  • @ahmedabdulkareem6481
    @ahmedabdulkareem6481 4 года назад +3

    I think the reason why for the fluctuation is your output is from an HMI which means has a processor and frequency, the input module of the AB has a scan frequency too, so both processors will meet sometimes in a point where no output from the HMI while the input is scanning, better to use a true analog like a battery with a resistor for things like this, better to use current to begin with to get better value at longer cables, thanks for the video buddy

  • @Manjinder_Pawar
    @Manjinder_Pawar 3 года назад

    Vlad you are doing great work ... best wishes to you

  • @muhammadatif1696
    @muhammadatif1696 5 лет назад +3

    Splendid!
    Do make the video for the Analog Output Signal.
    Thanks!

  • @electrichorror6642
    @electrichorror6642 5 лет назад

    good vid. Like it how you debugged it and found the issue some people would have solved it and not showed it

  • @amreshadwikvirtual
    @amreshadwikvirtual 2 месяца назад

    Exlnt explanation👍

  • @improviser100
    @improviser100 3 года назад +3

    By the way, the catalog number for the expansions are also on the inside of the cover. Bottom corner.

  • @CADELZOGMR
    @CADELZOGMR 5 лет назад +1

    Thanks, buddy. You helped me a lot.

  • @sahand944
    @sahand944 6 месяцев назад

    very helpful. thanks

  • @FollowerofYahuwah
    @FollowerofYahuwah 4 года назад +1

    What is the name of the video that covers the hmi and the analog programming you touched on a little. I want to figure out how to do the hmi analog control and how to create the ladder logic for it. Why does it seem NO ONE really covers the actual breakdown of the ladder logic for those of us who are new? Everyone touches on it back never fully goes into it including examples of how to write and use the logic.

  • @PLCProgrammingCourses
    @PLCProgrammingCourses 4 года назад

    Very useful stuff 😊

  • @naop86
    @naop86 4 года назад

    Very useful thank u!!

  • @plcplc3138
    @plcplc3138 4 года назад

    Cool videos, brilat brain!

  • @benc8030
    @benc8030 5 лет назад

    Hi Vlad, Can you please made a video of selecting job thru an array of database with many attributes

  • @amreshadwikvirtual
    @amreshadwikvirtual 3 года назад

    I want know how to change the range or scale of a particular AI in RS logix5000. Could u plz help me on that?

  • @rachidajewher8649
    @rachidajewher8649 4 года назад

    do you know how i'm gonna scale the analog signal coming from a preamp to an adc in audio ? do you know any analog brand for this

  • @rahulmaharnor9000
    @rahulmaharnor9000 4 года назад

    do more videos on Communication protocol in AB

  • @megrobelly
    @megrobelly Год назад

    what hmi is that?

  • @selvaganeshs4145
    @selvaganeshs4145 5 лет назад

    Kindly make video for analog output also

  • @repro-rt6lu
    @repro-rt6lu 3 года назад

    How are u able to change to a real #?

  • @LololeoLolo
    @LololeoLolo 4 года назад

    can i add a analog module to a compactlogix 5069 on ONLINE MODE without going off with the plc ???

    • @SolisPLC
      @SolisPLC  4 года назад

      No, you can't add modules online.

    • @SolisPLC
      @SolisPLC  4 года назад

      Although Rockwell does allow you to add external devices online. It may be possible... I'd have to check.

    • @LololeoLolo
      @LololeoLolo 4 года назад

      @@SolisPLC i have an entire water treatment plant operation running under a compact logic 5069 ( with their respective module ) I’m gonna have to shut down the plant to install a new analog if8 module ?

    • @SolisPLC
      @SolisPLC  4 года назад +3

      @@LololeoLolo by the NEC (electrical code), you need to shut down the panel to perform any modifications even at low voltages. Regardless of what can be done with the module, this isn't something that should ever be done live... For equipment and personnel protection.

  • @ZohaibJahan
    @ZohaibJahan 5 лет назад

    Any other way of scaling Analog values apart from CPT?

    • @Davedwin
      @Davedwin 3 года назад

      I know you posted this a year ago, but ... For my Analog mA signals, the designers of our logic created some Analog Conversion function blocks. We put the RAW input into a function block (using values from the chart seen here). I then send that converted value to another FB that converts that to the value for the instrument (psi, gpm, deg, etc.).

    • @GuidoCarmona
      @GuidoCarmona 4 месяца назад

      yes, with SCP AddOn Instruction.