Nanbare… nalla explain panunenga, oru sila corrections eruku 1. ABB CDP (control panel display) 2 types eruku Basic control panel and Assistance control panel, assistance control panel 3 line display and neriya options eruku so it is expensive. 2. VFD ratingla I2hd heavy duty currentna ennana oru semi conductorah over load paninomna athoda temperature romba sekrama increase agidum so athu thirumba cool agi safe operating levelku vara some time aagum, so ipo oru driveah rated currentla use panina neenga 8.8 Amps consume panalam, but unga applicationla over load iruntha neenga same driveah 150% overload panalam for 1 minute every 5 minutes, so 1 minuteku intha driveah 13.2 Amps currentla run panalam and then 5 minutesku 6.9 Ampsla run panalam, so overload timela increase aana heat ipo 5 minutesla kamiyana current flow agaranela cool agidum and this cycle can repeat. So heavyduty applicationsla motor power 3kW so motor nominal current 6.9Amps so neenga 150% load panamudium. It is same for All ACS drives such as ACS55,150,310,355,380,480,550,580,850,800 & 880
Bro i need u r what's app no naga field la 11kw 12 motor use panrom apo naga evlo kw vfd drive use pananum naga hevy duty high torque application ku use panrom apo naga ena requirements la vfd use pananum
Nanbare… nalla explain panunenga, oru sila corrections eruku
1. ABB CDP (control panel display) 2 types eruku Basic control panel and Assistance control panel, assistance control panel 3 line display and neriya options eruku so it is expensive.
2. VFD ratingla I2hd heavy duty currentna ennana oru semi conductorah over load paninomna athoda temperature romba sekrama increase agidum so athu thirumba cool agi safe operating levelku vara some time aagum, so ipo oru driveah rated currentla use panina neenga 8.8 Amps consume panalam, but unga applicationla over load iruntha neenga same driveah 150% overload panalam for 1 minute every 5 minutes, so 1 minuteku intha driveah 13.2 Amps currentla run panalam and then 5 minutesku 6.9 Ampsla run panalam, so overload timela increase aana heat ipo 5 minutesla kamiyana current flow agaranela cool agidum and this cycle can repeat. So heavyduty applicationsla motor power 3kW so motor nominal current 6.9Amps so neenga 150% load panamudium.
It is same for All ACS drives such as ACS55,150,310,355,380,480,550,580,850,800 & 880
Bro i have one doubt
Sir good evening ABB DCS800 பற்றிய முழு வீடியோ போடுங்கள்
Abb vfd remote on off and 0 to 20ma level swich and pressre switch setting video paduga sir ples
Bro yanaku ABB drive la scalar mode vector irruku ahthu yathuku bro...pls solluga
this drive is possible to use solar????????? if possible please tell what program want to change....
Acs 150 how to change directions rev to forward?
Single phaseல் எத்தனை HP வரை பயன்படுத்தலாம்.
Sir abb dirve 50hp dirve fitting panna E.B bill saving sir sollunga sir
Hai bro
Abb VFD
Input hz 48 to 63
Output 500 hz how ????
physical ah connection yepudi solluga bro, ir simple ah demo kuduga bro
Ji I want to know about abb Drive testing.if u have any manuals pls share
10 hp submersible motor 2 பேசில் இயக்க எவ்வளவு செலவாகும்?
Dear sir automatically speey increase and decrease what resion .pat meter also replaced sir what i do sir 45 kw drive sir
i am also facing same issue..kindly reply bro
Busbar differential protection practical with how do testing explain
Alarm intimation varuthu, eppadi cancel panrathu, alarm setting pathi oru video podunga
Sir, can you teach abb vfd to me?
Antha doubt link solluga bro
How to disable local mode
Fanuc , and Symends cnc pathi solluga and drive full details and explains
Bro i need u r what's app no naga field la 11kw 12 motor use panrom apo naga evlo kw vfd drive use pananum naga hevy duty high torque application ku use panrom apo naga ena requirements la vfd use pananum
acs 850 drive short circuit vardu bro how to solve
0 to 10vdc
4 to 20ma
Three types speed example 10hz , 20,hz and 50hz
Please explain
Anna atafdation enral enna anna
Bro how to contact you
Bro idhoda fault description pdf iruka
Panel trip alarm how to reset
No mistake bro
Sir...yella ABB drives oda parameters manual venum...adhukku yedhavadhu APPS irukka ...konjam susses pannunga sir ...
I am a control panel engineer ..i handled up to 845A drive full and full ABB dhan
So yennakku manual mattum irundha Nalla irukum ...
This vfd program
ACS 800&880 video poduga
Please sent parameter settings in tamil
ஏன் மூட்டு என்றால் என்ன அண்ணா
👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯
please real English subtitle