HARMAN KARDON DEVICE SLEEP AFTER BOOT. AUTOMATIC SHUTDOWN

Поделиться
HTML-код
  • Опубликовано: 8 сен 2024
  • The problem with this HK receiver would shutdown with device sleep error on the display plus yellow arrange flashing. After troubleshooting, the culprit was a faulty over heating detection circuit board. Watch how I solved the issue easily and 100%. Thank you guys for your support and subscribe for more videos in the making.

Комментарии • 33

  • @mauriciomanchego6998
    @mauriciomanchego6998 Год назад +2

    Buenas a todos, con el respeto del dueño del video, me llegó al taller uno con la misma falla y despues de revisar la potencia, revisar el sensor de calor y las revisiones usuales que uno hace en taller todo parecía normal. La solución fue limpiar la tarjeta lógica, donde vienen los HDMI, con detergente en polvo y un cepillo de dientes, luego con la pistola de aire caliente, secar unos 15 minutos y la falla quedó resuelta. En mi caso la tarjeta estaba pegajosa y al parecer el problema era suciedad

  • @RahulKumar-tb2uf
    @RahulKumar-tb2uf Год назад

    Thanks sir

  • @janvincentvillanueva2954
    @janvincentvillanueva2954 10 месяцев назад

    boss same issue yun avr 161s ko, paano i fix ,pwede makita ng clear or diagram?

  • @ozidarkside4141
    @ozidarkside4141 7 месяцев назад

    Hello, I have the AVR161s model. It says sleep mode and then the orange light flashes. What is the solution?

    • @vitronicstech2633
      @vitronicstech2633  7 месяцев назад

      There is short circuit in the circuit board.

    • @vitronicstech2633
      @vitronicstech2633  7 месяцев назад

      Check all output power transistors with multimeter and the fusable greenish resistors for open and short cct

  • @219jujis
    @219jujis Год назад

    yo le puse un ventilador encima a la velocidad alta y si funciono ya no se apago

  • @zaverimail
    @zaverimail Год назад

    Sir my AVR 130 surround working main tower speakers not working what to do please advise

    • @vitronicstech2633
      @vitronicstech2633  7 месяцев назад

      You have faulty audio output IC, check the main amplifier circuit especially the mosfet for short circuit

  • @chidiebubenwaohiri6256
    @chidiebubenwaohiri6256 2 года назад

    Bro my amplifier is having the same issue like yours, I tried to watch what you did to fix it. But I didn’t see what you did as the video is not clear enough. Can you guide me pls..

    • @stevevillier472
      @stevevillier472 2 года назад +1

      Please check heat detector circuit, system is shutting down because it's designed to scan all components for proper operation, failure of any triggers safety mode. In my case I replaced heat detector circuit with 22k resistor between 5v supply and signal

    • @VikingHeroe
      @VikingHeroe 2 года назад

      @@stevevillier472 I have the same problem, I did the 22k resistor between pin 1 and pin 3, problem still remain. Is there something I missed?

    • @vitronicstech2633
      @vitronicstech2633  2 года назад

      Identify 5v and signal, check if you've between 1-4v on the signal terminal during powering.

  • @babup.a.7359
    @babup.a.7359 4 месяца назад

    Where is service centre?

  • @siphosokoyi7295
    @siphosokoyi7295 2 года назад

    Where is that 22k resistor located

    • @stevevillier472
      @stevevillier472 2 года назад

      You put 22k resistor across 5v and heat detect signal

    • @erniecustodio7404
      @erniecustodio7404 2 года назад +1

      I try but not working,..

    • @vitronicstech2633
      @vitronicstech2633  7 месяцев назад

      check if we have 5v as indicated on the board, then use a 22k resistor to drop the voltage to around 2.5v normal to operate the temperature detection cct.

  • @mariomachado7948
    @mariomachado7948 2 года назад +2

    Péssimo video. Mal filmado e explicado. Poderia não ter sido gravado. Além disso aparece uma outra mão com um placa que não é do aparelho

    • @guinamax4390
      @guinamax4390 Год назад

      Tu conseguiu arrumar o seu? Estou com o mesmo problema aqui ....

  • @ernestosantuyo7705
    @ernestosantuyo7705 5 месяцев назад

    Sir can I have your number, Meron sana akong ipapagawa same problem po nyan

  • @herywaluyo1074
    @herywaluyo1074 2 года назад

    What is you repair ?

    • @vitronicstech2633
      @vitronicstech2633  2 года назад +3

      Heat detector circuit fault. Replaced a 2.2k resistor between 5v and output

    • @herywaluyo1074
      @herywaluyo1074 2 года назад

      Same with my amplifier .. This power shut down ... (Device Sleep) . Jumper resistor 22k not working

    • @herywaluyo1074
      @herywaluyo1074 2 года назад

      This out put heat detector 2,2volt( DC)

    • @stevevillier472
      @stevevillier472 2 года назад

      It should be a 2.2k

  • @breadsticks98
    @breadsticks98 Год назад

    Haha 😂 Jamaica

  • @ManishRaj-if6vb
    @ManishRaj-if6vb 2 года назад

    22 ke register kha lagana hai

    • @vitronicstech2633
      @vitronicstech2633  2 года назад

      Use English kindly

    • @vitronicstech2633
      @vitronicstech2633  2 года назад +1

      Between 5v and detect signal

    • @mahendealwis9538
      @mahendealwis9538 11 месяцев назад

      Hi, i have Hk 161with the same issue. Im not an electronic expert, so can you show me where the 22k located?

  • @albertoventura3764
    @albertoventura3764 8 месяцев назад

    Que mal video, no le entendí nada de lo q hizo, para acabar no explica.

  • @imranmiamia1170
    @imranmiamia1170 2 года назад

    Vaiya apka nambar diye ga