Carotid Protocol (Esther Collado, RN, RVI)

Поделиться
HTML-код
  • Опубликовано: 28 ноя 2024

Комментарии • 81

  • @jackelinmori1692
    @jackelinmori1692 3 года назад +64

    I have been doing Carotid sonograms for the past 7 years and I believe the ICA measurements she was getting was actually the ECA. If you noticed the ICA prox and ECA measurement are almost the same. Who agrees with me?

    • @chiqichiqi
      @chiqichiqi 3 года назад

      agreed

    • @julial3758
      @julial3758 3 года назад +6

      Oh good... not just my imagination.. I was thinking that is such a high resistance ica prox. & mid.. However, I think she got the correct ica when she did distal ICA.

    • @VivaLira
      @VivaLira 3 года назад +1

      Did you try tapp test for ICA/ECA to differentiate them?

    • @ReApEr789456
      @ReApEr789456 3 года назад

      I though the same, because of the end diastolic velocity

    • @MrJoeCt
      @MrJoeCt 3 года назад

      That's what I noticed too.

  • @0230Raveena
    @0230Raveena 10 месяцев назад

    Excellent. In my clinical rotations, the radiologist is always thankful for a cine loop of the CCA and vertebral to show direction of flow in both. This video is excellent for showing up to optimate the machine for vascular scanning.

  • @fabiomino3506
    @fabiomino3506 Год назад +3

    Woah, I barely started doing CCA protocol in my DMS class and this is all so crazy to me. The speed at which she does it, her left hand is so fluid, and it looks seamless.

    • @Greenfarmer25
      @Greenfarmer25 Год назад

      I have to have one of these done tomorrow and I hope the technician is good but I hope my results are even better!

  • @nagamallibanavath2598
    @nagamallibanavath2598 4 года назад +39

    I feel that you have done external as internal
    Please check once again

  • @vijaykansal3559
    @vijaykansal3559 4 года назад +19

    Nice presentation but confused a bit, Was that really internal carotid artery with high resistance wave forms in prox and mid ica?

  • @dhanakompremprabha7004
    @dhanakompremprabha7004 3 года назад +2

    Nice and clear demonstration, thank you.

  • @senaityohannes7515
    @senaityohannes7515 3 года назад +5

    Thank you for helping it was very clear, however, my only comment is that why the ICA was high resistant waveform.

  • @domenicogiannattasio9037
    @domenicogiannattasio9037 6 месяцев назад

    Beautiful video,i have learned many thinks,thank you for sharing it

  • @roinierdj
    @roinierdj 6 лет назад +18

    on rt ica prx and mid that you show it looks like it is eca instead, note the high resistant waveform on the doppler now for the rt ica dist looks good due to the low resistance waveform .....just my opinion

    • @roinierdj
      @roinierdj 6 лет назад

      @@kurtshellenback3337 ultrasound lovers

    • @kelseybrouwer4750
      @kelseybrouwer4750 6 лет назад +2

      exact like what I was thinking. sharp peaks with sharper sound for eca. ica shows fuzzier waveforms. good vid tho.

    • @xxibgdxx3089
      @xxibgdxx3089 6 лет назад

      i was thinking the same

    • @RanaaboodrrRana
      @RanaaboodrrRana 5 лет назад

      scoobydjj agree

    • @crizzameowly
      @crizzameowly 5 лет назад

      scoobydjj i agree! more like high resistance

  • @emrankamal7878
    @emrankamal7878 4 года назад +2

    In rt int carotid you obtain the external carotid

  • @DrAwad-nv4cu
    @DrAwad-nv4cu 5 лет назад +11

    -I WONDER HOW COULD SHE FIND PROXIMAL,MID, AND DISTAL ICA AT THE SAME SPOT AND UNDER THE CHIN.
    -THE LAST WAVE FORM IS DEFINITELY THE TRUE ICA WAVE FORM, THE PREVIOS TWO WAVEFORMS (PROXIMAL, AND MID ICA WERE WRONG)
    -SHE SHOULDN' HAVE POSTED THIS VIDEO.

    • @yadatj9250
      @yadatj9250 5 лет назад +1

      NFS Chanel yea I believe they were mid and dist ECA if anything

    • @smmangini
      @smmangini 5 лет назад +3

      in fact i thought they were ECA

    • @zsoltgarami4324
      @zsoltgarami4324 5 лет назад

      it is possible...

    • @nesrinslewa4815
      @nesrinslewa4815 5 лет назад +3

      I was wondering if anyone else noticed that as well. She definitely measured proximal ECA and mid ECA instead of ICA.

    • @mariana7556
      @mariana7556 5 лет назад +1

      I also agree that those high resistance blood flow were obtained from proximal and mid ECA, not from ICA

  • @GSXSF1k
    @GSXSF1k 3 года назад

    Is than IU22 Philips? Awesome machine!

  • @DJ-mix
    @DJ-mix 2 года назад

    how long it takes?

  • @sydbarrettmadcap
    @sydbarrettmadcap 2 месяца назад

    I thought ICA waveform was supposed to be low resistance? The waveform she was measuring looked high resistance. 🤔

  • @24hrs365
    @24hrs365 2 года назад

    Are both left and right sides normally checked or does your doctor need to request both be checked?

  • @1945erde
    @1945erde Месяц назад

    There was EXternal caritid artery from 2:48 to 3:30 and NOT INternal !!!

  • @connectionoflivesandinterests
    @connectionoflivesandinterests 4 года назад

    *Appreciate the video Thank you for Sharing. 🤗🤗🤗*

  • @chiqichiqi
    @chiqichiqi 3 года назад

    no transverse images???

  • @cimbom64mka46
    @cimbom64mka46 3 года назад

    Hello. Thank for explaining. Could you tell me please the normal PSV for the common carotid artery?

  • @RogerRamirez-RRstudio
    @RogerRamirez-RRstudio 3 года назад

    I remember creating this video. Esther was cool.

  • @王淼焱
    @王淼焱 Год назад +1

    好棒!

  • @SohelRana-hd7bl
    @SohelRana-hd7bl 4 года назад

    Thank you so much

  • @vincentlim5158
    @vincentlim5158 5 лет назад

    thanks a lot for this video

  • @newyorkguy158
    @newyorkguy158 5 лет назад

    If your doctor tells you that you have barely detectable thickening, what does this mean? Does it refer to plaque within the artery wall, or is there so much plaque, say 1.5mm thick that it is pushing slightly into the artery?

    • @haithambatarseh866
      @haithambatarseh866 5 лет назад

      you should only control it yearly
      .

    • @Commando303X
      @Commando303X 4 года назад

      I'd presume she might be referring to thickening of the tunica intima.

  • @GSXSF1k
    @GSXSF1k 3 года назад

    I appreciate showing ultrasound exams in RUclips but should not be completed as the others will fake their resume stating they have the skills to scan vascular when in fact they only learned from You Tube.
    I've had many experiences with such general Sonographers and their vascular examinations are qualified in labeling MALPRACTICE.

  • @kr-ql3fz
    @kr-ql3fz 3 года назад

    Thanks alot🖒

  • @oddfellow2182
    @oddfellow2182 4 года назад

    I HAD THIS done and asked if they can put it all on cd with sound and movie but they said its against state and federal law and they can only give me stills on cd

  • @revoltun
    @revoltun 5 лет назад

    Thanks a lot

  • @suzylekci9883
    @suzylekci9883 10 месяцев назад

    This is no way internal carotid artery you got them mixed

  • @1945erde
    @1945erde Месяц назад

    Philips iU22

  • @widadal-ali4384
    @widadal-ali4384 3 года назад

    ❤️

  • @-attemptingtherandom-2777
    @-attemptingtherandom-2777 5 лет назад

    thanks

  • @HyperHijabi
    @HyperHijabi 3 года назад +1

    only ICA distal was a true segment, the rest are wrong.

  • @vlaeldale
    @vlaeldale 4 года назад

    ВСА и НСА перепутали,женщина!Еще и учит!(

  • @1945erde
    @1945erde Месяц назад

    Philips iU22
    i can see what you want to hide

  • @rashaalj5927
    @rashaalj5927 4 года назад

    Thanks a lot

  • @collinsagbo6509
    @collinsagbo6509 3 года назад

    Thanks