Troubleshooting Ingersoll Rand Compressor (oil leak and heat issues)

Поделиться
HTML-код
  • Опубликовано: 10 дек 2024

Комментарии • 81

  • @renebertin5377
    @renebertin5377 2 года назад +1

    I have the same Ingersoll Compressor. I really wish I could fine my heating problem also and why it shuts down after 15 minutes. I removed all the metal panelling for it to cool better but still shut down. I’m starting to think that my problem is the inlet valve. Keep on making videos I really appreciate it

  • @nigeleharis5886
    @nigeleharis5886 3 года назад +1

    One of the only air compressor technicians here in Hawai’i. Thanks for this video brotha!

  • @jaymoney119966
    @jaymoney119966 8 лет назад +4

    I'm a generator mechanic from Chicago and have been wanting to make videos like this and you give me inspiration, keep them up and maybe you'll be watching mine soon

    • @bennycomptech3939
      @bennycomptech3939  8 лет назад +1

      jaymoney119966 it's so fun doing these videos I make no money doing them solely just a hobby for me if you get into it you'll enjoy it! And I will definitely watch your channel if you create content!😁

    • @johnestes7477
      @johnestes7477 6 лет назад

      Benny, are you working for IR or on your own?

  • @jamchan6436
    @jamchan6436 8 лет назад +1

    I like these compressors. I did a job a while back in Campbellsville Kentucky at The Ingersoll rand plant doing all the electrical work I got too watch The assembly of multiple Ingersoll rand compressors its a pretty cool place

  • @dlimms87
    @dlimms87 8 лет назад

    We worked primarily on Quincy compressors, but we worked on others as you do. On one call I was working on a QSI-235 . This machines components are mounted on a steel skid. The floor dry was at the level of the top of the skid the hole comp.end of the skid,and the skid is probably 8 inches high.😳 Thanks for your video!

  • @tiaandbuster
    @tiaandbuster 8 лет назад +1

    hey benny , another good one ..... it's great to see the videos coming again ...keep it up ..... love to watch someone good at what they do , and keep trying to do better ....... thanks for the great videos bud .......

    • @bennycomptech3939
      @bennycomptech3939  8 лет назад +1

      Lloyd .Haight thanks man I appreciate that right now I'm working on the wobbliest scissor lift in the world at a Walmart video will come soon tomorrow need to get supplies to finish the job

  •  5 лет назад +1

    I am worker repair.Your Video help me too good my Job ....👍👍👍👍

  • @pancho20006
    @pancho20006 8 лет назад +9

    don't leave me hanging like on the novelas now u got to tell what happen to that compresor lol

  • @maxjackson2523
    @maxjackson2523 5 лет назад

    Good video I'm working on one I'm my shop. Same symptoms save for the breather isn't wet its the tiny blue like that's quick connect on one end and compression fitting on the other. Pre filter is Definetly restricted.

  • @bennycomptech3939
    @bennycomptech3939  8 лет назад +4

    Everybody's comments are so greatly appreciated I'm glad you all enjoy my channel it's far beyond nice to know that my work and my effort to make these videos is worth it!!

  • @whirlwind8825
    @whirlwind8825 Год назад

    Hi ..where is the thermal valve located on this model

  • @lovetacoma8604
    @lovetacoma8604 3 года назад

    Thank you for your sharing.

  • @workhardtv2071
    @workhardtv2071 4 года назад

    hello sir what possible problem of air compressor screw type turing running good or loading but, unload the oil come outside into intake

  • @danburdgick8498
    @danburdgick8498 2 года назад

    Which direction does the IR inlet valve deflector get installed? Bend towards casting or towards valve?

  • @Biggbird1717
    @Biggbird1717 5 лет назад

    I’m having the same issue as In the video but it does turn back on after gets really low.... and I have oil in my air filter as well

  • @fivestring4653
    @fivestring4653 4 года назад

    Great video man

  • @andywheeler9583
    @andywheeler9583 8 лет назад +1

    Good video keep them coming

  • @danburdgick8498
    @danburdgick8498 3 года назад

    What about excessive oil coming out of the scavage line

  • @NoGo90
    @NoGo90 8 лет назад +1

    Liking these videos, could you do a video on your repair kit? Maybe you have already...

    • @bennycomptech3939
      @bennycomptech3939  8 лет назад

      NoGo90 my repair kit? You mean the bag I'm using In the video?

  • @nickmeadtanks
    @nickmeadtanks 5 лет назад

    Hi benny I run a lngersol rand 7/41 towable compressor for sand blasting army tanks my guys told me today it was real hot and wasn’t pushing air. Surprise surprise no oil showing on the sight tube just a yellow froth. What’s my chances of putting oil in it tomorrow and it functioning.

    • @bennycomptech3939
      @bennycomptech3939  5 лет назад +2

      nick mead 50/50 lol
      But in all seriousness as long as your thermal valve is operational and the cooler is clean and the oil isn’t old adding oil should fix it if all you have is a heating issue. HOWEVER a question I would ask myself is WHY is there little to no oil in the unit. Did it leak out? Is the separate filter old allowing oil to pass out the unit. Or was service done to it and not enough oil put in to begin with? So my best advice is dig deeper into your problem rather than just putting a band aid on it so to speak. GOOD LUCK!

    • @nickmeadtanks
      @nickmeadtanks 5 лет назад

      Benny CompTech well benny I got early and more as a clean through I put nearly a gallon of hydronic oil in the compressor and started her up. I seemed to get plenty of air and sprayed some engine decking so I think we may have possibly got away with it ,time will tell.
      Monday I will run it till it’s hot and change the oil with the proper type and check the old oil for debris fingers crossed.

    • @bennycomptech3939
      @bennycomptech3939  5 лет назад +1

      nick mead I wouldn’t recommend putting hydraulic fluid in a Compressor for lubricant lol but if it worked for now and your in a pinch I guess but be aware mixing oils can come with some bad consequences I’ve seen where mixing oils in a Compressor and having the two liquids run at high temperatures caused them to crystallize and destroy the air-end (the part of the Compressor that actually compresses the air)

    • @MR-nl8xr
      @MR-nl8xr 5 лет назад

      @@bennycomptech3939 *hydronic

  • @derrickcsh
    @derrickcsh 6 лет назад

    Hi Benny, do you know how to rectify the problem of XE-90M VSD Controller alarm & warning codes for VSD fault 7

    • @bennycomptech3939
      @bennycomptech3939  6 лет назад +1

      Derrick Chua no sorry man I’m currently not in the industry anymore but I would advise you to have a professional come and look at the VSD as some of these warnings can be very serious problem that could lead to fire hazards and total loss of the VSD and or equipment

  • @thomaseichstaedt4988
    @thomaseichstaedt4988 6 лет назад +1

    Most IR compressors leak

    • @cookingspecial26
      @cookingspecial26 6 лет назад

      Tell me this compressor model number up 5_11ctas_8 all details and all fault solved vedio and my one problem is compressor over heating system is same time Trip.

  • @gl1klvr
    @gl1klvr 6 лет назад

    We have this unit at work and have this exact same issue, plus a potential overheating issue. We have serviced it recently but have not replaced the minimum pressure valve. Also, our recirc valve has always been a little wet with oil. Any idea where we can get the parts list so we can order these parts?

  • @tiendo8378
    @tiendo8378 Год назад

    I'm in garden Grove . Can u come fix my kaeser sk19?

  • @glennscustoms4707
    @glennscustoms4707 5 лет назад

    I have the same compressor and its passing oil through outlet, what could this be?

    • @bennycomptech3939
      @bennycomptech3939  5 лет назад

      Glenns Customs out the discharge where the air leaves the unit or through the air filter?

    • @glennscustoms4707
      @glennscustoms4707 5 лет назад

      @@bennycomptech3939 where the air leaves the unit. Runs for about 10 minutes and shuts down.

    • @bennycomptech3939
      @bennycomptech3939  5 лет назад +1

      Glenns Customs replace your separator filter and the scavenge check valve

    • @bennycomptech3939
      @bennycomptech3939  5 лет назад +1

      Those parts are what’s causing the oil to bypass the unit but while your at it might as well service the unit as well

    • @glennscustoms4707
      @glennscustoms4707 5 лет назад

      @@bennycomptech3939 thank you Benny will do and let you know the results.

  • @parveensharma2661
    @parveensharma2661 7 лет назад

    Dear sir,
    Can u provide the part no of air end seal of compressor model IR UP-11c

    • @bennycomptech3939
      @bennycomptech3939  7 лет назад

      parveen sharma sorry I don’t handle parts I just right up the model number and serial number on the units I work on and our company has a parts department that pulls all our parts for our techs.

  • @Mohd_hamidi90
    @Mohd_hamidi90 7 лет назад

    Hai sir..i have a problem with my air compressor MM45 and MM45 so many time alarm hightemperature..

    • @bennycomptech3939
      @bennycomptech3939  7 лет назад

      Jklm Nopqrs does the machine have oil?

    • @Mohd_hamidi90
      @Mohd_hamidi90 7 лет назад

      Benny CompTech
      Ultra coolant ..can u whatsap me 0198985818
      Im malaysian

    • @bennycomptech3939
      @bennycomptech3939  7 лет назад

      Jklm Nopqrs no lol pay someone to come and fix it for you who knows what they're doing I am on vacation

  • @مصلاحمحمدين
    @مصلاحمحمدين Год назад

    Direction the motor

  • @SuperMalcolm48
    @SuperMalcolm48 5 лет назад

    Pretty typical buried can't get air and wear the motor starter out starting it all the time, to cheap to fix it right alot of company;s out there that run them in the ground.

  • @djveeindahouse
    @djveeindahouse 7 лет назад

    Hey Benny really like your videos. I have question about my ingersoll rand compressor that I would like to ask you. Do you have an email?

    • @bennycomptech3939
      @bennycomptech3939  7 лет назад

      djveeindahouse you can ask here I answer pretty quick all my comments give me a notice on my phone

    • @djveeindahouse
      @djveeindahouse 7 лет назад +1

      Thanks for replying back to me. I have a ingersoll rand 260cfm air compressor btw I'm in Chicago. The compressor starts with no problem but there's no air coming out when I open the valve. Any suggestions would really appreciate it... Thanks

    • @bennycomptech3939
      @bennycomptech3939  7 лет назад +1

      djveeindahouse check your inlet valve make sure it's actually opening when it's running if the inlet valve doesn't open you won't get any air entering the system.

    • @djveeindahouse
      @djveeindahouse 7 лет назад

      Inlet seems to be opening any other suggestions on what it could be

    • @bennycomptech3939
      @bennycomptech3939  7 лет назад +1

      djveeindahouse if the unit runs and the inlet valve is open check your sump pressure gauge basically it's the gauge that indicates there's actually pressure in the system not down the line and if you have pressure in your sump as the unit is running but no air is coming outside of the machine through the discharge then probably your minimum pressure valve is stuck closed

  • @motathugsmcflynava6586
    @motathugsmcflynava6586 6 лет назад

    i am spending around 7 thousand dollars per month, Do you know how decrease this amount of money?

  • @staticxmako
    @staticxmako 3 года назад

    can i paypal you to facetime me and give me like 30 min of you time to help diagnose my issue? on my p185 diesel