PILE CAP DESIGN IN CSI SAFE AS PER IS 456:2000 AND DETAILING OF PILE CAP IN AUTOCAD.
HTML-код
- Опубликовано: 20 окт 2024
- #foundation_design #footing_design #pile_foundation #pile_cap
#Etabs #Csi_safe #Kartik_Saini
PILE CAP DESIGN IN CSI SAFE AS PER IS 456:2000 IN HINDI
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/...
couponCode = IAMTHEBEST
TO SUPPORT MY RUclips CHANNEL
UPI ID = Kartikgem3@okicici
Free Vastu Shastra Tutorials
• Vastu Shastra
notes
drive.google.c...
About this Video -
In this video, I explained how to design a pile cap in CSI safe software as per is 456:2000 and is 2911 and I also explained how to calculate no. of piles, spring constant, and detailing of pile cap in AutoCAD.
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/course/draft/3509014/?referralCode=5285FD0770E5E323E4CC
couponCode = IAMTHEBEST
sir it shows code expired
Hello Kartik
Thanks for sharing this new video. I really appreciate for your hard work.
Thanxxx sirji...your channel is really usefull initiative
Thank's again best of luck sir
Nice! Awesome work in the world! God bless my dear sir!
Very Informative... Thanks...
Hello bro, I got your punching shear at minute 34, why the punching shear column is 0.03 and the pile is 0.9, the column is hold big load from top to distribute to the piles, I think this come from shear force value determined by SAFE is not correct. pls explain
bro keep posting videos, your videos are amazing. one day will be flooded with subscribers.
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/course/draft/3509014/?referralCode=5285FD0770E5E323E4CC
VERY NICELY EXPLAINED
This helped a lot thank you
your tutorials are very useful...please upload video on complete design of multistorey buildings with frames being designed by ETABS, slab and foundation designed by SAFE...
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/course/draft/3509014/?referralCode=5285FD0770E5E323E4CC
You are doing wonderful work sir keep growing
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/course/draft/3509014/?referralCode=5285FD0770E5E323E4CC
Love you sir, please make video on g+3 building design in etabs completely please sir.....thank you sir
This guy is so intelligent
How about the shear reinforcement?? If the shear reinforcement is required in slab design display type, but the punching shear is okay (all is < 1), are we still need the shear reinforcement (shear links)?? thanks before
Very nice vedio thanks for uploading such vedio .. make single pile cap design vedio and its autocadd file
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/course/draft/3509014/?referralCode=5285FD0770E5E323E4CC
When clicking Imposed minimum reinforcement take ??
Working load capacity means ultimate capacity or safe capacity??
Make full lectute on desigen of multi column taken from etabs..plz sir
how to calculate spring constant ?
Pls give announcement regarding your next video or course. Pls try to upload videos atleast once in a week if possible
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/course/draft/3509014/?referralCode=5285FD0770E5E323E4CC
How do you calculate the expected settlement of pile? Geotecnical engineers provide us only the pile capacity.
Please upload pile cap design for wall
How to calculate spring constant. If it's not given in geotech report
Bhai or video banao naa pile cap ki
Bhai etabs me mode shape bhi design krna bta do .
How to calculate spring constant? If it's not provided in geotech report
Sir plz tell me if grade beam is in pile cap and used as plinth beam.
Pl. upload design of bored pile stem in excel.
Can you please reference to code where it is mentioned allowable settlement in pile can be 1% of pile diameter?
Dear Kartik Saini: Excellent demonstration. Please can you tell how to get SAFE SOFTWARE ?
getintopc.com/softwares/csi-safe-2016-free-download/
Sir can you please send dxf file of AutoCAD
shear wall & flat slab design please
Course title-RCC SLAB DESIGN AND DETAILING AS PER IS CODE 456 IN CSI SAFE AND CAD SOFTWARE.
www.udemy.com/course/draft/3509014/?referralCode=5285FD0770E5E323E4CC
Please check your mail after this session. I need your help regarding Raft foundation design. If it's possible.
How about the shear reinforcement?? If the shear reinforcement is required in slab design display type, but the punching shear is okay (all is < 1), are we still need the shear reinforcement (shear links)?? thanks before