Chiller faults - troubleshooting

Поделиться
HTML-код
  • Опубликовано: 12 янв 2025

Комментарии • 75

  • @EngineeringMindset
    @EngineeringMindset  7 лет назад +7

    ⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕
    PayPal: www.paypal.me/TheEngineerinMindset

    • @DubaiVlogggg
      @DubaiVlogggg 7 лет назад +1

      The Engineering Mindset which country are you from?

    • @cata7251
      @cata7251 4 года назад +1

      Coffee is served from my side! Keep going. Thnks!

    • @timmyfoltz2022
      @timmyfoltz2022 3 года назад

      @@cata7251 p

    • @timmyfoltz2022
      @timmyfoltz2022 3 года назад

      pp

  • @EngineeringMindset
    @EngineeringMindset  5 лет назад

    Learn *CHILLER SURGE* problems here: ruclips.net/video/DQK_-vxObiw/видео.html

  • @STEINYY
    @STEINYY 4 года назад +7

    Hey Paul, how are ya? I was wondering if you could make another video about troubleshooting? Common faults with AC units, chillers, heat pumps? I would like a video like this, it was helpful for me. / Lineus

  • @harvindersingharora3845
    @harvindersingharora3845 4 года назад +1

    You are my teacher of the day! Thank you.

  • @eulaliorodriguez5325
    @eulaliorodriguez5325 Год назад

    Thank you for sharing this HVAC VIDEO.

  • @mukeshkumar-sl4wu
    @mukeshkumar-sl4wu 3 года назад

    Good morning Sir
    Very nice explanation..thanks

  • @Afzalkhan-tk9mv
    @Afzalkhan-tk9mv 7 лет назад +3

    sir make a vedio on how calculate usgpm of water ...and selection of pipes in chilled water cycle and condenser water cycle

  • @manikantabalusa441
    @manikantabalusa441 5 лет назад +1

    Pls upload a video of preventive maintenance activities for water cooled and air cooled chillers

    • @delrey-p
      @delrey-p Год назад

      It would probably be a 3 minute video mate. Very simple to do. The title PPM says it all.

  • @DubaiVlogggg
    @DubaiVlogggg 7 лет назад +2

    Keep up the good work bro ! Excellent .

    • @ravikushalappakushalappa5239
      @ravikushalappakushalappa5239 7 лет назад

      Good work keep it up

    • @jollyscaria1922
      @jollyscaria1922 10 месяцев назад

      Isues lot off dis charge sushion gas low fult trobels alrom dis plsy and tdmpseting very imprsnted pump watr pslow lording cooling effeating condeder celin pm must condesfsn snd aif folw swich wofkinv lot ful dolvrig mattrs

  • @zoransvracic3219
    @zoransvracic3219 6 лет назад +1

    is there any step by step guide on how to preform leak check of chillers?

  • @chooonz1396
    @chooonz1396 6 месяцев назад

    We have Flow sensor Issue. Chiller 2 shuts down and shows "waiting for evaporator water flow". We already tried swapping the flow sensor and tried it on Chiller 1, both flow sensors from Chiller 1 and 2 functioned well in Chiller 1.
    Is it a communications issue? What should we do to troubleshoot? Should we just contact the supplier?

  • @muhammadazhariqbal5304
    @muhammadazhariqbal5304 4 года назад

    can i connect evaporator inlet from cooling tower instead of water tank will it effect ? thanks in advance

  • @amiramjad2022-v1e
    @amiramjad2022-v1e 4 года назад

    Hi thanks for your amazing videos you can talk and expalne how to setting CLIVIT CHILLER PLZ

  • @porfiriofranco5070
    @porfiriofranco5070 3 года назад

    Hi, why the main cause for frezzing in the evaporator??

  • @ejazahmed1131
    @ejazahmed1131 2 года назад

    Hi I have chiller 30ax carrier
    I have problem compressor started but condenser fan not getting started
    Pls advise me

  • @brandonmccary27
    @brandonmccary27 2 года назад

    What does ‘ latched - fault mean on screw air cooled chiller

  • @akashgayakwad3929
    @akashgayakwad3929 2 года назад

    ln my lab chiller is showing 50degree centigrade temperature of collent since actual measured temperature of collent is 20 degree.
    please suggest me a proper solution of this issue??

  • @Your_searching_ends_here
    @Your_searching_ends_here 6 лет назад +1

    Explain about chiller anticycle

  • @sonudandiwal777
    @sonudandiwal777 Год назад

    When chiller running igv not properly open but hot bypass line open around 70% open so chiller not working properly

  • @mohdal-ameed6831
    @mohdal-ameed6831 3 года назад

    Thank you.

  • @christopherwheaton282
    @christopherwheaton282 Год назад

    Hi can I still drive when the chiller tripped out only have chiller thanks

  • @charlitomarcosjr1057
    @charlitomarcosjr1057 5 лет назад

    How to fix low discharge superheat in york chiller?

  • @alinusrath5431
    @alinusrath5431 2 года назад

    Patra Chiller commpresor proof faulty how to mack pls tell me vedio

  • @Enayatmauna
    @Enayatmauna 6 лет назад +1

    what types of problems create in chiller plant

    • @md.perwez2179
      @md.perwez2179 3 года назад

      Please review this video and read the screen

  • @danellim2553
    @danellim2553 5 лет назад

    my client's chiller circuit board burn cause by lizard... another one is fan and compressor not running. the control shows E 26 was error.. ps: im new to it

  • @ahmedazhri9126
    @ahmedazhri9126 5 лет назад

    Thanks for your lecture
    I have some questions
    My chiller trip on low pressure in evoprter

    • @Apkaa
      @Apkaa 5 лет назад

      Elaborate bhai

    • @azinuddinasri3394
      @azinuddinasri3394 3 года назад

      You need to get the diffential pressure between in and out as per chiller requirement, need to get peformamce data from supplier and check the differential pressure, then u need to adjust your butterfly valve accordingly to get the right pressure

  • @shashishashidar9649
    @shashishashidar9649 2 года назад

    Trane CDHG water cooled chiller
    Refrigerant- R123
    Problem- chiller not going load more than 80% and not achieve set temp,we changed leaving water sensor,saturation temp sensor,refrigerant charged,manually igv open,water flow is normal but still problem not solved,please suggest me

  • @nasimahmadkhan2954
    @nasimahmadkhan2954 5 лет назад

    Please you help 20 ton LG package unit 5 ton compressor section line hitting what problu?

  • @vishalsalve2261
    @vishalsalve2261 6 лет назад

    sir please tell me about
    antifridge activatedalarm

  • @marcusjones8683
    @marcusjones8683 4 года назад

    How do you bleed a chiller unit

  • @miguelloza4454
    @miguelloza4454 6 лет назад

    Hi I’m having trouble with a bitzer compressor i replaced oil pressure switch and now compressor won’t come out of pump down or go into refrigeration mode any suggestion on wat to check

    • @gabrielvillanuevaiii3926
      @gabrielvillanuevaiii3926 6 лет назад

      Miguel Loza check for a possible defective low pressure switch or one that is improperly adjusted

    • @ndzondelelojekeqa5778
      @ndzondelelojekeqa5778 6 лет назад

      Guys watter chiller is not running HI Temp Tripped light is on help me what I need to do

    • @gabrielvillanuevaiii3926
      @gabrielvillanuevaiii3926 6 лет назад

      Ndzondelelo Jekeqa If it is a high refrigerant temperature/pressure alarm on a water-cooled chiller, check the condenser pump strainer. If it is on an air-cooled chiller, check the condenser fans if they are operating correctly

    • @EngineeringMindset
      @EngineeringMindset  2 года назад

      Seen our new pressure switch video? Link: ruclips.net/video/YG81w0HFXNc/видео.html

  • @engeng3012
    @engeng3012 5 лет назад

    Hello guys...i want your help in this i am still newbie with hvac system and in the place where i work there is swas chiller. From time to time cause high pressure alarm..what do you advice me to inspect which part..i inspected condenser filter and fan motor.. plz i need your help with that..thx

    • @EngineeringMindset
      @EngineeringMindset  5 лет назад +2

      Condenser water temperature is most likely the cause. Check the chiller error code and temperatures

    • @engeng3012
      @engeng3012 5 лет назад

      @@EngineeringMindset I would like to thank you for the quick reply .The chillers are using at the power plant are air chiller not water chiller. Today we had low pressure alram so churged with refrigerant and make sure that the valve expansion and pipes are intact. 3 chillers low pressure alram and one chiller is high pressure.the set point on 77 f. What do u expect????? Thanks Again

  • @Bhajankerasik
    @Bhajankerasik 4 года назад

    Low amps drawn by compressor??

  • @vinznes7792
    @vinznes7792 5 лет назад

    How to do if got alarm c1cmp1 off motor temp high

  • @ashaoluadeleke9906
    @ashaoluadeleke9906 5 лет назад

    Please how can I clears the fault using the keypad for York chiller

    • @jthigpen2967
      @jthigpen2967 5 лет назад +1

      log in service menu then clear the fault. if you don't have the code stay out of it and call your local service agency

  • @anishkhananish7994
    @anishkhananish7994 Год назад

    The aircon chiller error -93 comming what problems brother

  • @asadmehmood8065
    @asadmehmood8065 6 лет назад +2

    Sir Kindly Send me Softcopy of Chill fault and trouble shooting

  • @masterchef6694
    @masterchef6694 7 лет назад +3

    Thanks for sharing knowledge. Could you do a video on ahri standard for rating chiller performance data.

    • @anamsiddique13
      @anamsiddique13 7 лет назад

      I have problem rtaa 430 chiller latche fault any body help to solve this

  • @franklinknight1460
    @franklinknight1460 5 лет назад

    How can I troubleshoot if one cooling tower, one condenser water pump and one chiller water pump are not working. help me please?

    • @EngineeringMindset
      @EngineeringMindset  5 лет назад

      Check the chiller or bms screen for error codes. This time for year its probably low temperature and the chiller has tripped to protect itself

  • @shaikhrahman1848
    @shaikhrahman1848 3 года назад

    Please discharge temperature high alarm

  • @hamidjamal9740
    @hamidjamal9740 2 года назад

    Troubleshooting pdf link please

  • @ahmedazhri9126
    @ahmedazhri9126 5 лет назад

    What is the solution

  • @mdafaquealam6070
    @mdafaquealam6070 4 года назад

    Motor temperature highin aircooled screw, what is problem

    • @christopherwheaton282
      @christopherwheaton282 Год назад

      Temp on dash ok can't turn chiller on hot under bonnet. Is it OK to drive without chiller

  • @IftikharAhmed-qi2sw
    @IftikharAhmed-qi2sw 5 лет назад

    How to check heat exchanger seance chiller complete b m s control chiller fully shit Dow

  • @SoldadoJESUSCRISTO
    @SoldadoJESUSCRISTO 2 года назад

    Different color on merchandise please!?

  • @EJD339
    @EJD339 4 года назад

    Any building automation techs watching this video?

  • @jollyscaria1922
    @jollyscaria1922 10 месяцев назад

    Prmary pum secndry pump wate flowing valve oponed full checking prssur dros up line allchecking very imprsnted

  • @Learntogether2051
    @Learntogether2051 6 лет назад +1

    How to start a mcquay chiller

    • @EngineeringMindset
      @EngineeringMindset  6 лет назад +1

      Find the description of operation manual for the building and the manual from the manufacturer.

  • @Your_searching_ends_here
    @Your_searching_ends_here 6 лет назад +2

    If surge happens in chiller... Chiller won't shutdown ah

  • @Suneelkumar-zu7om
    @Suneelkumar-zu7om 3 года назад

    Good Night

  • @markthomas3858
    @markthomas3858 3 года назад

    56 non contributors…

  • @davidecasarin4953
    @davidecasarin4953 2 года назад

    LOUDER PLEASE

  • @mdziarulmolla6303
    @mdziarulmolla6303 6 лет назад

    Ziya