Why We Break Pile Head After Casting | Head Cutting Of Pile

Поделиться
HTML-код
  • Опубликовано: 12 дек 2024

Комментарии • 186

  • @karthik133
    @karthik133 3 года назад +7

    He is explaining everything same as on site procedure 👍👍

  • @mr.alankar3059
    @mr.alankar3059 4 года назад +1

    Thxx... Naya sikha aaj maine

  • @asifbarki2418
    @asifbarki2418 3 года назад +3

    You are totally mistaken brother, actually
    We cut pile head to reach cut off level of pile but for contaminated concrete best solution is overflow of concrete. So then why we need concreting up to top level of steel cage or may be above steel cage level ?
    The reason is In areas where water level is high casing of pile doesn't sticks at the required level it slips down during drilling, steel cage lowering and further slips down while concreting of pile so we need that area to be filled and compacted properly thats why cut off level remains down and also we need to get rid of contaminated concrete we do concrete upto top of pile cage or above to ensure sound concrete so because of this complex situation we do all of this.

  • @cookwithavi1
    @cookwithavi1 Год назад +1

    Thanks for concept 🎉

  • @upendradora3152
    @upendradora3152 2 года назад +1

    Best technical discussion . thanks

  • @Tanwar_arpit
    @Tanwar_arpit 2 года назад +1

    Thanks sir for the INFORMATION. Keep it up😊

  • @SurajRaj-ji5ev
    @SurajRaj-ji5ev 3 года назад +1

    Main 4 manzila Ghar bana Raha hu... piling depth 20 feet hai....Kya isake liye bhi mujhe piling head cut karna chahiye impurities hatane ke liye ...

  • @hajeemohammed9912
    @hajeemohammed9912 4 года назад +2

    🙏
    👌👌👌👌👌
    So nice video
    So nice explanation 👏👏👏

  • @shaileshchawan1782
    @shaileshchawan1782 3 года назад +1

    Excellent sir

  • @miteshparmar2015
    @miteshparmar2015 2 года назад +1

    Narayan Bless 🙏 You

  • @niti1076
    @niti1076 4 года назад +1

    Thank you so much Sir ! Mujhe bahut din pata chala hai !

  • @srinivasnjobs4299
    @srinivasnjobs4299 3 года назад +2

    Verryhelpful for non engineering persos

  • @shashikantarath2567
    @shashikantarath2567 3 года назад +1

    very informative, thanx

  • @Gorusuur
    @Gorusuur 3 года назад +1

    Great explanation

  • @faizankirmani6266
    @faizankirmani6266 2 года назад +1

    I remember my examiner asking me this question and i had no answer.
    Again great video sir.

  • @farhanhafiz6088
    @farhanhafiz6088 3 года назад +2

    Very nice explanation.
    You are 100 times better than Baklol khan teacher..who targets one COMMUNITY and talking useless.

  • @anuragpandey5333
    @anuragpandey5333 4 года назад +1

    very nice vedio

  • @RaviPCECV
    @RaviPCECV 5 лет назад +1

    Very nice sir

  • @cutenessoverload2409
    @cutenessoverload2409 3 года назад +1

    Brilliant

  • @srinivasan8076
    @srinivasan8076 2 года назад +1

    Volume of hopper can be either frustum of cone or trapezoidal formula.

  • @bitumundra3748
    @bitumundra3748 5 лет назад +2

    Sir, cut off level ke uper cast hi kyu kerte h and bentonite or water tho casting jese jese hothi h vo bahar nikal jatha h tho phir cast kerna hi kyu?

    • @shivpratap6630
      @shivpratap6630 5 лет назад +1

      Cast isliye karte hain ki jo apka waste material kaise ki mud, bentonite or polymer and water mix hokar bahar cut off level ke upar aa jayen jisse jo wasting concrete usko chipping karke bahar nikal den aur ek stable pile ka nirman ho sake.Cut off level,hum design ke basis par decide karte hain uske baad cutoff level se lagbhag 1 to 1.5 m extra concrete ke casting karte for chipping of pile.

  • @rajaneja4390
    @rajaneja4390 2 года назад +1

    Great

  • @harshadamote6818
    @harshadamote6818 3 года назад +2

    Sir, Ek doubt hai. Agar woh pile head part todna hi hai, toh waha tak cast hi kyu karte hai? Hum cut off level pe casting kyu nahi rokte?

    • @LearningCivilTechnology
      @LearningCivilTechnology  3 года назад +1

      Is video ko agar ap dhayan se dekhengi to apko answer mil jayega.. maine ye bataya hai isme

    • @er.rahulkumar4396
      @er.rahulkumar4396 3 года назад +1

      Because , bore kai andar jitna v sallury rahai ga yo bahar aa jayai ga isiliye hum casting COL sai jada kartai hai

    • @MohammadShahid-xn3jd
      @MohammadShahid-xn3jd 3 года назад

      @@LearningCivilTechnology sir aapne kaha water sulary upper aata hy.but sir me kya water bharty hy kya

    • @sukhangsusekharjena5705
      @sukhangsusekharjena5705 Год назад

      For Green concrete and smooth work we did it from cut off level

  • @ravishankersah5106
    @ravishankersah5106 4 года назад

    Pile ka concrete pouring complete hogaya to use casing level se ground level tak Jcb Ya kisi aur se hate sakte h to kitne time bad

  • @rakeshbaghel789
    @rakeshbaghel789 6 лет назад

    Sir maine aapke chanel se bahut kuch sikha h lekin sir mujhe surveying ke liye koi aisa video nahi mila jisse me serveying sikhu sir please koi aisa video banaye jisse mai ek surveyar ban saku aapke is video se bahut sare engineer sikh jayenge

  • @user-fx2oo3bi9c
    @user-fx2oo3bi9c 3 года назад +1

    My doubt solved 🙏

  • @noor-sf8yq
    @noor-sf8yq 3 года назад

    Yahi cheez ko diaphragm me follow kiya jata he kya?

  • @unityindiversity1356
    @unityindiversity1356 6 лет назад +1

    Thank you sir, for nice explanation

  • @umapathitb4516
    @umapathitb4516 3 года назад

    Sirji please explain this concept with dimensions to clear understanding .

  • @steelwedge897
    @steelwedge897 6 лет назад

    Very good topic selected .. thank you sir ji

  • @ribhuraj3663
    @ribhuraj3663 6 лет назад

    Very good information sir

  • @susantamalas
    @susantamalas 6 лет назад +6

    Thanks sir for this video.
    If possible please make a another video on piling work (Technical points as per is code)

  • @sudarsanagogoi8320
    @sudarsanagogoi8320 4 года назад

    Thank you 😇

  • @jafarhusain3201
    @jafarhusain3201 6 лет назад

    Pile cap ko jo dismental krte he bo bill me alag se milti he ya nhi or iska IS code kya he

  • @Assam-bt1dl
    @Assam-bt1dl 6 лет назад

    Thanks

  • @jagreshvishwakarma6198
    @jagreshvishwakarma6198 5 лет назад

    Sir hook length kaise nikalte hai mere site pe jo chl rha hai aapko batata hu CTL@31.OO5. and COL@ 30.321 to mai hook length nikalta hu CTL-COL-1.05 JO ATA HAI VAHI hai ya kuch aur plz mujhe suggest kro clear cut

  • @mairajhabib9754
    @mairajhabib9754 3 года назад

    Explain relation of Development length at top n Vol A

  • @HarishRajput22
    @HarishRajput22 5 лет назад

    Ventonite ka kyo use karte h

  • @jiajia2976
    @jiajia2976 6 лет назад +1

    Should the TREMIE PIPE be lifted a little bit before every dropdown of concrete from hopper?

    • @SoumenMiddey-hp6uv
      @SoumenMiddey-hp6uv 6 лет назад

      Jia Jia yes tremme pipe should be lifted so that concrete easily dropdown to the bore and treme pipe will be free

    • @jiajia2976
      @jiajia2976 6 лет назад

      Soumen Middey thanx.. if possible kindly share a full video of piling...

  • @veerapathirans2976
    @veerapathirans2976 4 года назад +2

    i seen ur all videos it is all for usefull to us, so please sent me the construction field excavation means starting from upto Ground floor videos i need please sent me in tamil.

  • @SurajKumar-oc3he
    @SurajKumar-oc3he 2 года назад

    Sir pile ko is code ke hisab se kitna dismentel harna chahiye

  • @Shakil_-gg2cy
    @Shakil_-gg2cy 3 года назад +1

    Hopper volume kivabe ber korbo?

  • @kovidprabhakar8522
    @kovidprabhakar8522 3 года назад

    Sir quatity of steel on site piling mei kaise check kru uspe ek video bnao na . I mean i calculated the quantity abhi usko kaise compare kru.

  • @SurajKumar-oc3he
    @SurajKumar-oc3he 3 года назад +1

    Sir hopper ka volume pe video chahiye sir plz help me

  • @siddhunaik9309
    @siddhunaik9309 2 года назад +1

    But how do we know that trimie pipe is inside concrete or not, because we can't see at that depth.

  • @ashutoshgupta9250
    @ashutoshgupta9250 4 года назад

    Sir Jo pipe ke niche space hai woh kaise chodoge hum. Kyuki jab pile bore karte hai woh cylindrical hi jayagi na

  • @saleemabbas9638
    @saleemabbas9638 5 лет назад

    Very Goood

  • @CryptoExpertVikas
    @CryptoExpertVikas 5 лет назад +2

    Development length Kya hota h

    • @success555
      @success555 5 лет назад +1

      Sir
      I am continuous follower of your channel.

    • @success555
      @success555 5 лет назад +1

      A development length can be defined as the amount of reinforcement(bar) length needed to be embedded or projected into the pile cap or column to establish the desired bond strength between the concrete and steel (or any other two types of material).

  • @success555
    @success555 5 лет назад +1

    Really nice and very useful video. Thanks a lot. #Success555

  • @parasnath9016
    @parasnath9016 5 лет назад

    awesome. sir ji

  • @imransayyed2251
    @imransayyed2251 4 года назад

    Watertable high h agar, to tremiepipe thoda bhi upar rakhne se Paani jayga pipe me. Fir concreting kaise hoga?

  • @SanjayPal-pe8iq
    @SanjayPal-pe8iq 6 лет назад

    good work

  • @mosharofhossain9221
    @mosharofhossain9221 6 лет назад

    nice.. I want to more video

  • @krishnak.b5546
    @krishnak.b5546 4 года назад

    Sir tremie pipe termination level se kitna up rkhana hai , ye aapne apne man se bataya ki IS code bhi padha hai, mr L&T

  • @sekharchandradas2960
    @sekharchandradas2960 2 года назад

    Sir pile ka level kaise lete hai ek video banaiye please..

  • @YouTubesamal
    @YouTubesamal 6 лет назад +3

    Can you upload the way to make the BBS of PIER CAP

    • @DJ-nb8bk
      @DJ-nb8bk 4 года назад

      Hai video...Sir ne upload kiya tha

  • @thakurram920
    @thakurram920 2 года назад

    Kaise nikalte h volume Hopper

  • @antuwarule6740
    @antuwarule6740 5 лет назад

    Nice

  • @238nf2
    @238nf2 2 года назад

    Sir hamare piling me pura pani bhar gya tha .mistri ne usi me sukha masala diya kya kare sir

  • @eratishthakur9760
    @eratishthakur9760 2 года назад

    Good evening sir i am very eager to know about you & your profile sir please share with me for this I will always thankful to you sir

  • @TheSiddharth10
    @TheSiddharth10 4 года назад

    SIr , I am working on a test pile cage with 2 m dia. It has transverse reinforcements on top. Can you please explain at what point do we install it in the cage . Since the tremie pipe has a diameter more than the spacing of the transverse reinforcements, we cant put it through it. And we cant remove the tremie pipe to make the transverse reinforcement since extra concrete flushing needs to be done. Please clear this doubt.

    • @elixtido1448
      @elixtido1448 2 года назад

      hmmm. that's a tough one. just eyeball it.

  • @deepakkumarpandey6696
    @deepakkumarpandey6696 3 года назад

    bentonite test kese kiya jata h sir jee

  • @Nasirsajjad164
    @Nasirsajjad164 4 года назад

    Which foundation is best pile or raft???

  • @civilengineer9687
    @civilengineer9687 3 года назад

    Kitna bentonite require hota h???

  • @Ajay_ojha872
    @Ajay_ojha872 6 лет назад

    Ye tuh samjh gye kyu hota , but sir kase implement Karenge....volume furstum nikale ke volume aajaye hopper ka sir can u explain dememsion of trime pipe,. Sir u video always help us...U doing nice job

  • @arindammandal393
    @arindammandal393 4 года назад +1

    Hopper ka volume thora dal dijiye ya to link de dijiye

  • @AmitPandey-pb3sv
    @AmitPandey-pb3sv 3 года назад

    Sir please provide one video for how many bags are bentonite in 30 mtr pile 🙏 we ha requested

  • @priyamroychowdhury1804
    @priyamroychowdhury1804 6 лет назад

    Sir ji volume of Hooper kaise nikalenge dijia aur uska basis kitna length breadth height rakenge trimmie pipe ka niche woh bhi process bol dijia aur last ld kitna rakenge approximately hiath kitna min rakhna Hai as per is code Tora dijia ek compact video ban jyega

  • @sukhangsusekharjena5705
    @sukhangsusekharjena5705 4 года назад +1

    Plz make a vedio regarding deep excavation for raft foundation

  • @sontoshgour134
    @sontoshgour134 6 лет назад

    Nice sir

  • @adityajena6226
    @adityajena6226 6 лет назад

    nice sir aur banaiye civil ke video

  • @subhadippatra7546
    @subhadippatra7546 5 лет назад

    Pile k upper ak full video banaie.. trimme pipe opening ka video banake dijie

  • @MohammadShahid-xn3jd
    @MohammadShahid-xn3jd 3 года назад

    Sir pile ke andar water q bharty hy.

  • @tappu5958
    @tappu5958 6 лет назад

    Mukesh ji thank you

  • @azharkhan1991
    @azharkhan1991 6 лет назад

    Kya aap tender filling aur quotation submission video upload kar sakte hai

  • @jagabandhubehera2695
    @jagabandhubehera2695 6 лет назад

    Sir kitna depth tak pile head cutting kartehn ?

    • @SoumenMiddey-hp6uv
      @SoumenMiddey-hp6uv 6 лет назад

      Jagabandhu Behera it will mentioned in construction drawing

  • @sheikhkais4140
    @sheikhkais4140 6 лет назад

    Good

  • @hackingboredpile4887
    @hackingboredpile4887 3 года назад +1

    👍👍

  • @jayantsingh7437
    @jayantsingh7437 3 года назад +1

    What is cutoff level....?

    • @LearningCivilTechnology
      @LearningCivilTechnology  3 года назад

      Video bana dunga ispe jald

    • @jayantsingh7437
      @jayantsingh7437 3 года назад

      @@LearningCivilTechnology please.......kahin nhi mil rha.......poora smjh bhi nhi aa rha shi se
      Hope video jald aayegi

  • @370n9
    @370n9 5 лет назад

    Tq Bro...

  • @kumarravi4907
    @kumarravi4907 3 года назад

    Sir pile ka bbs bataye. Pile 30 m and dia 1200

  • @akashmetre8899
    @akashmetre8899 5 лет назад

    hopper volume kaisa nikalna hai sir

  • @sarimkhan6640
    @sarimkhan6640 6 лет назад

    sir hopper k size kuch fix hota hai ya different sizes me available ho jaate hai
    or plz make a video to how to find the volume

  • @ankitsingh-hg4cm
    @ankitsingh-hg4cm 6 лет назад +1

    sir,how to find hopper volume and reinforcement requirement

    • @Benlee753
      @Benlee753 5 лет назад +2

      Bore depth-Cone+lap =reinforcement length eg: depth=10m, lap=50 cm, Chisel Cone=30cm =10.50m-.30=
      10.20 m Reinforcement length..

  • @sinhaanajagatap9393
    @sinhaanajagatap9393 4 года назад +1

    How to cast pile when water table is to high....is it any tech to remove water before casting pile

  • @vipulsingh8647
    @vipulsingh8647 6 лет назад

    सर बैडोनाइट क्या है

  • @yashgupta6826
    @yashgupta6826 6 лет назад

    Thank You Sir..........

  • @tariquesiddiquitariquesiddiqui
    @tariquesiddiquitariquesiddiqui 6 лет назад

    Why provide bentonite before casting... And what will be the duration of of bentonite...

    • @sarimkhan6640
      @sarimkhan6640 6 лет назад +1

      Bentonite is used for the stability of soil under pile so that soil can not fall or mix with the concrete while pouring

    • @tariquesiddiquitariquesiddiqui
      @tariquesiddiquitariquesiddiqui 6 лет назад

      @@sarimkhan6640 thanks dear... Can you tell me about timing duration please...

  • @ramakantbhatt6798
    @ramakantbhatt6798 3 года назад

    Sir very nice vedio.Alots of thank.
    But I wanted to know one thing that why the LD is said as development length when D comes first and L has comes last.

  • @Yogendrasingh-yx2hu
    @Yogendrasingh-yx2hu 6 лет назад

    Sir bentonite clay kyu dalte hai

    • @Benlee753
      @Benlee753 5 лет назад

      Commonly Kidhar strata sand athey hi udhar Bentonite use karthe hi nahi tho bore ko cave in ayegaa...

  • @engineer-0007
    @engineer-0007 3 года назад

    Agar cc cutoff level tak he bhare

  • @VAIBHAVSPAL
    @VAIBHAVSPAL 6 лет назад

    Thank you sir

    • @mohankrishna3965
      @mohankrishna3965 6 лет назад

      If the total depth of the is 27.26 meter. How much of the gap b/w the pile bottom.

  • @AmitKumar-vb5bz
    @AmitKumar-vb5bz 6 лет назад

    Sir ye kaha se bata rahe ho aap ,ye kha likha hai, IS Codes ki videos lekar ao..

    • @Sujeet1919
      @Sujeet1919 4 года назад

      Bhai , practical Hain ,

  • @shaileshbhoi7272
    @shaileshbhoi7272 6 лет назад

    Survey r.l ,tbm nikalna bataye

  • @southindiahindidubbedmovie8221
    @southindiahindidubbedmovie8221 5 лет назад

    Cut level calculation karia sir.with drawing.

  • @rahulmaurya2257
    @rahulmaurya2257 6 лет назад +2

    Sir hopper ka volume kaise nikalenge

    • @trivijaytiwari6214
      @trivijaytiwari6214 5 лет назад

      ruclips.net/video/e6WmvCZkhdY/видео.html es link pr click kr Dekh lo aap

  • @dipakpakrasi5995
    @dipakpakrasi5995 3 года назад

    👍👍👍👍👍

  • @subhankarbiswas3045
    @subhankarbiswas3045 6 лет назад

    Sir, app coarse aggregate nd fine aggregate combined graduation calculations ke uper ak video banaiye...please bohut help hoga

  • @j.psingh4034
    @j.psingh4034 6 лет назад

    Please pile casting process video share

  • @ronisarkar8543
    @ronisarkar8543 6 лет назад

    how to calculate tha hopper volume?