  • @t3-tofinototuk.333
    @t3-tofinototuk.333 Год назад +2

    I didn't hear an answer for a E2 error code.

  • @daysgoneby4543
    @daysgoneby4543 5 лет назад +2

    Hiya buddy vans coming along very nicely indeed and definitely agree fella like all things they need maintenance and a good scrub often... All the best fella.

  • @grahamfrear9270
    @grahamfrear9270 3 года назад +3

    Good advice any idea when I purge my diesel heater there is a click that the pump doesn't come on could it be a faulty pump or glow plug thanks any advice would be very helpful Graham

  • @stevesamoffgridsmallholdin5378
    @stevesamoffgridsmallholdin5378 5 лет назад +1

    Some good common sense tips I have an issue at the moment I am going to now go through the things you suggested will let you know if solves the heater problem I have.

  • @stevesamoffgridsmallholdin5378
    @stevesamoffgridsmallholdin5378 5 лет назад

    Looking good so far. I had error code E03. Heater is new but I was primering it a lot at the beginning and must of flooded it. Now after your tips I stripped it down there was a lot of clean diesel inside everywhere so dried it all out, powered up the glow plug that worked great, put back together and now fired up. A lot of smoke for a long time and a chip fat bubbling from the exhaust. Now clear as a bell. So just hoping when I start it up again from cold it will be good. So far happy warm days😀

  • @Cubrider
    @Cubrider Год назад

    I have 07 code on a new heater, ive swapped motherboard and display i have 13.49v and ive cut out and soldered main block connector still getting e07 code. Any ideas? Did work occasionally from new

    • @colebrittner3934
      @colebrittner3934 6 месяцев назад

      Any luck?

    • @Cubrider
      @Cubrider 6 месяцев назад

      @colebrittner3934 no I tried almost everything but I git a refund and bought another thats Neen fine. Only good news was I got to keep the broken one for spares

  • @VanOnTour
    @VanOnTour 5 лет назад +1

    Your van is coming on well mate.

    • @belgrave1984
      @belgrave1984  5 лет назад

      Thanks getting there few more things

  • @melindamarie6139
    @melindamarie6139 2 года назад

    I just got my heater 1 month ago n barely use it. Got a 03 code n i cant take it apart i will mess it up
    Any ideas?

  • @uptowndisco2
    @uptowndisco2 5 лет назад +2

    2 years now my heater has been used in the van , no strip downs , no break downs etc , only difference I have exclusively run mine on paraffin , people say it wears out the pump , but 2 years and still as good as the day installed says otherwise , China pumps are cheap to replace anyways .

    • @fibranijevidra
      @fibranijevidra 4 года назад

      Why you run it on parafin?

    • @peterclancy3653
      @peterclancy3653 3 года назад

      I run mine every now and again on kero, it burns hotter and cleans the screen, glow plug and combustion chamber of carbon build up

  • @GoTerry
    @GoTerry 2 года назад

    It says clear any code and so far he just gives tips ... I'm on 9... wtf remember the clearing codes part.. it's in the description

  • @saibaart
    @saibaart 5 лет назад

    very good big lk

  • @ronbeurs208
    @ronbeurs208 2 года назад

    all that bull and no information on how to clear the codes

  • @ducku21999
    @ducku21999 4 года назад +1

    Great tips. Maybe you can help me. I have two lcd screens. One is for back up. One works fine when plugged in the other one I have has error code E01. Something to do with voltage ? How can this be if the other one works ? Is it faulty ? Thank you.

    • @belgrave1984
      @belgrave1984  4 года назад

      Are they the same controller

    • @ducku21999
      @ducku21999 4 года назад

      Yes. But I just figured it out. Had to go into the 1688 and change to 12v. Thanks for the quick answer

    • @belgrave1984
      @belgrave1984  4 года назад

      No problem

  • @tobyakin8813
    @tobyakin8813 3 года назад

    I have a E 01 code after the first time running the heater and it’s on 12 volts and has 14 volts to heater . The heater has only ran once it’s new could anyone help .

    • @peterclancy3653
      @peterclancy3653 3 года назад +1

      Try checking the voltage at the heater during the start sequence. If your wiring has any great length or a poor connection you could be getting a voltage drop with the glow plug and the fan going. Learnt by experience.

  • @PCFM100
    @PCFM100 3 года назад

    Sorry bong dan, yea replaced the new motherboard and all worked ok. Got to admit the fault was done by me, shouted out the temperature sensor thinking it was a safety switch device....dumb, dumb 🙁🙁

  • @ducku21999
    @ducku21999 4 года назад

    Have you done a video on the different voltage. If not that may be a good episode for you.

    • @belgrave1984
      @belgrave1984  4 года назад

      I did bud but RUclips copyright it because of music in background

    • @ducku21999
      @ducku21999 4 года назад

      Hobbies & Gadgets oh really. I’ve heard RUclips doing this. My friend does a series called plane savers and he’s forever being careful for music background etc.

  • @tcallcrawlrc8595
    @tcallcrawlrc8595 3 года назад

    Well thats misleading never said how to resist codes

  • @stevesamoffgridsmallholdin5378
    @stevesamoffgridsmallholdin5378 5 лет назад

    Hi I fired it up again when it cooled down the fan ran slow for 10 seconds without the pump working then clicked & stopped error eo3. tried a few more times still no good. But I have noticed a regular amount of small bubbles coming out from the pump to the heater distance 18” but no bubbles to the pump all clips good so tomorrow I will take pump & relevant pipes out & re cut & join. Will let you know. Thanks for the interest.

    • @belgrave1984
      @belgrave1984  5 лет назад

      Have u got the pump the right way bud

  • @Pinyoo81
    @Pinyoo81 3 года назад +1

    To avoid carbon buildup, run it on full power for about 5-10 minutes. That will blast out the residue that built up during using it on lower settings.

  • @dripzyy999
    @dripzyy999 5 лет назад

    Yo it's DripzyyYT from xbox

  • @stevesamoffgridsmallholdin5378
    @stevesamoffgridsmallholdin5378 5 лет назад

    Hi john I am still having an issue with my new heater. The first problem was error code eo3 solved it by fitting an eberspacher glow plug but now constantly smoking. But I have noticed constant air bubbles coming out from the pump to the heater but no bubbles to the pump, it is at 45% I have tightened the jubilee clips as tight as poss no difference. I have stripped down heater so many times now full of carbon. Atomiser cleaned put in correct with tool. I am going bald.

    • @belgrave1984
      @belgrave1984  5 лет назад

      Is your exhaust pointing straight down

    • @stevesamoffgridsmallholdin5378
      @stevesamoffgridsmallholdin5378 5 лет назад

      Hobbies & Gadgets hi the heater is under the van the exhaust pipe comes down then a bend slightly down from horizontal to the outer edge of the sill so can drain out if needed I’ve checked totally clear.

  • @AnnsTinyLife
    @AnnsTinyLife 5 лет назад

    I was looking into getting one of these heaters. I don't know though.

    • @belgrave1984
      @belgrave1984  5 лет назад +1

      If I get a upgrade as I like u I will send my one 2 u

    • @AnnsTinyLife
      @AnnsTinyLife 5 лет назад

      OMG really? That would cost a fortune from where you are!

  • @PCFM100
    @PCFM100 4 года назад +3

    Getting an error code 07 can anybody tell me what that one means.

    • @bigirish3383
      @bigirish3383 4 года назад

      I just got it too. Its something do do with the wires. I moved my lcd panel so had to plug it out. But i was still connected to battery. I reconnected then got that error

    • @PCFM100
      @PCFM100 4 года назад

      Thanks John, funny you mentioned that, I did the same, unplugged the plug, then pushed it back in again while battery was still connected. Will disconnect the battery and try again and see what happens.
      There is also a little button type thing, thought it may be a reset, it’s on the bottom of the display, any idea what that is, mine is very loose, seems to be doing nothing.

    • @bigirish3383
      @bigirish3383 4 года назад

      @@PCFM100 not sure how to reset it tho. Let me know if you get it sorted

    • @PCFM100
      @PCFM100 4 года назад +3

      John Mc ginley things have gone from bad to worse. Firstly the screen wouldn’t light up, could see the screen information if I held it at an angle. Error code 07 was shown. Disconnected all the plugs and re connected them again, still nothing. Checked battery, pulling 12 volts which was what the display was showing. Thought there maybe an open sensor or something like that so I disconnected all plugs from the motherboard, all seemed correct ( compared them with another heater that works fine ) still nothing.....ended up re ordering another screen and motherboard, waiting for them to turn up and will try again. Would have liked to changeover the main motor unit but didn’t as the working one was difficult to get out.....time for a drink 🙁

    • @dongoban
      @dongoban 3 года назад

      @@PCFM100 Did you have any joy with the new motherboard? just had this problem on a new install

  • @aspect542
    @aspect542 5 лет назад

    Yo it’s xTydez from Xbox

  • @VanOnTour
    @VanOnTour 5 лет назад +1

    I've got mine ticking over on low using just .4 of an amp.

    • @belgrave1984
      @belgrave1984  5 лет назад

      Nice one u got to love Chinese heater

    • @VanOnTour
      @VanOnTour 5 лет назад

      @@belgrave1984 Yes, well worth the money. I have one in my motorhome and my microcamper I've just converted.

  • @VanOnTour
    @VanOnTour 5 лет назад

    Sounds like yours is running too rich. Change your fuel pump Hz to fan speed ratio to cure it.

    • @belgrave1984
      @belgrave1984  5 лет назад +1

      I had my on lowest setting bud it’s working fine now just can’t work out only use 3 times it was full carbon

  • @gnormanhayes
    @gnormanhayes 4 года назад

    Heater work for 4 days and then burned itself up saying low voltage problem

    • @belgrave1984
      @belgrave1984  4 года назад

      What’s is the voltage saying

    • @blauwzakjecrack
      @blauwzakjecrack 2 года назад

      the heating plug needs cooling of the fan, if the fan does not get sufficient "juice" it wont cool, and thus the heater coil will burn up on itself . That is why the machine is actively cooling down itself after turning it off. Nothing to do about this really except using a proper battery and proper wiring away from hot parts.