Bhai plz meri help. Kar dain gay. Mary pas inverex ki lithum battery lagi hia 24v ki. Nitrox kay sat... Kia oc ka jo float charging enable rhakna chaya. Ya. Disable?
Kia aisa ho skta ha k battery only day time me solar panels sy charge ho or Wapda sy charge nahe ho? Mery pas invertex nitrox 5kw with 100ah 48v Lithium ion battery bank ha
Yes, battery seting 2 me ja kar Gird Charge and Gird Signle se click hata ker ok ker dy, phir khali day time solar plates py charge hogi, me bhi issi tarah he chala raha hn just day time solar py charge krta hn
AoA Thank you for the detailed video. I was having trouble setting my pylontech battery with this inverter and its fixed now. Now i want to use my battery at peak hours only. I will be very thankful if u could guide me how to setup this setting so that it is used only during 7pm-10pm and charges when solar generation is active.
U can.close KE/Wapda Charging by Entering in Battery Menu and uncheck wapda.charging - u cannot use battery on different timings u can use them in absence of KE/wapda
Sir mery pas zeiwnic lithium battery ha..is me v kam nhi hty same hi discharge hty..na battery off hti na low alarm deti.0% tk use ho jti. Light load ur heavy load both battery pe 0% tk use hty. Ma chahta hn k heavy load 70%=battery tk use ho us k bd light load on rhy bas
my nitrox doesn't charge the lithium battery 48v while load shedding, it continuously drain some power from the battery even tho there's enough sunlight
@@oaamer I am interested in applying INVEREX nitrox 5.2kw system with Pylontech 48v 100AH. What do you suggest? Would it be OK with li ion setting or BMS matching issues Would be faced. Kindly reply soon. Thanks
Thank you Brother Good information ❤
Màsha Allah great work Bhai
Nice work.👌🏻👌🏻
Aslam o Alaikum sir
Fronus matrix 5kw k sath narada 48v 100a ki 4 battery Bank lagiya ha os ki sitting Bata dein..
Shukria sir
ماشاءاللہ
Lithium battery dosn not need float charging.. u should use lithium battery setting otherwise ur battery cells will be damage
Ok
Bhai plz meri help. Kar dain gay. Mary pas inverex ki lithum battery lagi hia 24v ki. Nitrox kay sat... Kia oc ka jo float charging enable rhakna chaya. Ya. Disable?
نایٹروکس5kwکےساتھ535 باے فیشل مونو پرک ھاف کٹ کے 14 پینل لگا سکتے ھیں اسکے وولٹیج زیادہ تو نہیں ہوں گے؟
Sbu ki satting ap ulti nahi bata gae?
Kia aisa ho skta ha k battery only day time me solar panels sy charge ho or Wapda sy charge nahe ho? Mery pas invertex nitrox 5kw with 100ah 48v Lithium ion battery bank ha
Yes, battery seting 2 me ja kar Gird Charge and Gird Signle se click hata ker ok ker dy, phir khali day time solar plates py charge hogi, me bhi issi tarah he chala raha hn just day time solar py charge krta hn
@@junaidghaffarnizamani2542 Thank you so much me aj try krta hu qk battery charging 2kw consume krti ha
AoA
Thank you for the detailed video. I was having trouble setting my pylontech battery with this inverter and its fixed now.
Now i want to use my battery at peak hours only. I will be very thankful if u could guide me how to setup this setting so that it is used only during 7pm-10pm and charges when solar generation is active.
U can.close KE/Wapda Charging by Entering in Battery Menu and uncheck wapda.charging - u cannot use battery on different timings u can use them in absence of KE/wapda
Hello sir, How to resolve the Pylontech issue,,, I've an issue, Inverter shutdown on 95% battery with low DC volt fault... reply plz
@@RizwanKhan-en8ch Sir i havent installed with Paylon Tech so no information in this regards
@@RizwanKhan-en8ch use bms
Sir mery pas zeiwnic lithium battery ha..is me v kam nhi hty same hi discharge hty..na battery off hti na low alarm deti.0% tk use ho jti.
Light load ur heavy load both battery pe 0% tk use hty.
Ma chahta hn k heavy load 70%=battery tk use ho us k bd light load on rhy bas
Sir lithium k lea equalisation ki zarorat hoti hai kia?
Lithium mein BMS Builtion Hota hai is mein aypko equlization ki zerorat nehin pere ghi
Dear kya bettery sensor dip in battery acid or attached bettery body ? Pleased answer thanks
Attached with side of Battery
Nitrox 3KW with 4 Battery TX 3000 bataye please
my nitrox doesn't charge the lithium battery 48v while load shedding, it continuously drain some power from the battery even tho there's enough sunlight
Set Charge Perority Battery First
Sir... Tesla HLE ke battery voltage setting b batain
Inverter not Installed in My Circle of Customers
Li ion battery per li ion select nahi karain ge kya.
Nitrox sirif inverex ki lithium ko by default support kerta hai
Nice
why is lithium battery setting not working have you connected BMS cable
Sir Nitrox lithium battery setting will only support Inverex Lithium Battery As Per Company Own Policy
Do we need communication cable connect to battery if yes please tell us which port we should connect
Cable can be connected with Paylon Tec Lithium Battery
nitrox install kiya hai ab aik acha sa mobile b khared le
By this settings, you battery will surely be damaged. Use Lithium Ion option.
Nitrox dont support other lithium batteries on Lithium programing this programing is done on guideline from Inverex itself
@@AGradeSolarKarachi see the guidelines from manufacturer, Inverex is just a reseller. It does support Li ion batteries and shows all data in Li BMS.
@@oaamer I am interested in applying INVEREX nitrox 5.2kw system with Pylontech 48v 100AH.
What do you suggest?
Would it be OK with li ion setting or BMS matching issues Would be faced. Kindly reply soon.
Thanks
@@oaamer I have installed lithium battery with lithium settings but it doesn't show BMS. Do you know how to activate the lithium bms?
By passing batterie's own BMS is not a good practice. Better use lithium settings. Watch this to get an idea ruclips.net/video/_En0EU7ZXWE/видео.html
Rj 45 connection please
Sir apka num chaia mil sakhta hai