You are totally mistaken brother, actually We cut pile head to reach cut off level of pile but for contaminated concrete best solution is overflow of concrete. So then why we need concreting up to top level of steel cage or may be above steel cage level ? The reason is In areas where water level is high casing of pile doesn't sticks at the required level it slips down during drilling, steel cage lowering and further slips down while concreting of pile so we need that area to be filled and compacted properly thats why cut off level remains down and also we need to get rid of contaminated concrete we do concrete upto top of pile cage or above to ensure sound concrete so because of this complex situation we do all of this.
Cast isliye karte hain ki jo apka waste material kaise ki mud, bentonite or polymer and water mix hokar bahar cut off level ke upar aa jayen jisse jo wasting concrete usko chipping karke bahar nikal den aur ek stable pile ka nirman ho sake.Cut off level,hum design ke basis par decide karte hain uske baad cutoff level se lagbhag 1 to 1.5 m extra concrete ke casting karte for chipping of pile.
Sir maine aapke chanel se bahut kuch sikha h lekin sir mujhe surveying ke liye koi aisa video nahi mila jisse me serveying sikhu sir please koi aisa video banaye jisse mai ek surveyar ban saku aapke is video se bahut sare engineer sikh jayenge
Sir hook length kaise nikalte hai mere site pe jo chl rha hai aapko batata hu CTL@31.OO5. and COL@ 30.321 to mai hook length nikalta hu CTL-COL-1.05 JO ATA HAI VAHI hai ya kuch aur plz mujhe suggest kro clear cut
i seen ur all videos it is all for usefull to us, so please sent me the construction field excavation means starting from upto Ground floor videos i need please sent me in tamil.
A development length can be defined as the amount of reinforcement(bar) length needed to be embedded or projected into the pile cap or column to establish the desired bond strength between the concrete and steel (or any other two types of material).
SIr , I am working on a test pile cage with 2 m dia. It has transverse reinforcements on top. Can you please explain at what point do we install it in the cage . Since the tremie pipe has a diameter more than the spacing of the transverse reinforcements, we cant put it through it. And we cant remove the tremie pipe to make the transverse reinforcement since extra concrete flushing needs to be done. Please clear this doubt.
Ye tuh samjh gye kyu hota , but sir kase implement Karenge....volume furstum nikale ke volume aajaye hopper ka sir can u explain dememsion of trime pipe,. Sir u video always help us...U doing nice job
Sir ji volume of Hooper kaise nikalenge dijia aur uska basis kitna length breadth height rakenge trimmie pipe ka niche woh bhi process bol dijia aur last ld kitna rakenge approximately hiath kitna min rakhna Hai as per is code Tora dijia ek compact video ban jyega
Sir very nice vedio.Alots of thank. But I wanted to know one thing that why the LD is said as development length when D comes first and L has comes last.
He is explaining everything same as on site procedure 👍👍
Thxx... Naya sikha aaj maine
Must share with ur friends and juniors to help them
You are totally mistaken brother, actually
We cut pile head to reach cut off level of pile but for contaminated concrete best solution is overflow of concrete. So then why we need concreting up to top level of steel cage or may be above steel cage level ?
The reason is In areas where water level is high casing of pile doesn't sticks at the required level it slips down during drilling, steel cage lowering and further slips down while concreting of pile so we need that area to be filled and compacted properly thats why cut off level remains down and also we need to get rid of contaminated concrete we do concrete upto top of pile cage or above to ensure sound concrete so because of this complex situation we do all of this.
Thanks for concept 🎉
Best technical discussion . thanks
Thanks sir for the INFORMATION. Keep it up😊
Main 4 manzila Ghar bana Raha hu... piling depth 20 feet hai....Kya isake liye bhi mujhe piling head cut karna chahiye impurities hatane ke liye ...
🙏
👌👌👌👌👌
So nice video
So nice explanation 👏👏👏
Excellent sir
Narayan Bless 🙏 You
Thank you so much Sir ! Mujhe bahut din pata chala hai !
Verryhelpful for non engineering persos
very informative, thanx
Great explanation
I remember my examiner asking me this question and i had no answer.
Again great video sir.
Very nice explanation.
You are 100 times better than Baklol khan teacher..who targets one COMMUNITY and talking useless.
very nice vedio
Very nice sir
Brilliant
Volume of hopper can be either frustum of cone or trapezoidal formula.
Sir, cut off level ke uper cast hi kyu kerte h and bentonite or water tho casting jese jese hothi h vo bahar nikal jatha h tho phir cast kerna hi kyu?
Cast isliye karte hain ki jo apka waste material kaise ki mud, bentonite or polymer and water mix hokar bahar cut off level ke upar aa jayen jisse jo wasting concrete usko chipping karke bahar nikal den aur ek stable pile ka nirman ho sake.Cut off level,hum design ke basis par decide karte hain uske baad cutoff level se lagbhag 1 to 1.5 m extra concrete ke casting karte for chipping of pile.
Great
Sir, Ek doubt hai. Agar woh pile head part todna hi hai, toh waha tak cast hi kyu karte hai? Hum cut off level pe casting kyu nahi rokte?
Is video ko agar ap dhayan se dekhengi to apko answer mil jayega.. maine ye bataya hai isme
Because , bore kai andar jitna v sallury rahai ga yo bahar aa jayai ga isiliye hum casting COL sai jada kartai hai
@@LearningCivilTechnology sir aapne kaha water sulary upper aata hy.but sir me kya water bharty hy kya
For Green concrete and smooth work we did it from cut off level
Pile ka concrete pouring complete hogaya to use casing level se ground level tak Jcb Ya kisi aur se hate sakte h to kitne time bad
Sir maine aapke chanel se bahut kuch sikha h lekin sir mujhe surveying ke liye koi aisa video nahi mila jisse me serveying sikhu sir please koi aisa video banaye jisse mai ek surveyar ban saku aapke is video se bahut sare engineer sikh jayenge
My doubt solved 🙏
Yahi cheez ko diaphragm me follow kiya jata he kya?
Thank you sir, for nice explanation
Sirji please explain this concept with dimensions to clear understanding .
Very good topic selected .. thank you sir ji
Very good information sir
Thanks sir for this video.
If possible please make a another video on piling work (Technical points as per is code)
Welcome bos
Thank you 😇
Pile cap ko jo dismental krte he bo bill me alag se milti he ya nhi or iska IS code kya he
Thanks
Sir hook length kaise nikalte hai mere site pe jo chl rha hai aapko batata hu CTL@31.OO5. and COL@ 30.321 to mai hook length nikalta hu CTL-COL-1.05 JO ATA HAI VAHI hai ya kuch aur plz mujhe suggest kro clear cut
Explain relation of Development length at top n Vol A
Ventonite ka kyo use karte h
Should the TREMIE PIPE be lifted a little bit before every dropdown of concrete from hopper?
Jia Jia yes tremme pipe should be lifted so that concrete easily dropdown to the bore and treme pipe will be free
Soumen Middey thanx.. if possible kindly share a full video of piling...
i seen ur all videos it is all for usefull to us, so please sent me the construction field excavation means starting from upto Ground floor videos i need please sent me in tamil.
Sir pile ko is code ke hisab se kitna dismentel harna chahiye
Hopper volume kivabe ber korbo?
Sir quatity of steel on site piling mei kaise check kru uspe ek video bnao na . I mean i calculated the quantity abhi usko kaise compare kru.
Sir hopper ka volume pe video chahiye sir plz help me
Banaya hua hai bhai... Search kijiye ap mil jayega
But how do we know that trimie pipe is inside concrete or not, because we can't see at that depth.
Sir Jo pipe ke niche space hai woh kaise chodoge hum. Kyuki jab pile bore karte hai woh cylindrical hi jayagi na
Very Goood
Development length Kya hota h
Sir
I am continuous follower of your channel.
A development length can be defined as the amount of reinforcement(bar) length needed to be embedded or projected into the pile cap or column to establish the desired bond strength between the concrete and steel (or any other two types of material).
Really nice and very useful video. Thanks a lot. #Success555
awesome. sir ji
Watertable high h agar, to tremiepipe thoda bhi upar rakhne se Paani jayga pipe me. Fir concreting kaise hoga?
good work
nice.. I want to more video
Sir tremie pipe termination level se kitna up rkhana hai , ye aapne apne man se bataya ki IS code bhi padha hai, mr L&T
Sir pile ka level kaise lete hai ek video banaiye please..
Can you upload the way to make the BBS of PIER CAP
Hai video...Sir ne upload kiya tha
Kaise nikalte h volume Hopper
Nice
Sir hamare piling me pura pani bhar gya tha .mistri ne usi me sukha masala diya kya kare sir
Good evening sir i am very eager to know about you & your profile sir please share with me for this I will always thankful to you sir
SIr , I am working on a test pile cage with 2 m dia. It has transverse reinforcements on top. Can you please explain at what point do we install it in the cage . Since the tremie pipe has a diameter more than the spacing of the transverse reinforcements, we cant put it through it. And we cant remove the tremie pipe to make the transverse reinforcement since extra concrete flushing needs to be done. Please clear this doubt.
hmmm. that's a tough one. just eyeball it.
bentonite test kese kiya jata h sir jee
Which foundation is best pile or raft???
Pile
Kitna bentonite require hota h???
Ye tuh samjh gye kyu hota , but sir kase implement Karenge....volume furstum nikale ke volume aajaye hopper ka sir can u explain dememsion of trime pipe,. Sir u video always help us...U doing nice job
Hopper ka volume thora dal dijiye ya to link de dijiye
Ap is video ko dekhe ruclips.net/video/e6WmvCZkhdY/видео.html
Sir please provide one video for how many bags are bentonite in 30 mtr pile 🙏 we ha requested
Sir ji volume of Hooper kaise nikalenge dijia aur uska basis kitna length breadth height rakenge trimmie pipe ka niche woh bhi process bol dijia aur last ld kitna rakenge approximately hiath kitna min rakhna Hai as per is code Tora dijia ek compact video ban jyega
Plz make a vedio regarding deep excavation for raft foundation
Ok
Nice sir
nice sir aur banaiye civil ke video
Pile k upper ak full video banaie.. trimme pipe opening ka video banake dijie
Sir pile ke andar water q bharty hy.
Mukesh ji thank you
Kya aap tender filling aur quotation submission video upload kar sakte hai
Sir kitna depth tak pile head cutting kartehn ?
Jagabandhu Behera it will mentioned in construction drawing
Good
👍👍
What is cutoff level....?
Video bana dunga ispe jald
@@LearningCivilTechnology please.......kahin nhi mil rha.......poora smjh bhi nhi aa rha shi se
Hope video jald aayegi
Tq Bro...
Sir pile ka bbs bataye. Pile 30 m and dia 1200
hopper volume kaisa nikalna hai sir
sir hopper k size kuch fix hota hai ya different sizes me available ho jaate hai
or plz make a video to how to find the volume
Alag alag hote hai
sir,how to find hopper volume and reinforcement requirement
Bore depth-Cone+lap =reinforcement length eg: depth=10m, lap=50 cm, Chisel Cone=30cm =10.50m-.30=
10.20 m Reinforcement length..
How to cast pile when water table is to high....is it any tech to remove water before casting pile
see tremie pipe method
सर बैडोनाइट क्या है
Thank You Sir..........
Why provide bentonite before casting... And what will be the duration of of bentonite...
Bentonite is used for the stability of soil under pile so that soil can not fall or mix with the concrete while pouring
@@sarimkhan6640 thanks dear... Can you tell me about timing duration please...
Sir very nice vedio.Alots of thank.
But I wanted to know one thing that why the LD is said as development length when D comes first and L has comes last.
Sir bentonite clay kyu dalte hai
Commonly Kidhar strata sand athey hi udhar Bentonite use karthe hi nahi tho bore ko cave in ayegaa...
Agar cc cutoff level tak he bhare
Thank you sir
If the total depth of the is 27.26 meter. How much of the gap b/w the pile bottom.
Sir ye kaha se bata rahe ho aap ,ye kha likha hai, IS Codes ki videos lekar ao..
Bhai , practical Hain ,
Survey r.l ,tbm nikalna bataye
Cut level calculation karia sir.with drawing.
Sir hopper ka volume kaise nikalenge
ruclips.net/video/e6WmvCZkhdY/видео.html es link pr click kr Dekh lo aap
👍👍👍👍👍
Sir, app coarse aggregate nd fine aggregate combined graduation calculations ke uper ak video banaiye...please bohut help hoga
Please pile casting process video share
how to calculate tha hopper volume?