O' General inverter compressor stop after few seconds
HTML-код
- Опубликовано: 18 мар 2021
- Hi Friends welcome to ELECTRIC LOCHA
My Gmail ID : - raj2324300@gmail.com
mobile and whatsapp No -: 9213717087
All about of this video
problem in the inverter AC. The compressor of the inverter AC stops after few secands. Compressor of the inverter AC stops after running for 10- 15 seconds. This problem often comes in the inverter AC. So today we have PCB of O General Inverter AC, then this problem is coming in the PCB of this O General Inverter AC. Ccompressor runs and stops for a while, then friends. first of all, today we will test it with UVW tester. If all of the UVW phase is coming properly or not. if all of phase coming from PCB, then there may be a problem in the compressor. but if the UVW is not coming properly from the PCB, there is a phase missing or it is incomplete. then its Meaning there is a problem in the PCB. friends, we have only the PCB, we will check this PCB from our UVW tester and find out if the problem is the IPM is bad or something else, let's see in the video
दोस्तों आज हम आपको इन्वर्टर AC के बारे में बताएंगे। इन्वर्टर एसी में दिक्कत है। इन्वर्टर एसी का कंप्रेसर कुछ सेकंड के बाद बंद हो जाता है। इन्वर्टर एसी का कंप्रेसर 10- 15 सेकंड तक चलने के बाद बंद हो जाता है। यह समस्या अक्सर इन्वर्टर एसी में आती है। तो आज हमारे पास ओ जनरल इन्वर्टर एसी का पीसीबी है, तो इस ओ जनरल इन्वर्टर एसी के पीसीबी में यह समस्या आ रही है। कॉम्प्रेशर थोड़ी देर चलता है और रुक जाता है, फिर दोस्तों। सबसे पहले, आज हम इसे यूवीडब्ल्यू परीक्षक के साथ परीक्षण करेंगे। यदि सभी UVW चरण ठीक से आ रहे हैं या नहीं। यदि सभी चरण पीसीबी से आते हैं, तो कंप्रेसर में कोई समस्या हो सकती है। लेकिन अगर UVW पीसीबी से ठीक से नहीं आ रहा है, तो एक चरण गायब है या यह अधूरा है। तब इसका अर्थ है कि पीसीबी में कोई समस्या है। दोस्तों, हमारे पास केवल PCB है, हम अपने UVW टेस्टर से इस PCB को चेक करेंगे और पता करेंगे कि क्या समस्या IPM खराब है या कुछ और है, आइए वीडियो में देखें
subscribe this channel
so friends thank you
Face book : profile.php?...
Instagram : raj232430?...
Thanks Наука
Grate sir ji. Jai bhavani
Sir your vedio performance very useful for repairing field. Thanks for sharing all.
Very informative video
Thank you sir kee it up.
Very good I alway watch your videos ✌️💯
Useful video
🙏Thanku sir
Great info thanks 👍
My favorite channel sir ap great hai
#smarttechskill
Very good information thinks Bhai sahab
Excellent work
Good work 👍
Excellent.
Sir ji Very Nice 👍
Sir u r grate
Very nice sir
Good tiching welcome 👍👌👌👌👌👌👌👍❤️🔥🎉👍👍👍👍👍👍
Good teaching
very nice
Nice bro
Good i have this ac i am in Bangalore
Main ne bauhat kuch seekha sir Ap se
Good
very nice,,,,, jai hind,,,, jai Bharat
Jai hind
Good video jayhind
Thanks big bro Jai Hind
👍
👍👍👍👍👋
Sir can you tell me urgently why that 27 K ohms resistor kept in place of thermistor why only 27k ohms???
Please tell me urgently....
Sir invetar outdoor PCB repairing karvana hai sir
Jai hind jai bhart
Jai Hind big bro
Sir compressor 15 chalkar band hoga ki kuch samay bad for chalu hoga . Hum samaj nahi paye please🙏 bataye.
Hi sir i have same problem with ariston ac inverter. Pcb is hisense.. can you help me? Thank you sir
Can we check outdoor inverter without indoor unit
Sir jee uvw tester ka price kya he
Sir pcb main mini power supply kaise lagate hai
Really nice video
hlo sir namaskar
i am your big fan aapk sab video dekhachuka hu sir mera question ya he ke hisense ac 4 ton floor stand ac may error 11 ((Sequence error))
Three phase power supply wiring line sequence error aaya hey how to find out please give me some ideas
big bro, apne phase change ker ke dekha ?
Sir repairing sikhne ka kitna charges h
Sir ji aux inverter F1 error pe video banaye
Vfd se inverter compressor chla sakte hain?? Plz answer me.. Or make vidio about it..
Ok big bro I will make video
Daikin inverter A.c me ye fholt hai to kya kar na hoga pls aap bata na
Agar mera pass sirf multi miter hai to kaisa pata kra kon sa ne negative or positive missing hai..yea sensor krap hai
Sir ye tester out of country b aap delivered kr shtai hai?
big bro out of country shipping bohot jayda hota hai
Bhai aap kahan sa ho
Opration 9 Blink Timer 4 Blink Pls Kya Problem Hai Bataye
I m from Pakistan plz send me the daigram of the testing equipment of invertor ac compressor .and also send me the uvw tester daigram
Thankyou
सर इन्वेटर ac में एक्सपेंसिव वाल्व के वोल्टेज कैसे चेक करे
Sir mein 1 month pehelay ek 2022 model whirlpool ka 1.5 ton inverter 5star inverter ac kharida huin. Ac acha cooling karta indoor blower regular acha se bhi chalta hai.
Per outdoor unit ka fan kuch second ya 1 mint keliye stop hojata hai fir auto start hota hai.
Per mera ac achasa cooling karta reheta hai..
Sir kiya mera ac kharab hai?
Pls replay me first
agar cooling thik karta hai to kharab nahi hai
Sar Inverter AC repairing ke liye alag se Maltimeter chahie hota hai kya ....?
Nahi big bro
mujhe ek p.c.b repair shop keeper n bola tha isliye puchha tha main aap se..
UVW tester kase milega aur price kitna hoga , aur ye tester inverter fridge me kam krega ki nhi
ye tester sabhi me kaam karega . agar aap lena chahte hai to call us 9213371707
Ek main ne bhi Lena hy
I am from jalal pur pir wale district Multan Pakistan
Hello sir
Hi big bro
Haier inverter ac ka compressor start ho kr band ho jata hai, IPM bhi ok hai.
Please help kren.
Where we can repair out door pcb
uvw ka kya price hai
Bhaiya very very very nice
Sar uvw taster prise
Bhai kiya hum vfd se compressor chaldakte hain
big bro hum next month compressor drive launch kerne wale hai . isse aap sabhi ac and fridge ke compressor run ker paynge .
Hame UVW meter lena hai sir ji.
Sur ji U v w testar मेरा चाहेगा एक
Sir 5v short nahi mil raha hai bahot pareshaan hu Kya karu
I have a 1200btu Panasonic inverter at home, whenever the compressor start and reach a certain rpm it stop
12000btu
Main Bangladesh se hun mujhe UVW tester chahiye keise milegi pls bataye
Hume call karo 9213717087
@@electriclocha uvw tester price?
Rs, 2200 only big bro
Sir UVW tester kitne ka milega aapke pass se
call us 923717087
U v w tester kaha milega sir
Humare paas milega
Ksha se ho sri
Delhi se big bro
UVW tester price
2200 Big bro
Sir ji phone Nahi accept Ker rahe ho Mene inverter compressor check Keene wala Lena tha
Sir g UVW tester please send me confirm price by Pakistani rupees
Ek main ne Lena hy
Address . 786 stabilizer Jalal pur pir wale district Multan Pakistan
O genral inverter ac ki PCB repair karani he
Ok
contact nambar
9667663078 you can call me
UVWٹیستر مجھے چاہئے
Mo
Sir aapkaa nobarchahiye
BM AMD mo= moklo
Hello bro mujhe coach device chahiye main aapka contact number mein call kar raha hun lekin call nahi ja raha hai aapka WhatsApp number Deja main aapko contract karta hun
Aapshe dodi bhat karni hye
Sir app ka mobile number mil skta he
9213717087
UVW TESTER KI PRICE KYA H
2200 only big bro
@@electriclocha apna wats app nmber share krain......
@@electriclocha sir apna numbr do
Description me no hai
Please number de do apna
9213717087
Sir dc inverter compressor checking device bhi bana do plzz .
Ok big bro , As you wish
@@electriclocha super sir humku bhi p c b repair siknahai sir rasta batadijiy sir
aap se ac ki plate repair karwani h plz adress bataiye
Google per electric locha search karo address mil jayga