Testing Defrost On A Lennox 2019 ML14XP1

Поделиться
HTML-код
  • Опубликовано: 2 янв 2025

Комментарии • 21

  • @bill944
    @bill944 3 года назад +6

    Not necessary to disconnect the fan wire or move the jumper. Just use the tip of needle nose to jump out the test pins for about 2 seconds. It'll speed up the defrost timer.

  • @roqueherrera8471
    @roqueherrera8471 Год назад

    Need an answer hopefully by tomorrow isn’t…..😅😂

  • @sknight0391
    @sknight0391 3 года назад +7

    If you would have pulled the jumper shunt back off immediately after the unit initiated defrost it would have stayed in defrost until the sensor warmed up and opened back up. Leaving the jumper shunt on will just speed the test up and kick it right back out. Those boards come factory set at a 90 minute intervals. For you guys that live in colder climates you need to make sure you move the jumper shut down to 60 minutes. An hour and a half of run time, in between defrost cycles, is way too long in colder climates. And if you're up north or in a higher elevation (above the frost line) I would go ahead and set it to defrost every 30 minutes.
    😎👍😎👍😎👍

    • @Techhead777
      @Techhead777 3 года назад +3

      Taken from the Installation instructions as I have the same board - Test Mode Sequence: Using the defrost termination pin, short the TEST pins for a period of two seconds: Clear timed lockout / or pressure switch lockout function.
      Enter defrost mode. After entering force defrost, if the jumper is removed before 5 seconds has elapsed, the unit will remain in forced defrost mode until defrost thermostat opens or terminated on maximum defrost time (14 minutes). If the jumper is not removed, once 5 seconds has elapsed (7 seconds total), the unit will terminate defrost and return to heat mode. The TEST mode will then be locked-out and no further TEST mode operation will be executed until the jumper on the TEST pins is removed and re-applied to the applicable termination pins.
      In regards to the missing jumper - If the timing selector jumper is missing, the defrost control defaults to a 90-minute defrost interval.

    • @ov2487
      @ov2487 Год назад

      thanks 👍

  • @jbeagles30
    @jbeagles30 6 месяцев назад

    I’m working on a Lennox air to air heat pump. Only runs when I jump out test mode or the test defrost. Says circuit board failure. I ordered a new board. But if it runs when I jump out defrost, isn’t that board good??? I’m so sick of these heat pumps lol help

  • @justinberrett7479
    @justinberrett7479 3 года назад

    Thanks I enjoy these shorter( under 10 min) videos

  • @roqueherrera8471
    @roqueherrera8471 Год назад

    So I just mess with on like this… recent install heat pump cool mode runs fine but heat mode with in 15 seconds my pressures sky rocket to 575 psi on high and low. Also gives me a code of ambient temperature sensor problem. What would cause that BO$$ man. I diagnosed it as a TXV problem what u think

  • @jkbrown5496
    @jkbrown5496 3 года назад

    I believe those jumpers are standard 2.54mm Circuit Board Jumper Cap Shunts used on pretty much all circuit boards. Cheap to have spares in your bag if so.

  • @sknight0391
    @sknight0391 3 года назад

    Holy sh!t, your working on a Lennox.

  • @Techhead777
    @Techhead777 3 года назад

    Sounded like the unit was already in defrost because the fan ran after it cycled and you reconnected the fan terminal on the board. It might had kicked out on its own without the jumper and was just a coincidence. Those metal panels on the Lennox's seem to be awfully noisy and vibrate and rattle. I certainly wouldn't recommend one outside a bedroom window. They start with quiet a jolt, especially the heat pumps. I had to tweak the panels so they wouldn't vibrate and rub on the coils. Took quite a bit of time to get it just right.

  • @vaeagle1
    @vaeagle1 3 года назад

    you can see where the gutter has been overflowing down the perimeter of the house right on the edge of the unit , people never do preventative maintenance.

  • @wallywal5475
    @wallywal5475 2 года назад

    Nice, have a Concord. Gotta the board from Lennox

  • @fvfgx
    @fvfgx 3 года назад

    One weird thing about Lenox heat pumps is that there's no accumulator

  • @bobakleh1397
    @bobakleh1397 3 года назад

    Nicccceeeeee. Thanks

  • @alexprowse5120
    @alexprowse5120 2 года назад

    Must be nice to wear jeans and a leather jacket to work there Fonz

  • @annaleetru
    @annaleetru 3 года назад

    Other way bypass connect together Defrost Thermostat It's will Defrost after 10 second.

    • @HVACGUY
      @HVACGUY  3 года назад +2

      Yes, but this way we are also checking the defrost thermostat.

  • @stephwaylonwells3218
    @stephwaylonwells3218 3 года назад

    👍

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 3 года назад

    🍺😐👍🏻