The Microwave is tripping the breaker !!! (Troubleshooting)

Поделиться
HTML-код
  • Опубликовано: 11 сен 2024
  • How to troubleshoot and fix a faulty Frigidaire microwave.

Комментарии • 20

  • @allisondoot8104
    @allisondoot8104 Год назад +1

    THANK YOU! Everyone kept telling I was crazy for trying to fix our microwave and to just buy a new one. I spent $7 on the replacement part instead of $250 on a new microwave. Glad I saw the comment about the thermal switch being inaccurately diagnosed, but otherwise this was very helpful!

  • @jibbyleo
    @jibbyleo Год назад

    Exactly my problem/bad door micro switch.
    I’ve been holding on to cherry micro switches for years from my past line of work. Fit right in.
    Thanks for the info!!!!

  • @marsellmorris3204
    @marsellmorris3204 3 года назад +13

    When checking the second thermal switch, and you got no continuity, you said the switch was bad, and you were wrong. The second switch stays open until the microwave reaches a certain temperature and then it closes to prevent the oven from getting too hot.

    • @victorcontreras2551
      @victorcontreras2551 2 года назад

      So 1 open and 1 closed?

    • @ourkielectrical5984
      @ourkielectrical5984  2 года назад

      My mistake saying so.
      Thank you for your attention. Noted

    • @teamavenger007
      @teamavenger007 Год назад

      You saved my Microwave's life. I was worried my thermal was broken on the right because it doesn't have continuity.

  • @metalmike570
    @metalmike570 3 года назад

    Thanks I had a bad right side thermostat (I think that's what it's called). You made it easy to find.

  • @rahulreddy88
    @rahulreddy88 2 года назад +2

    Great that you fixed the issue but what are those faulty parts called? If we dont know we dont know what to ask or look for in the hardware store

  • @ap6462
    @ap6462 3 года назад

    Thanks for sharing your expertise. We'll done!

  • @anonymooh
    @anonymooh 4 месяца назад

    Isn’t the right bottom thermal fuse built purposefully not to have continuity ?

  • @alejandrobahena6065
    @alejandrobahena6065 2 года назад +1

    Sr. Where did yuo buy the parts and switch??

  • @JC-xc8rx
    @JC-xc8rx 2 года назад

    So basically you replace the second thermostat which was good, and the door switch which was bad.

  • @amagjr2003
    @amagjr2003 2 года назад

    2nd thermostat is normally open and closes to a certain temperature. You also didn't show that you've replaced the thermostat, why? Least you can do is make a follow-up video to rectify and prevent false information on RUclips.

  • @warrenpeas
    @warrenpeas 2 года назад

    this the only video that shows it might not only be the door switches it can also be the 3 round black thermostat controls
    . TEST THEM ALL. Test the 20A tube fuses too.

  • @thusithasenanayake9985
    @thusithasenanayake9985 2 года назад

    One thermostat is open and other one should closed

  • @harryrichmond9458
    @harryrichmond9458 3 года назад +1

    I have the same problem

    • @randymalak1730
      @randymalak1730 3 года назад +3

      The 2 round thermo switchs located on the bottom do not both have continuity. The switch on the right is normally open and closes at temps above 150 deg an turns the fan on.

    • @ourkielectrical5984
      @ourkielectrical5984  2 года назад

      @@randymalak1730
      Yes was my mistake when I said the right side one wasn't good.