    @athish6716 3 года назад

    Nanbare… nalla explain panunenga, oru sila corrections eruku
    1. ABB CDP (control panel display) 2 types eruku Basic control panel and Assistance control panel, assistance control panel 3 line display and neriya options eruku so it is expensive.
    2. VFD ratingla I2hd heavy duty currentna ennana oru semi conductorah over load paninomna athoda temperature romba sekrama increase agidum so athu thirumba cool agi safe operating levelku vara some time aagum, so ipo oru driveah rated currentla use panina neenga 8.8 Amps consume panalam, but unga applicationla over load iruntha neenga same driveah 150% overload panalam for 1 minute every 5 minutes, so 1 minuteku intha driveah 13.2 Amps currentla run panalam and then 5 minutesku 6.9 Ampsla run panalam, so overload timela increase aana heat ipo 5 minutesla kamiyana current flow agaranela cool agidum and this cycle can repeat. So heavyduty applicationsla motor power 3kW so motor nominal current 6.9Amps so neenga 150% load panamudium.
    It is same for All ACS drives such as ACS55,150,310,355,380,480,550,580,850,800 & 880

  • @MADHUCHINNASAMY
    @MADHUCHINNASAMY Год назад

    Sir good evening ABB DCS800 பற்றிய முழு வீடியோ போடுங்கள்

  • @karthikrasu8580
    @karthikrasu8580 Год назад

    Abb vfd remote on off and 0 to 20ma level swich and pressre switch setting video paduga sir ples

  • @psychoenginer..930
    @psychoenginer..930 4 года назад +1

    Bro yanaku ABB drive la scalar mode vector irruku ahthu yathuku bro...pls solluga

  • @kozhanthaiveldeepa5317
    @kozhanthaiveldeepa5317 5 лет назад

    this drive is possible to use solar????????? if possible please tell what program want to change....

  • @mimuthukumar9098
    @mimuthukumar9098 2 года назад

    Acs 150 how to change directions rev to forward?

  • @ஜ.இம்ரான்
    @ஜ.இம்ரான் 5 лет назад +1

    Single phaseல் எத்தனை HP வரை பயன்படுத்தலாம்.

  • @arunkumarkumar9801
    @arunkumarkumar9801 3 года назад

    Sir abb dirve 50hp dirve fitting panna E.B bill saving sir sollunga sir

  • @mathavanr5460
    @mathavanr5460 2 года назад

    Hai bro
    Abb VFD
    Input hz 48 to 63
    Output 500 hz how ????

  • @vinothkumar7459
    @vinothkumar7459 5 лет назад +2

    physical ah connection yepudi solluga bro, ir simple ah demo kuduga bro

  • @marin2887
    @marin2887 2 года назад

    Ji I want to know about abb Drive testing.if u have any manuals pls share

  • @balasubramanian5325
    @balasubramanian5325 3 года назад

    10 hp submersible motor 2 பேசில் இயக்க எவ்வளவு செலவாகும்?

  • @prabakaranmanokaran684
    @prabakaranmanokaran684 2 года назад

    Dear sir automatically speey increase and decrease what resion .pat meter also replaced sir what i do sir 45 kw drive sir

    • @ajmalaja9888
      @ajmalaja9888 Год назад

      i am also facing same issue..kindly reply bro

  • @rajadm7624
    @rajadm7624 4 года назад

    Busbar differential protection practical with how do testing explain

  • @askarahamed3947
    @askarahamed3947 3 года назад

    Alarm intimation varuthu, eppadi cancel panrathu, alarm setting pathi oru video podunga

  • @manilakshmi6118
    @manilakshmi6118 Год назад

    Sir, can you teach abb vfd to me?

  • @ajmalaja9888
    @ajmalaja9888 Год назад

    Antha doubt link solluga bro

  • @ukkirapandianp1856
    @ukkirapandianp1856 2 года назад

    How to disable local mode

  • @iyanthiraulagam2514
    @iyanthiraulagam2514 5 лет назад

    Fanuc , and Symends cnc pathi solluga and drive full details and explains

  • @teslathamizh1480
    @teslathamizh1480 3 года назад

    Bro i need u r what's app no naga field la 11kw 12 motor use panrom apo naga evlo kw vfd drive use pananum naga hevy duty high torque application ku use panrom apo naga ena requirements la vfd use pananum

  • @vijayagamudayar
    @vijayagamudayar 4 года назад

    acs 850 drive short circuit vardu bro how to solve

  • @-samy-74
    @-samy-74 3 года назад

    0 to 10vdc
    4 to 20ma
    Three types speed example 10hz , 20,hz and 50hz
    Please explain

  • @பேசும்
    @பேசும் 3 года назад

    Anna atafdation enral enna anna

  • @yuvarajc8951
    @yuvarajc8951 4 года назад

    Bro how to contact you

  • @Eng853
    @Eng853 5 лет назад

    Bro idhoda fault description pdf iruka

  • @mohammedfaizer1064
    @mohammedfaizer1064 4 года назад

    Panel trip alarm how to reset

  • @vrenjoyourlife747
    @vrenjoyourlife747 2 года назад

    No mistake bro

  • @sharvansaro2818
    @sharvansaro2818 5 лет назад

    Sir...yella ABB drives oda parameters manual venum...adhukku yedhavadhu APPS irukka ...konjam susses pannunga sir ...

    • @sharvansaro2818
      @sharvansaro2818 5 лет назад

      I am a control panel engineer ..i handled up to 845A drive full and full ABB dhan

    • @sharvansaro2818
      @sharvansaro2818 5 лет назад

      So yennakku manual mattum irundha Nalla irukum ...

  • @nagendranp7398
    @nagendranp7398 2 года назад

    This vfd program

  • @dhinakaranb4853
    @dhinakaranb4853 5 лет назад

    ACS 800&880 video poduga

  • @thirusraj7226
    @thirusraj7226 4 года назад

    Please sent parameter settings in tamil

  • @camilas4227
    @camilas4227 4 года назад

    ஏன் மூட்டு என்றால் என்ன அண்ணா

  • @veerav.k.gaundar5843
    @veerav.k.gaundar5843 5 лет назад

    👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯👯

  • @labibahmed6140
    @labibahmed6140 4 года назад

    please real English subtitle