В инструкции по ремонту кондиционера Toshiba написан как вариант разрядки силовых конденсаторов - с помощью паяльника. < Discharging method > 1. Remove the inverter cover (plating) by opening four mounting claws. 2. As shown below, connect the discharge resistance (approx. 100Ω40W) or plug of the soldering iron (вилку от паяльника) to voltage between + - terminals of the C14 (“CAUTION HIGH VOLTAGE” is indicated.) electrolytic capacitor (500µF/400V or 760µF/400V) on P.C. board, and then perform discharging.
В инструкции по ремонту кондиционера Toshiba написан как вариант разрядки силовых конденсаторов - с помощью паяльника.
< Discharging method >
1. Remove the inverter cover (plating) by opening four mounting claws.
2. As shown below, connect the discharge resistance (approx. 100Ω40W) or plug of the soldering iron (вилку от паяльника) to
voltage between + - terminals of the C14 (“CAUTION HIGH VOLTAGE” is indicated.) electrolytic capacitor
(500µF/400V or 760µF/400V) on P.C. board, and then perform discharging.
Здравствуйте, для еср метра LCR -t4 защиту от разряда конденсатора не пробовали делать?
Нехера не понятн, но очень интересно
А можно универсальную разрядку сделать, чтоб от 12 до 380 в разряжало?
можно взять мощный резистор, 1-2ВТ, или несколько. сгорят вдруг - не жалко. можно кстати прозвонкой мультиметра разрядить конденсатор.
Ёлки-палки первый способ лучше
самый геморройный метод.
Зачем все так сложно то?
а как не сложно? Ну кроме как отверткой закоротить