Hydraulic 2 Fixed and Variable displacement pump

Поделиться
HTML-код
  • Опубликовано: 13 авг 2022
  • There is a slight calculation error noticed at 10:00:00 minute due to editing error.
    Displacement = πr2l X no. of cyliders.
    The Final displacement mentioned in the video is 1.657inch cube, where the number of piston was considered as 6. During editing that part was deleted.
    Sorry for the inconvenience.

Комментарии • 55

  • @sumitsinghrajawat2733
    @sumitsinghrajawat2733 Год назад +2

    Great Video and wonderful way to explain the working of Piston pumps. One of the best video I have seen

    • @debasish61
      @debasish61  Год назад

      Thank you Sumit'ji for your motivation and support.
      I appreciate you so much.

  • @sumitsarkerjoy2279
    @sumitsarkerjoy2279 8 месяцев назад +1

    🎉 Thank You Sir. Lots Of Love from Bangladesh.🇧🇩

    • @debasish61
      @debasish61  7 месяцев назад

      Thank you Bhai. Please share my videos and.ask your friends to subscribe my channel.

  • @ashutoshsingh1137
    @ashutoshsingh1137 9 месяцев назад +1

    Sir please share why odd no piston used..

  • @dasbhabani031
    @dasbhabani031 11 часов назад +1

    Why did the odd numbers piston (7 or 9) be used in the axial piston pump.

    • @debasish61
      @debasish61  11 часов назад

      @@dasbhabani031
      *Why are the odd number of pistons incorporated in an Axial Piston Pump*
      1. With two pistons, there is one piston in the intake phase and another in the delivery phase. But during actually one piston cannot stay either in intake or delivery all the time.
      This results fluctuating fluid flow.
      But when you have three pistons, there is one piston in the intake phase and another in the delivery phase all the time. As a result, fluid flows in an unbroken motion so that it results into smooth running pumps.
      2. Even numbers of piston generates fluctuation in in flow rates or pressure which cause fluid Pulsations.
      But when there’s an odd number of pistons, each stroke provides smoother flow, hence there is no pulsation.
      3. As there is a consistent flow and with minimum vibration,
      machine gets less mechanical stress and even load distribution results parts reliability ie. longer parts life.

  • @amiteshranjan1345
    @amiteshranjan1345 5 месяцев назад +1

    Why we use odd no. Of piston in pump

  • @kumarbinodofficial4410
    @kumarbinodofficial4410 7 месяцев назад

    Apka samjhane ka tarika bahut badhiya🎉🎉🎉

    • @debasish61
      @debasish61  7 месяцев назад

      Thank you Bhai... kripaya apke dosto ke saath mera video share kariye aur mera channel ka subscriber barane.ke liye madat kijiye.

  • @shakirhussain775
    @shakirhussain775 Год назад +1

    Knowledgeable video sir...keep it up for growing our Knowledge

  • @rafikmohammed3181
    @rafikmohammed3181 Год назад +1

    Very useful video 👌🤝

    • @debasish61
      @debasish61  7 месяцев назад

      Thank you Bhai. Please share my videos and.ask your friends to subscribe my channel

  • @sunildas6409
    @sunildas6409 8 месяцев назад +1

    bohot bariya boss.

  • @kumarbinodofficial4410
    @kumarbinodofficial4410 7 месяцев назад

    Sir swing motor me cavitation line ka video banaye

  • @kanhaiyakeshari1017
    @kanhaiyakeshari1017 Год назад +1

    Sir vdp pump ko injection moulding machine me used karne se energy save hota hai ,ya vfd device lagakar motor ka rpm kam karke

    • @debasish61
      @debasish61  Год назад

      Whats App me.detailed reply mila hoga aapko.

  • @binodpandey8860
    @binodpandey8860 Год назад +1

    Hydraulic ven pump ka work kaya hai

    • @debasish61
      @debasish61  Год назад

      Koi bhi pump ka kam.hai flow dena

  • @rashidsulemani8179
    @rashidsulemani8179 Год назад +1

    Nice 👍👍👍 video

    • @debasish61
      @debasish61  Год назад

      Thank you. Please subscribe my channel and click the bell icon. Also ask your friends to subscribe my channel.

  • @skabdultawab19791
    @skabdultawab19791 29 дней назад +1

    Sir pls discuss close curit

    • @debasish61
      @debasish61  25 дней назад

      Abdul Bhai, aap kaha se ho ?

  • @physicsabhishek
    @physicsabhishek 11 месяцев назад +1

    Sir can we get a good presentation on variable delivery radial piston pump a.k.a HeleShaw Pump

  • @biplabkar5909
    @biplabkar5909 10 месяцев назад +1

    It is very helpful video but sir what is the roal of bias spring.pls explain it

    • @debasish61
      @debasish61  7 месяцев назад

      ruclips.net/video/BM8Yg9pf3CI/видео.htmlsi=EYCtvbcnMsVhIja4

    • @debasish61
      @debasish61  7 месяцев назад

      Thank you Bhai. Please share my videos and.ask your friends to subscribe my channel

  • @ashukumartyagi2469
    @ashukumartyagi2469 Год назад +1

    Sir tell approximately 5 differences between pressure relief and pressure reducing valve

    • @debasish61
      @debasish61  Год назад

      PRESSURE RELIEF VALVE :
      1.Normally closed type Valve
      2. Fitted in bypass line to reservoir tank
      3. Outlet is connected to reservoir tank
      4. It opens when the inlet pressure (System Pressure or Pilot Pressure) becomes more than preset value
      5. No bypass check valve is required.
      6. No external drain line.
      PRESSURE REDUCING VALVE :
      1. Normally Open type Valve
      2. Fitted in Main line to system
      3. Outlet is connected to the system
      4. It closes when outlet pressure( System Pressure or Pilot Pressure) becomes more than Preset value
      5. Bypass check valve installed.
      6. External drain line installed.

  • @sameersinha494
    @sameersinha494 Год назад +1

    Please make a video of pump used in injection molding machine

    • @debasish61
      @debasish61  Год назад

      Please WhatsApp me the pump details u want to know.

  • @kumarbinodofficial4410
    @kumarbinodofficial4410 7 месяцев назад +1

    Sir apka har video dekta hu

    • @debasish61
      @debasish61  7 месяцев назад

      Thank you Bhai.
      Kripaya apke dosto ko.mera video share kijiye aur subscriber barane ke liye madat kijiye.

  • @amirahmad5640
    @amirahmad5640 Год назад +1

    Sir,
    Pls explain denfoss close loop pump

    • @debasish61
      @debasish61  Год назад

      Please check my other videos on hydraulics where the close loop system is explained.

  • @harendrasaini2505
    @harendrasaini2505 7 месяцев назад +1

    Pls share the advantage and disadvantage of this type of pump, thanks

    • @debasish61
      @debasish61  7 месяцев назад +1

      Advantages :
      1. Hydraulic axial piston pumps are highly efficient due to their design, resulting in better energy utilization and reduced heat generation. Volumetric efficiency is 95% of the total efficiency of about 90%
      2. This high efficiency is critical for maintaining the overall performance and longevity of a hydraulic system.
      3. Hydraulic axial piston pumps offer variable displacement capabilities, allowing for precise control of fluid flow and pressure
      4. The precise control achieved through variable displacement contributes to better controllability of the hydraulic system.
      Disadvangaes
      1. Cost is a major disadvantage of a piston pump, as they can be expensive affairs up-front.
      2. Complexity of the machinery.
      3. If not properly lubricated, the mechanical parts within a piston pump are prone to wear due to the high pressure they are placed under and the psi they generate.
      4. Require a higher filtering accuracy and high level of maintenance standards.
      5. Higher operating cost compare to gear or vane type pump.

    • @harendrasaini2505
      @harendrasaini2505 7 месяцев назад +1

      @@debasish61 thank you very much 😊

    • @debasish61
      @debasish61  7 месяцев назад

      Please share my videos with your friends and ask your friends to subscribe my channel.
      Thank you so much.

  • @ahemadbhatti6686
    @ahemadbhatti6686 Год назад +1

    Sir jcb 3dx rpm miter bar bar band ho Jatan he

    • @debasish61
      @debasish61  Год назад

      1. Check Alternator W point to ECU and ECU to tachometer line
      2. May be the Alternator is having an issue
      2. ECU input need to check
      3. ECU output need to check
      4. Tachometer malfunctioning and it's input need to check.

    • @debasish61
      @debasish61  Год назад

      Please check and update me.

  • @harsharts-2010
    @harsharts-2010 Месяц назад +1

    Pump oil Nahin Utha raha hai

    • @debasish61
      @debasish61  Месяц назад

      Apne kya kya check Kia?

    • @harsharts-2010
      @harsharts-2010 Месяц назад

      Maine pump ke andar ka sara kit change kiya hun

  • @manmohan960
    @manmohan960 8 месяцев назад

    Sir Leakage line kyu rhta hai

    • @debasish61
      @debasish61  8 месяцев назад

      ruclips.net/video/wwEi7h7NHL4/видео.htmlsi=njq6Ub0jAAN_JCRg

    • @debasish61
      @debasish61  8 месяцев назад

      Check this video link.

  • @sayanbhukta2683
    @sayanbhukta2683 16 дней назад

    Great video,, can you please send me the what's app number,, i have a question regarding the pump callibration in Alluminium extrusion press

  • @silentman7546
    @silentman7546 Год назад

    Loading arm kesy work kerty hn

    • @debasish61
      @debasish61  Год назад +1

      Apka question samajh me.nahi aya.

    • @silentman7546
      @silentman7546 Год назад

      @@debasish61 jetty loading Arm per bnyia ga jo Terminal operation system hota ha loading arm lgy hoty hn crude oil chemicals ko ship ky Ander carry kerny ky lyia whn py hydraulic cylinder system lgy hb