IS codes is as very clear. I have seen many of youtube channels but your channel is awesome. You make everything so simple and clear. I have learn many things from your videos.
I am not civil engineering background...
But i love your channel......
Your information is awesome...
You will 1 million family soon...
Most underrated civil RUclips channel...
V good way to teach impressive & easy standard so well-done love from pak stay blessed factual services.
Thank you so much sir,
yours way of explanation & yours patience.
Very nice video... Is code ka mention karte Ho to bahot achha lagta he... Credibility jyada Ho jati he asking bro...
Beautifully explained , with drawing , on site, IS code.
This kind of site checking videos of urs are tooo awesome...i cant find any better videos then this videos of urs....keep uploading such videos....
Sir your all video is helpful for all of us.
Love u brother.love from pakistan❤❤❤
Thank you for making this video, please make a video upon column like this beam detail video
Good evening sir !
Greetings from Mumbai.
Your videos are very helpful and meaningful.
Thank-you.. 💐
Nice video bro. Good knowledge sharing
AP BHT ACHA SMJHATE HY APKI VIDEO BHUT ACHI HOTI ...
Thankyou sir your all videos are so helpful..
very useful video sir ... please upload more
sir isme 135 degree hook beam ka stirrups me nahi he.higher dia main bars bhi he.uss case me 135 degree neglect karna he kya workability and proper bar alignment ke liye /??
Sir I m going to build my 3storey building of 40'×42' ,can I put hidden beams for my 29'×23' hall (attached dining) ?
Or its mandatory to put normal beams ?
Ha aap kar sakte ho but us beam me reinforcement jyada dalna padega
It's very useful video
Sir u have cleared everything...but i hv 1 doubt beam me lap length fixed hota h as per is code or vary bhi krta h like in general notes ?
It's Fix as per Structural General Notes.
you r great sir,sir pls continuse beam checking/bbs ka link day dejey.thanks
Nice information sir.....👍
Nice video Sir... Also please make video on Post Tensioning Slab
I have posted question on slab. Kindly clarify the asked query.
Nice video sir
Sir column r/f aur verticality check,
Plaster check slab check Pai bhi video bnaye please
Sir please make a detail video on Mix design and mix ratio calculations
GOOD.
Super sir
In top bars of beam lapping should be provide in mid span with spacing from both sides column l/3. Lapping should be 24d (d) dia of bar in top reinforcement and in bottom reinforcement lapping should be provided near junction of column and beam by 45d lapping and l/4 distance from face of column.
Thank You Sir.....
Thankyou sir
Sir beam lap me bend nahi karah h stirrups ka cover nahi mile ha proper
As per is code spacer bar ka Dia kya hona chhahiye
Equivalent to Cover of Beam
Hello brother can provide me the design of building?
sir please make a video on bbs of staircase...??
development lenght column k centre me khtm hoga usko bhi column k l/3 pe end
Sir hooks 135 degree bend bhi nai h...nd where is cover block ?
🙏 🇮🇳 👍 😍
Sir billing engineer ko job searching ki video batein please
Sir, More Vedio Upload..
IS:13920
Beam ki stirrup hook sahi Nehi hai
But bottom lapping current