A Very Unusual SHORT CIRCUIT! Air Con Compressor PCB Repair V = I Arrghhhh

Поделиться
HTML-код
  • Опубликовано: 11 сен 2024
  • Here's an interesting fault - a blown Air Conditioning controller PCB caused by, ermm, 'environmental conditions'... can we fix it?
    The Electronics Channel (with Carlos and Detlef)
    / @theelectronicschannel
    Gran Canaria Uncovered
    / @grancanariauncovered (with Detlef and Julie. Not electronics related)
    Friends of LER
    Det Builds Stuff - / @detbuildsstuff (Detlef)
    Retro Upgrade - / @retroupgrade (Carlos)
    For All Your PCB needs: free $5 discount coupon
    www.pcbway.com...
    Equipment used in my videos. These are affiliate links, you pay the normal price and I make a small commission.
    TEST METERS
    ANENG AN8009 MULITIMETER
    s.click.aliexp...
    amzn.to/4da4Q7h
    amzn.to/4fsjkkm
    amzn.to/3yuf03q
    amzn.to/4fwQOOD
    www.banggood.c...
    KAIWEETS HT118E MULTIMETER
    s.click.aliexp...
    amzn.to/3yC0ZRe
    amzn.to/3SHIEcy
    www.banggood.c...
    VC480C+ MILLIOHM METER
    s.click.aliexp...
    amzn.to/46Gg1Cm
    amzn.to/3YwUjyn
    MESR-100 ESR METER
    amzn.to/3yxQ0Zd
    amzn.to/3WSr73A
    s.click.aliexp...
    XC6013L CAPACITOR METER
    s.click.aliexp...
    amzn.to/4cf2lzm
    amzn.to/4dw9cp5
    TM-902C TEMPERATURE METER
    s.click.aliexp...
    amzn.to/4fAz44L
    amzn.to/4fBxD69
    LCR-T4 COMPONENT ANALYZER
    s.click.aliexp...
    www.banggood.c...
    amzn.to/3X4rOHv
    amzn.to/3Agcj6h
    FNB58 USB ANALYZER
    s.click.aliexp...
    amzn.to/3MgBFnn
    amzn.to/4dyLU1H
    www.banggood.c...
    PCI POST ANALYZER
    s.click.aliexp...
    amzn.to/4dd8ihw
    amzn.to/3LTpeO7
    TL460S PLUS PCI_E ANALYZER
    s.click.aliexp...
    amzn.to/3WEsdi6
    TOOLTOP ET120MC2 SCOPE
    s.click.aliexp...
    amzn.to/4dCaz5L
    amzn.to/4dxOYLt
    FNIRSI 1014D SCOPE
    s.click.aliexp...
    amzn.to/3AdZqK1
    www.banggood.c...
    NPS3010W 30V 10A PSU
    s.click.aliexp...
    amzn.to/4dzl2yM
    T12 STATION WITH M8 9501 HANDLE
    s.click.aliexp...
    amzn.to/46E73W6
    M8 9501 HANDLE
    s.click.aliexp...
    YIHUA 982 Soldering Station C210/C245
    s.click.aliexp...
    FNIRSI HS-02 PORTABLE SOLDERING C210/C245
    s.click.aliexp...
    amzn.to/3Yv7Ma5
    QUICK 861DW
    s.click.aliexp...
    amzn.to/3WDF4B5
    amzn.to/4ci7rdW
    PROS'KIT SS-331H
    s.click.aliexp...
    INFIRAY P2 PRO IR CAMERA + MACRO LENS
    s.click.aliexp...
    www.banggood.c...
    amzn.to/4coSRle
    amzn.to/4coSV4s
    TOOLTOP ET13S THERMAL CAMERA METER
    s.click.aliexp...
    ET13S MACRO LENS
    s.click.aliexp...
    OPTICAL MICROSCOPE
    s.click.aliexp...
    usa.banggood.c...
    amzn.to/4dzBA9G
    TOMLOV TM4K AF FLEX
    amzn.to/3LY0YKs
    tomlov.com/pro...
    TL866 II+ PROGRAMMER
    s.click.aliexp...
    amzn.to/3SGKL05
    CH341 PROGRAMMER
    s.click.aliexp...
    NC-559-ASM FLUX
    s.click.aliexp...
    DESOLDER BRAID (I use size 8045)
    s.click.aliexp...
    s.click.aliexp...
    HX-T100 SOLDER (0.6MM)
    s.click.aliexp...
    ESD-11 TWEEZERS
    s.click.aliexp...
    Learn Electronics Repair is now on Discord! Come and join the fun, it's free.
    / discord
    If you would like to support this channel
    You can send donations
    www.paypal.com...
    You can subscribe to Patreon
    / learnelectronicsrepair
    Or you can click Join to become a channel member
    Thank you
    Richard

Комментарии • 47

  • @Hellhound604
    @Hellhound604 27 дней назад +6

    Hi Richard, fully agree with your assessment. Hopefully everything works. I would just have coated that damaged area with some coating, like UV-soldermask to prevent condensation from causing another arc-over, seeing that the rest of the PCB is under conformal-coating, I assume this PCB is from the outside unit.

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  27 дней назад +6

      Yeah it is. I still have it at the moment as today (15th Aug) is a public holiday - the assumtion of mary or something like that whatever she assumed - . I do have some soldermask so can give that area a coat before they collect it. Yeah it's from the outdoor unit (compressor?)

    • @rahulmechatronics
      @rahulmechatronics 27 дней назад +1

      @@LearnElectronicsRepair You can use Nail Paint also instead of solder mask

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  26 дней назад +2

      @@rahulmechatronics Dont' tell my missus! she hasnt' got over the uses I found for her nail files and cotton buds yet! 🤐

    • @rahulmechatronics
      @rahulmechatronics 26 дней назад

      @@LearnElectronicsRepair 🤣

  • @VLC8792
    @VLC8792 27 дней назад +3

    I once worked at a small office on some electrical equipment, the mains was connected to 13amp fused spur which was mounted in a galvanised single gang box which was surface mounted. The top cable knock out was missing, therefore dangerous, which is where I found a mouse. The last thing said mouse did was to see what 230v tasted like leaving it’s back end sticking out of the cable knock out.

  • @shagreobe
    @shagreobe 27 дней назад +2

    When I was doing air conditioning/heating repair work, I've ran across many a critter, including mice, numerous types of bugs, snakes, bats, bees/wasps, and probably more I cant remember. Always fun

  • @PurityVendetta
    @PurityVendetta 27 дней назад +7

    I came down to our bathroom one night to find the electric shower running constantly. I checked the switch with bleary eyes, it was off. I pulled the cord to turn off power to the unit and the water stopped.
    On further investigation I pulled the cover to find a large slug shorting the solenoid! On removal of the body the shower was all good.
    I ruled the death as misadventure...

    • @mechanoid5739
      @mechanoid5739 27 дней назад +8

      Ooo! I must check my shower, the water has been running a bit sluggish lately!

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  26 дней назад

      @@mechanoid5739 PMSL 😝

  • @winlose3073
    @winlose3073 27 дней назад +4

    I never knew some AC units use bad quality lizard parts 🤣🤣🤣

  • @ralphj4012
    @ralphj4012 27 дней назад +3

    Ohm's law suggests it could have been a 4.17 Amp and 57.55 Ohm lizard (assuming a 240V RMS incapable lizard). This aircon clearly has a poor reptile IP rating.

  • @chrishartley1210
    @chrishartley1210 27 дней назад +5

    I think the relay probably wasn't powered so the lizard was taking power from the control circuit to the main circuit. That would cause a large inrush current which blew both the fuse and the lizard.

    • @SkippiiKai
      @SkippiiKai 27 дней назад +2

      I'm going back and forth on this. I think the lizard would have enough resistance to act as a decent inrush limiter - enough to prevent the fuse from blowing from the single spike, at least. But it's possible, those caps are huge. But that lizard was charred. And although this is one thing from these vids I will never, ever test myself, I don't think you could cook a lizard to even medium rare on an inrush surge. My own guess is that after switching the circuit on and receiving a quick death, it's tail or foot hit ground or neutral, and that's what gave him the Anakin treatment and blew the fuse.

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  27 дней назад +2

      @@SkippiiKai It is possible part of the lizard touched neutral. I'm the same with you on this one, a both the tracks where it clearly flashed over are live, as is the wider track with some melting/discolouration under the lizard. I accept that not all the lives may have been live at the same time due to the startup relay but I think the current path that blew the fuse, and the lizard, was from the head and underside of the belly on live, to the right hand front and rear legs on neutral

    • @chrishartley1210
      @chrishartley1210 27 дней назад +4

      So the live lizard didn't live after it touched the live, then the short lizard created a short with its tail? That's quite a tale.😮

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  27 дней назад +3

      @@chrishartley1210 a tall tail indeed!

    • @LarixusSnydes
      @LarixusSnydes 27 дней назад +1

      ​​@@LearnElectronicsRepairHomophones can be a lot of fun indeed😁I feel bad for Lizzy. (s)he might have been drawn to this unit attracted by the smell of food from the exhaust, or to unexpectedly have a way to keep itself warm, despite nightfall. Such a harsh punishment😥.

  • @twithheldmwithheld8938
    @twithheldmwithheld8938 26 дней назад

    Awesome work deciphering how the thing works, I really don't know how you keep it straight in your mind, your ability to do that will never cease to amaze me. On a side note, what is with the huge tracks that are populated with small squares? I am assuming there is a reason for this but I am at a loss with guessing.

  • @budgetmerch
    @budgetmerch 27 дней назад +1

    Could be that there is an internal layer beneath the blown area, but hopefully not or we will be seeing this again, for sure. Definitely worth testing at this point, though. It will either work or it wont!

  • @vinnieluther6589
    @vinnieluther6589 27 дней назад +1

    You probably had an arc over from low voltage AC 24v to high voltage. HVAC units have transformers that use 24v AC for signaling. That is why you see 2 different AC inputs on the board.

  • @la4wka
    @la4wka 27 дней назад

    Once had a cockroach short circuit my driveway gate controller board in Spain. Never bothered to calculate its resistance lol. Let’s see part two if this ac will cool again. Interesting videos you make.

  • @Tims_Projects
    @Tims_Projects 27 дней назад +1

    haha, A picture paints a thousand words.

  • @cuanhogan4330
    @cuanhogan4330 25 дней назад

    That area may have been where the arc showed, but the lizard is quite long, so its feet , body or tail could have been across the neutral ?

  • @kriswillems5661
    @kriswillems5661 27 дней назад +1

    This happened a few times to me (a gecko on the airco PCB). I was lucky, it was just the fuse each time.

  • @DumahBrazorf
    @DumahBrazorf 27 дней назад +3

    Poor lizzy :(
    It can happen with automated gates and snails

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  26 дней назад +1

      I would imagine snails would just explode, a bit like a resettable fuse

  • @andytipping70
    @andytipping70 27 дней назад +2

    bit of conformal coating over the arced out area perhaps?

  • @Roman00744
    @Roman00744 26 дней назад

    I'm guessing that 2 black wire connector is going to the fan.

  • @garypoplin4599
    @garypoplin4599 27 дней назад

    1:11 - Looks like what you might call a faulty bridge rectifier (electricity flowed in one direction only - from current to past.)

  • @anfa75
    @anfa75 26 дней назад

    This wasn't debugging, it was delizarding.

  • @jamesdecross1035
    @jamesdecross1035 27 дней назад +2

    Question, do you bother painting a lacquer where the green solder mask is burnt off?

    • @SkippiiKai
      @SkippiiKai 27 дней назад +1

      I would if it were me. Given the condensation that happens in air conditioners, I wouldn't want that kind of liability. Of course, if the laquer actually gave good protection from the circuit, Geico would still have their mascot.

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  27 дней назад +4

      @@SkippiiKai I still have it at the moment as it is a public holiday in Spain today, Thursday, and the shopping centre where my workshop is located is closed of course. I'll put some solder mask on before they collect it tomorrow.

  • @jumadhaheri
    @jumadhaheri 27 дней назад +1

    😅 love the title

  • @bilalxiddiqui3
    @bilalxiddiqui3 27 дней назад

    nice

  • @DadofScience
    @DadofScience 27 дней назад

    Better than a snakey fault, that's for sure.

  • @Dutch_off_grid_homesteading
    @Dutch_off_grid_homesteading 27 дней назад

    Heya, oke it looks oke now again so the owner can try it nice. that pcb looks a little like the main PCB that I have blown up from my all in 1 hybrid inverter that I'm trying to repair whitch I probeble are not able to repair myself. maybe I'm gone ask you Richard to help me some how

  • @jackofalltrades3727
    @jackofalltrades3727 27 дней назад

    obviously the lizards feet was touching ground

  • @davidhollfelder9940
    @davidhollfelder9940 27 дней назад

    The white 2 pin connector is for an on-off switch?

    • @LearnElectronicsRepair
      @LearnElectronicsRepair  27 дней назад +2

      I don't have the unit so I don't know, but seeing as this is the outdoor part of the air con I would be surprised if it had an on/off switch

  • @groovedodger
    @groovedodger 27 дней назад

    I found a dead mouse in a printer once shorted the board never a lizard.

  • @oursongs7554
    @oursongs7554 25 дней назад

    Call 911, the owner statement is required.