Sir Jaise aapne kuch parameters ke name thode change karke btae he Unse bhut jyada benefit hua he Example 102: [02] customer configuration = Back-up saved parameters It is very helpful 👍 Thank you Please if possible similar simple language me baki parameter ke name bhi mention kr dijiye
Hello Sir, How i can enable my altivar312 conf mode? It's disabled. When I push the mode button its scrolling up and down between ref and mon. But not able to select conf.
Same time pr DRIVE ko PLC se bhi esko analog output Mill rha h or Potentiometer bhi add h usi time to VFD kisse speed control kregi PLC k analog output se ya Potentiometer se
Sir hmm Drive ko 3 alag alag speed pr control krna chahte h to kis parameters pr set kre speed Example If LI1 High = 100 RPM If Li2 high = 200 RPM If Li3 High = 500 RPM Ye function k liye kaise kre sir Please
Thanx Sathic Batcha for your Comment. According to my view both vfd are best for Fan and Pump application. The only difference is that the atv630u75n4 is latest (2016)model with more function and atv212hu75n4(2014) with lower function compare to atv630. If you don't require more complicated function then atv212 is best for you.
I am operating drive by remote on/off mode but want to change frquency from drive potentio meter what are parameter for changing frq from drive potentiometer
dear sir Schneider 610 modal ki drive hai Uske sath rpm meter connection karna hai drive me parameters kaise Kare to taki rmp meter par motor me rpm show Kare please parameter batai
Vfd display per fun time show kar raha hai frequency nahin a rahi hai fan time hatana hai to kaise kaise karen jisse ki frequency display per show karne lage
I will make a practical video on it in next week. Run command drv= 0(Keypad) 1(Terminal) . Frequency command Frq = 0 ( keypad) 3 (Terminal) Cm= common P1 = Fwd P2 = Rew Port VR = 10V AI = Variable CM = Analog common
Ek problem aa rhi h jaise forward comand Li1pr dete h aur pot full krte h tho drive pure rpm pr aane k baad rpm down hone lagte h aur 000rpm ho jate h reverse mai sahi chalti h please help me 🙏🙏
Sir Switch 1 : inch Switch 2 : run Switch 3 : stop 3 switch se ye 3 function ek sath nahi hoo paa rhe Schneider atv310 vfd ya khe reverse ki jgha Inch function chahiye If possible please reply
Inching(jog) ka direction change kaise karte hai sir please explain ? Mujhe start aur jog dono me reverse direction chahiye. Start ka toh 503 me ja k assign kiya isliye wo reverse me run ho raha hai par inching forward me hota hai reverse me kaise assign karu ?
@@niceelectronics9505 Dear sir i am working on it and I hava a problem that if my machine se off then its blower will not work on 50 hz it work on 10 hz or 5 hz so sir plz explain how the Jog input we used for it??
@@niceelectronics9505 Dear sir I assigned L13 Input from 505 and Connect no pb betweeen L13 and Comm of drive but still function is not run..please tell me what i will check??
Sir
Jaise aapne kuch parameters ke name thode change karke btae he
Unse bhut jyada benefit hua he
Example
102: [02] customer configuration
= Back-up saved parameters
It is very helpful 👍
Thank you
Please if possible similar simple language me baki parameter ke name bhi mention kr dijiye
Thank you bhaiya aapne meri or shankar dono ki noukariya bacha li... 🥳🥳🥳🥳🥳🥳
Sir apne ko display me rmp show dikhana chahiye kya karna hoga
It's very knowledgeable, please make a vedio with Fuji VFD
ruclips.net/video/qQVJ0LNqQls/видео.html
Thank you aapka program pasand aaya.
Very Useful for me sir...Thanku...
Thanx Dilip Patel For your Kind Response...
Good job sir ji,🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
Very nice sir..
Bhai ek num shooting &making this video
Sir how to increase and decrease motor speed without pot or by connecting digital input at Li3 and LI4, which parameter has to do
Very nice
Sir mujhe atv310 2 wire mode pe chalana h or frequency keypad we control karni h kya parameter dalna hoga plz btaye sir urjent
Video Mene full details me bataya he..
@@niceelectronics9505 usse nahi ho RHA sir sirf run keypad we ho RHA h
Very good
Good job
Hello Sir,
How i can enable my altivar312 conf mode? It's disabled.
When I push the mode button its scrolling up and down between ref and mon.
But not able to select conf.
Pahle se ek set ky ushe dusra program set kr skte hia ky...
Same time pr DRIVE ko PLC se bhi esko analog output Mill rha h or Potentiometer bhi add h usi time to
VFD kisse speed control kregi PLC k analog output se ya Potentiometer se
Average of Boath value will consider by VFD. But it can cause problem in PLC analogue output...
@@niceelectronics9505 thnku ❤️
Sir hmm Drive ko 3 alag alag speed pr control krna chahte h to kis parameters pr set kre speed
Example If LI1 High = 100 RPM
If Li2 high = 200 RPM
If Li3 High = 500 RPM
Ye function k liye kaise kre sir Please
Thank you very much
VFD ATV-310 ke baare mein basic se jankari dijiye. Thank you sir
www.se.com/in/en/download/document/EAV94277/
Thanks 😊 sir 👍
Sir parameters lock karne ke liye konsa perameter use kre
Atv 310 me relay on delay time ka option b h kya ?
Who is best drive in atv630u75n4 or atv212hu75n4 please answer me
Thanx Sathic Batcha for your Comment. According to my view both vfd are best for Fan and Pump application.
The only difference is that the atv630u75n4 is latest (2016)model with more function and atv212hu75n4(2014) with lower function compare to atv630.
If you don't require more complicated function then atv212 is best for you.
@@niceelectronics9505 thank you 😃
Give me your mobile number brother
09904670809
Sir ATV 320 model Schneider program pr ek video
nice boss
Hello SER ji vfd ki rpm 25 tk shai chelta h 25 se Jayda display on of krti h uppae btaoo serji
May be Internal hardware problem. Please repair it..
I am operating drive by remote on/off mode but want to change frquency from drive potentio meter what are parameter for changing frq from drive potentiometer
Please watch video carefully all programming are mentioned in it.
dear sir
Schneider 610 modal ki drive hai Uske sath rpm meter connection karna hai drive me parameters kaise Kare to taki rmp meter par motor me rpm show Kare please parameter batai
Please read manaual and set analog output according to your requirement.
sir EOT crane me used altivar31 me break control setting kai karege
Thanks sir
Good sir
Jordar
Great
Helo sir altivar 310 vfd me laga huwa cooling. Fan kiun .nahi chal raha hai
Agar drive ka internal Temperature certain level ke upar jayga tabhi fan start hoga..
Sir eski speed nhi eske ender wale port se speed nhi bed rhi to kya kerna pdega
Please check parameter mentioned in video.
Vfd display per fun time show kar raha hai frequency nahin a rahi hai fan time hatana hai to kaise kaise karen jisse ki frequency display per show karne lage
Par 802 (output frequency) par jakar jog dial press karo for a second.
agr aap l&t ki Cx2000 ka programming or terminal connection btaa skte hai to plzz share this
I will make a practical video on it in next week.
Run command
drv= 0(Keypad) 1(Terminal) .
Frequency command
Frq = 0 ( keypad) 3 (Terminal)
Cm= common
P1 = Fwd
P2 = Rew
Port
VR = 10V
AI = Variable
CM = Analog common
Ek problem aa rhi h jaise forward comand Li1pr dete h aur pot full krte h tho drive pure rpm pr aane k baad rpm down hone lagte h aur 000rpm ho jate h reverse mai sahi chalti h please help me 🙏🙏
Sir
Switch 1 : inch
Switch 2 : run
Switch 3 : stop
3 switch se ye 3 function ek sath nahi hoo paa rhe
Schneider atv310 vfd
ya khe reverse ki jgha
Inch function chahiye
If possible please reply
Hi
Sir ji ATV610D15N4 ki warig or paramitr kase dalte hai jana hai
Pot se minimum speed
42.0 se kmm nahi hoo rhi
Koon sa parameter check krna he sir
Please reply
Atv drive ko remote se controlling karana bataye
Nice
Danfos ki vfd commissioning ke bare bataye
Gud information... thank u.
please sir atv310 ki Jog speed up down parameters konsa hai
Jog Speed is fixed to 5HZ
Second speed ke liye muje parameter aur kaise setting karte hai wo kijiyega sir
Noise control ke liya kya parameter hota hai..?????
Inching(jog) ka direction change kaise karte hai sir please explain ? Mujhe start aur jog dono me reverse direction chahiye. Start ka toh 503 me ja k assign kiya isliye wo reverse me run ho raha hai par inching forward me hota hai reverse me kaise assign karu ?
Thank you sir
Sir puch switch se seed high or low karni ha parameters setting bhatae
Should I do inching fwd and reverse sir??
🎉
Sir pl shAre yaskawa 1000 vfd programming & wiring
ruclips.net/video/EP-zWIoMdCU/видео.html
Schneider vfd alarm ka video banaye sir please
Ok Thanx for your suggestions. Will try to make in upcoming week.
Sir, Potential se 25 HZ se upper frequency nahi ja rahi h kya issue ho sakta pls suggest.
❤
Atv12 ho.37m2 how is connection in motor and how is potential meter
Altiver 310 New VFD install kiya but motor bhut heat ho rahi hai please Gide me
Sir iski speed 80.0se upr leke jani he perameter bataye
sir how i can use jog function...plz explain
500- 505- JOG assign any input
Jog frequency fixed 5Hz
@@niceelectronics9505 Dear sir i am working on it and I hava a problem that if my machine se off then its blower will not work on 50 hz it work on 10 hz or 5 hz so sir plz explain how the Jog input we used for it??
Assign any jog input by 505 parameter and then connect a NO pushbuttons across jog assign input and your vfd common terminal.
@@niceelectronics9505 Dear sir I assigned L13 Input from 505 and Connect no pb betweeen L13 and Comm of drive but still function is not run..please tell me what i will check??
What is common terminal of your vfd.?
In New vfd at start it goes to 60 Hz then itself stop what will be it's cause and solution
bro drive ko Jaise hi supply dete h to R1a and R1c me continuity dikhata hai. Aisa kyu ? r1a to NO Hai
hello sir avt310 me F015ka error aa raha hai please help me
3 Output phases loss•
Motor not connected•
Motor power too low, below 6% of the rated drive current •
Output contactor open
Aewsome
Atv312 on karne ke bad 2 sekind drc lekha tata he fir band ho jati he kya karna chahiye batana sar please
Hi, I couldn't get the PID to control the speed via a 4-20ma sensor
ATV320 ko kaise karte h pls tell sir
Atv 320 ruclips.net/video/8ZDxK7nfpU0/видео.html
When stopping brake not working I tried all parameters plz help
Apka stop mode konsa set he..apki VFD me..Ramp to stop set Karna padega pahle to..
@@niceelectronics9505 i using atv 303 and Fuji frenic mini both has same problem can u tell me parameter for coast stop
Kya apki dono VFD Stop hone ke time par without braking resistor Overvoltage ki error deti he ?
@@niceelectronics9505 no any type of alarm dece.time 3 sec.
Then ap breaking resistor kyo use Karna chahte ho..
how to connect 2 nos NO/NC push button to operate one nos drive not : drive is as per your video
Sir motor mein supply nahin jaaye to kya setting karni chahiye
Sir mera company me mera nam chuna gaya hai vfd aur controller sikhne kelia
To delta .semens denforse ka bhi bataiye uske model ka jo basic funda
Next week se me firse other vfd ke video banaunga so watch my channel new updated video ...
Sir 310 model ki output supply nahni hota h,kese kare
Altivar 38 vfd how to connect 3 water pump via PLC control
Do you want to connect 1 vfd for 3 water pump. And do you want to maintain constant pressure.
Sir give more information of another drive para
Sir drive ko continue run karana h kese karege
Donfoss ki vfd pe kr ke bataye
Vfd me rely ki setig ke bare me bataye Waring bee
Please watch this Video on VFD internal Relay Setting Thanx
ruclips.net/video/VKUFkjvlyo4/видео.html
How to reset fault if occurred
Press Stop/Reset button after solving fault cause...
Thank sir
Mara Schneider vfd problem...F0 18.kaya Karu...
Apple breaking register program 4kw motor pls
Hello sir
In this drive how to configure Relay o/p through parameters
Check parameter 205
R1 assignment in manual..
Sir Atv12hu15m2 ka peramiter btaiye
Kis type ka wiring apko karna he?
Terminal mod conction
Isme 513 parameters kaise khole ji nahi khul raha
F015 aata hai ji kya kiya jaye
Connect motor to vfd and check it ohms
Shinder altvear 61 AI1 and AI2 and keypad remote 2wir 24 voltage operating please Hindi
Sir f020.bata raha ha kase kare
Refer to manual
Need connection diagram for pot and push button
Hello Sir, F020 likha hua aa rha hai kya kre
Schneider vfd overspeed f025 faut hai kya kare
Power on then speed automatic run
303 ki reel kese set kere
Supply on than speed automatic
Apki vfd ke run command ka wiring ko check kijiye..
Ser drive run nahi hota cod aa raha h F018
F018 motor short circuit ki error he apki motor check kijiye..
Aisa video kisine bhi nai banaya
- - 11 aisa indication ata hai..ye reset kaise kare
Ye indication ye indicate karta he ki apka input supply improper he agar apki input supply sahi he to aki vfd ke hardware me kuch problem he..Thanx
@@niceelectronics9505 thanx sir..bt agar hardware main kuch problm hai to kaise solve kare
Sorry isme excetly kuch kaha nahi ja sakata ki konsi board me problem he ....
Thanx sir..
Aur ek puchna tha
If have brake motor
Vfd programming ka PDF file hai sir
www.google.com/url?sa=t&source=web&rct=j&url=prom-electric.ru/media/ATV310_user_manual_EN_EAV94277_04.pdf&ved=2ahUKEwjr9uOYgZHrAhXq8HMBHe6bCs8QFjAAegQIARAB&usg=AOvVaw2PG6KzDTHcy9lLkN6cdigw
Run danay par a signal a rahta ha
Fault f09 and f25