Nice installation, 😀 For how many hours will it aply power to 2xac 2x frich and 4fans 5 bulb? And what ampere battery will need how many? Thank you for great video 👍
bhai jan aik 12v 100amp DC relay laga lu ? mene 5 rooms me aik aik fan or aik dc light use karni hai dc ki is k elava DC MOTOR ko b connection dena hai KIA me 100amp ki aik relay se out put me alag alag wires . rooms k lia le ja sakta hon ya zeyada RELAYS lagni hain ? 100amp SIMTEK + 2 panels 585watts 4 ac dc 12v fan load....6 bulb 12v or kabi kabi 12v DC water pump
اسلام وعلیکم سر میں اپنا گھر بنا رہا ہوں اور میں فیوچر میں سولر بھی لگانا چاہتا ہوں تو کیا مجھے اپنے گھر میں سولر کے لے الگ سے نیوٹرل لگانا چاہتے یا گھر والا نیوٹرل ہی کافی ہو گا
Wa Alikum Salam Agr to apka plan 8kw ka hai to phr ap byshak natural aik he rhny dy bs apny heavy load k liya alag sy cable aur breaker dp m rakhwa lay
Bhai installation ki video may Breakers AC and DC aur tamam protection devices , change overs waghera k connection zarur sikha diya karen asal kaaam to wuhi hy
@@ToorElectric mere ko ek problem aari hai jab battery grid se charge hoti raat me to 100% ke baad band ho jati jo ki shi hai ..lekin jab din me solar se charge hoti to 100% k baad bhi 500w se charge hoti rehti poora din mtlb overcharge hoti hai solar se …290ah ki 8 battries hai 12kw ka solar plant
Bhai mera inverter on hota hai 1000 watt arhe hote hen phr bhe load on nh hota phr thori dyr bd khud ho jata hai help karen q nh hota jese pv watt ane lage load chalna chaiye
Bhai kesy han ap. Yr aik bat zror bta dyn. ye jitny b inverters han jo without battery chal jaty han hybrid waly. Kia wo bna battery Wapda and solar sharing ke sath bilkul thek chlty han ya bar bar battery na hony ki wjha sy error dyty han agr load daly to. zror btaiye ga
@@ToorElectricNo brother in par fan light bhe full night on nahe hogi... Apko minimum 185ah tubbler use karna chaheay thi... Or hamesha wire 30 mm say kam na lo...
Bhai acha kam kiya hy lakin aap aik cheez ka khayal nahi kar rahay .aik to sab panel k beech may minimum 3 say 4 inch ka fasla dain.takay jb full air pressure ho tb bhi hawa say panel damage na ho .aap nay jo gap diya hy wo kafi nahi hy .secondly jo plarform banaya hy us k jo bhi pipe floor say lag rahay hain un par cement ka box banwain us ko full strength dy nay k liya.q k jb hawa chalti hy or andhi ati hy to bogit zyada pressure parta hy .baqi aap nay battery smart load par 90 percent per set ji hy .meray khayal may ya bohut zyada hy .jb smart load per 90 percent per batter cut off hogi or us waqt agar wapda ki supply na hui to system shutdown ho jay gaa.secondly bohut important cheez Hy earthing apnay tamam customers to earthing ka lazmi advice karain Jo hum ignore kar dyty Hain.
Bhai maire pas 6kw ka hybrid system laga hoa hai but problem ye hai k din ki bharpoor garmi mein bhi wapda se sharing karta hai agar load 3kw chal raha ho to 2kw solar se chal raha hota hai jab k 1kw wapda se sharing ho rahi hoti hai plz solution batain
Bhai jo angle naklanay k laye app ha woh kon se ha
Iphone m default app hai
Outclass installation
Jazak Allah
Nice installation, 😀
For how many hours will it aply power to 2xac 2x frich and 4fans 5 bulb?
And what ampere battery will need how many?
Thank you for great video 👍
It start working 7am to 5pm in summer
Good
Thanks
Great work. It would be nice if you tell the total cost of the project.
I'll do in next videos
Bhai jan 1 more question plz knox krypton 8000 6kv or tesla hle 6kv or solarmax orion 6kv me konsa best hai
Brother 2no he nhi use kiya abhi tak
bro 8kw nitrox k sar strings paralel me ya series me lagani chaye?
Series
bhai jan aik 12v 100amp DC relay laga lu ? mene 5 rooms me aik aik fan or aik dc light use karni hai dc ki is k elava DC MOTOR ko b connection dena hai
KIA me 100amp ki aik relay se out put me alag alag wires . rooms k lia le ja sakta hon ya zeyada RELAYS lagni hain ?
100amp SIMTEK + 2 panels 585watts
4 ac dc 12v fan load....6 bulb 12v or kabi kabi 12v DC water pump
G aik he relay sy hojyga apka kam ap lga skty hain
umair bhai is poora system ke lgane ka kitna mazdoori liya hai .
kindly reply me
5 per watt
اسلام وعلیکم سر میں اپنا گھر بنا رہا ہوں اور میں فیوچر میں سولر بھی لگانا چاہتا ہوں تو کیا مجھے اپنے گھر میں سولر کے لے الگ سے نیوٹرل لگانا چاہتے یا گھر والا نیوٹرل ہی کافی ہو گا
Wa Alikum Salam Agr to apka plan 8kw ka hai to phr ap byshak natural aik he rhny dy bs apny heavy load k liya alag sy cable aur breaker dp m rakhwa lay
Bhai 9panels ki 2strings support krygi isko???
G
Bhai installation ki video may Breakers AC and DC aur tamam protection devices , change overs waghera k connection zarur sikha diya karen asal kaaam to wuhi hy
Ok brother
Bhai ye lewal wali konsi aap haii
Apple ki default app hai bro
Good work brother
❤
But there is one mistake
Breaker mn u type lugs nahy lagta pipe lugs laga
By the way i love your work ❤️
Ok sir
U type thimble change over k liya thy
@@ToorElectric keep it up
Nice bro mazeed video be dalna ❤
Ok sir
battery jo mai wo A pe set krni hai ya % pe …for lead acid
Apka question clear nhi ha kindly comment again with explained question
@@ToorElectric mere ko ek problem aari hai jab battery grid se charge hoti raat me to 100% ke baad band ho jati jo ki shi hai ..lekin jab din me solar se charge hoti to 100% k baad bhi 500w se charge hoti rehti poora din mtlb overcharge hoti hai solar se …290ah ki 8 battries hai 12kw ka solar plant
Can UPS be used for 6 kW solar system
No
Bhai mera inverter on hota hai 1000 watt arhe hote hen phr bhe load on nh hota phr thori dyr bd khud ho jata hai help karen q nh hota jese pv watt ane lage load chalna chaiye
Contact on WhatsApp
Dost 8kw 16 panels k sath 32amp k 2 DC breaker laga sakte hain ya 63amp k 2 lagane chaye??
32 k b use kr skty hain
Bhai mery pas ups h homeage ka ma 2 fan ak led 2 light lagna chati hu kitny tk ta setup bany ka bhai kuch sa idea dedy please 😊
Almost 90k to 100k m ap usky sath mppt aur 2 solar pannels lg skty hain
Bhai kesy han ap. Yr aik bat zror bta dyn. ye jitny b inverters han jo without battery chal jaty han hybrid waly. Kia wo bna battery Wapda and solar sharing ke sath bilkul thek chlty han ya bar bar battery na hony ki wjha sy error dyty han agr load daly to. zror btaiye ga
Battery ho to zaida best hai q k wapda bar bar gayaib hojti ha
❤ good working
Thanks
V good information
So nice of you
bro 8kw nitrox k sat maxi kitni panels 580 w lagani chaye
16
bhai me ne 18 panels 580 w purchase kye hn. panels ko series me ya parallel me lagani hn? plz jaldi reply de
Ac and Dc Earthing? Lightning Erestor ?
Wo b hogya and net metering b
@@ToorElectric bhai us per bhi detail bnao erthing per .next video me lazmi mention kren
@@ToorElectric punjab k kisi bhi city me ap service deto ho ya only lahore ???
Ap ki srves kon c cti my hy
Narowal-Lahore k qareebi area
Yar meri Minimum battery limit pe phonch kr battery percentage direct 0% hojati hai. Bata skte ho kia masla ho skta hai ?
Apki bat smjha nhi kindly whatsapp py rabta kry
Bhai nytrox 6kv white k sath 585 watt k 9 panels series main lga dain TU voltage over ka koi masla tu ni bnta or koi issue tu ni
2 string krly
@@ToorElectric Bhai panels 9 hi lgane Hain TU do string kese bnayen
@@ToorElectric wese series main 9 lgane ka koi issue TU mi
@@ToorElectric ni
Yai Inverter hybrid hai ya off grid?
Hybrid
Bro 4 batteries lagae hen apney, yai batteries puri raat chal sakti hen?
Fans + lights k liya chl skti hain
@@ToorElectricNo brother in par fan light bhe full night on nahe hogi... Apko minimum 185ah tubbler use karna chaheay thi... Or hamesha wire 30 mm say kam na lo...
Welldone brother ❤️ brother installation charges kitni hain ap ke?
Contact on WhatsApp 03038086698
Good bhai is ma kitna kharcha laga list nhi dikhai ap ny
Total cost niklna bhool gy video m
Chalo koi masla nhi sir Allah ap ko kamiyaabi dy hamesha
Bhai acha kam kiya hy lakin aap aik cheez ka khayal nahi kar rahay .aik to sab panel k beech may minimum 3 say 4 inch ka fasla dain.takay jb full air pressure ho tb bhi hawa say panel damage na ho .aap nay jo gap diya hy wo kafi nahi hy .secondly jo plarform banaya hy us k jo bhi pipe floor say lag rahay hain un par cement ka box banwain us ko full strength dy nay k liya.q k jb hawa chalti hy or andhi ati hy to bogit zyada pressure parta hy .baqi aap nay battery smart load par 90 percent per set ji hy .meray khayal may ya bohut zyada hy .jb smart load per 90 percent per batter cut off hogi or us waqt agar wapda ki supply na hui to system shutdown ho jay gaa.secondly bohut important cheez Hy earthing apnay tamam customers to earthing ka lazmi advice karain Jo hum ignore kar dyty Hain.
Thanks for your information
Sir masjid mai 10 panel lagway hai ,inverter Mai os ki setting kisay Karni hai
Konsa inverter ha apny installer ko boly setting krky dy
@@ToorElectric sir wo dobra nhi aa
Thori bohat setting ki hai ap ki video kar
Is pe 585 k kitne solar lag sakte hain
18
Aap 20 Laga sakty ho safely
Onix pv 9000 be is app say connect ho jata hy?
Inverter ki manual book m likhi hogi uski app
Good
Thanks
Lahore mein installation krty hain ap?
Yes yh setup b lahore m he install kiya gya hai
Bhai maire pas 6kw ka hybrid system laga hoa hai but problem ye hai k din ki bharpoor garmi mein bhi wapda se sharing karta hai agar load 3kw chal raha ho to 2kw solar se chal raha hota hai jab k 1kw wapda se sharing ho rahi hoti hai plz solution batain
Angel wagra thk hai apka solar pr koi shadow to nhi?
@@ToorElectric nahi Bhai.. sub thek hai koi shadow bhi nahi
Or apny battery setting mn b ek mistake ki h fld Battery 🔋 ki setting voltage p rakhna chiya
Lithium battery p percentage rakhni chaiya
Ok sir jazak Allah
Zada sa zada kitny panl lag jayn gay is par 14 ya or bhe
18 b lag jygy
Agr 20 lagne ho to lag jaye gy ..550 waly@@ToorElectric
سر آپ 2 پینل مزید لگاسکتے ہیں 8 kw per backup اچھا پرفوم کرے گا
Ap kon c city se he?
Narowal
Energy ka mppt solar say current bar bar disconnect kar raha hai plzz masla batana
Sorry but energy company ka mppt use nhi kiya kabi so no idea
@@ToorElectric @MSulemanTech bhi mai nai multimeter say check kya tha jab mppt current nae laita solar say laikain solar say voltage a rahai hotai hai
Bhai earthing ka to bataen
Ok sir
6kv cost like this project
??
Aj kal 9 lakh
Dc dp me spd nhi lgayee
System ko danger he
Wo earthing time lagyga
Online kas tars kart hn
Wifi logger stick sy
Ya tu maj be pat os ka tareqa kaya ha. online karta kas tara hn
👍........
CT ko inverter k ander nhi rkhna chahiye,
Ok brother
@@ToorElectric
🌹
اسلام وعلیکم آپ 8 کلو واٹ کا لگا کر ڈے سکتے ہیں
Contact on WhatsApp
Not quality connection despite very expensive inverter
Kindly explain in details to help us
Installation not clean especially wires
Thanks for your feedback
Batteries quality poor
Ok sir
Bahi ap ka rabta numbar plez
03038086698
پلیز فون نمبر
03038086698
Brother aapka WhatsApp number
0303-8086698