Customer Called And Said the Blower Won’t Shut Off!

Поделиться
HTML-код
  • Опубликовано: 27 сен 2023
  • In this video I visit a mobile home, the tenants said they can’t turn off the blower! #hvacguy #hvaclife #hvac #airconditioner #heatpump #hvactechnician #furnace #hvactrainingvideos #hvacinstall #hvacinstall #mobilehome
    Merch Store : hvac-guy-2.creator-spring.com
    HVAC LIFE FB Group: / 521086622906115
    Here are links to the tools I use, And it costs you nothing extra to buy from this list:
    Inficon D-Tek Stratus: amzn.to/3RvnXOl
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Blutooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
    Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
    Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    Makita XDT16: amzn.to/3riXuaJ
    Makita 18V Light: amzn.to/3Fw4GW4
    Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
    Makita Jobsite Radio: amzn.to/3HuVp2u
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Flag Velcro Patch Kit: amzn.to/3K8Eswx
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Fluke 975 Air Meter: amzn.to/3GwD9oM
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Aims Power Inverter: amzn.to/3qOSc87
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    American Flag Gator : amzn.to/3rKBl5u
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Комментарии • 52

  • @tphvac87
    @tphvac87 10 месяцев назад +11

    Omg that filter is epic!!! Change your filters people!!

  • @danobrien3109
    @danobrien3109 10 месяцев назад +20

    Most units will go to continuous fan when an open limit or roll out occur. This is a built in safety in a lot of control modules.👍👍🇨🇦

  • @paulmoffat9306
    @paulmoffat9306 10 месяцев назад +8

    Relays can 'weld' their contacts, after enough actuations - each open/close has a small arc that pits the contact surface over time.

  • @larryl2459
    @larryl2459 10 месяцев назад +7

    First 2 minutes I noticed they are going to have more than fan troubles.

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 10 месяцев назад +14

    Good video. You’re are really good at electrical troubleshooting

    • @HVACGUY
      @HVACGUY  10 месяцев назад +5

      Thanks 👍

  • @kens.3729
    @kens.3729 10 месяцев назад +4

    Thanks Curtis! Hello 👋 Riley! 👍🙏

  • @user-rq8ch3xb2j
    @user-rq8ch3xb2j 10 месяцев назад +4

    You are the best down south Curtis…
    Rick from
    United Americas Plumbing • HVAC.
    🇺🇸🤜🤛🇺🇸

    • @HVACGUY
      @HVACGUY  10 месяцев назад +2

      Thanks

  • @billybrown1979
    @billybrown1979 10 месяцев назад +3

    that was a quick fix good work. be safe.

  • @jazziez6467
    @jazziez6467 6 месяцев назад +3

    my blower was stuck on and for the $100 service call the guy pushed the reset(red) button in on limit or rollout switch hiden below the burners, $100 then left without even putting it back together, I had it spotless when he arrived and would never have such filth on my doors, filter, or inner furnace, never

  • @markspott1741
    @markspott1741 4 месяца назад +1

    Excellent video of troubleshooting the blower. Probably saved another call by changing out the air filter too!

  • @treyconner1991
    @treyconner1991 10 месяцев назад +2

    You can never have to many flashlights. 🤙🏻

  • @robalexander7348
    @robalexander7348 10 месяцев назад +3

    A nice fix Curtis, and so good to see a new clean filter change 👍 Au

    • @HVACGUY
      @HVACGUY  10 месяцев назад +1

      Thanks 👍

  • @Tito-hvac8
    @Tito-hvac8 10 месяцев назад +3

    Great job. You make it looks easy but it’s not. It takes time to get there👍

  • @carlsmith5919
    @carlsmith5919 10 месяцев назад +3

    I was starting to wonder when you were going to lay down so you can reach that screw. I hate those units, they have so limited hand space behind the line set. I worked one a while back, where someone replace both relays😮😮 with contacts, in that small space.

  • @sjadev
    @sjadev 9 месяцев назад

    I always appreciate how thorough you are Curtis

  • @bamatractor
    @bamatractor 10 месяцев назад +3

    I had a brand new blower control board stuck on a few days ago.

  • @stevencossaboon3237
    @stevencossaboon3237 10 месяцев назад +2

    Nice work Curtis.

  • @Capt-Intrepid
    @Capt-Intrepid 10 месяцев назад +12

    I had a defective POS Nest thermostat that would turn the blower on but not the compressor. Now using a ecobee thermostat that understands I am the master. Don't buy Nest.

    • @caru3257
      @caru3257 10 месяцев назад +6

      Can I get an Amen?

    • @jhatfield2755
      @jhatfield2755 10 месяцев назад

      Dont buy a nest or a ecobee lo

  • @johnnym.rodriguezr3562
    @johnnym.rodriguezr3562 10 месяцев назад

    Great job diagnosing!

  • @frankblankenship3026
    @frankblankenship3026 10 месяцев назад

    Very informative thanks

  • @odc43054
    @odc43054 10 месяцев назад +3

    I had an ECM fan motor on a 10 year old Payne package unit that would continue to run even with the control wiring removed. Motor had to be replaced. Bad electronic brain.

  • @CommercialGasEngineerVideos
    @CommercialGasEngineerVideos 10 месяцев назад +2

    Another good video

  • @sergiohernandez4163
    @sergiohernandez4163 10 месяцев назад +1

    Them mobile home units sequencers always confuse me lol. I'm just a beginner on working on mobile home furnace

  • @woodystokes1543
    @woodystokes1543 10 месяцев назад +3

    Nice work 😊

    • @HVACGUY
      @HVACGUY  10 месяцев назад +3

      Thanks 😄

    • @woodystokes1543
      @woodystokes1543 10 месяцев назад +2

      @@HVACGUY you’re welcome
      I hate that they run he line set in front of the control panel.

    • @bobboscarato1313
      @bobboscarato1313 10 месяцев назад +2

      @@woodystokes1543 Pretty poor design for downflow heater; however on the right side they have plenty of room to run the refrigerant line set and the drain line!

  • @harrydickson4575
    @harrydickson4575 10 месяцев назад +4

    👍👍👍

  • @RossTheGenMan
    @RossTheGenMan 10 месяцев назад +2

    Nice work and Explanation. Not sure if there was a filter in the door before you started?

    • @HVACGUY
      @HVACGUY  10 месяцев назад +2

      No there wasn’t

  • @mos8541
    @mos8541 10 месяцев назад +3

    the oooole 9340...

  • @fernandobazan829
    @fernandobazan829 10 месяцев назад +3

    Can’t see what your explaining with those wires i guess camera angle is off what controls that relay? The thermostat or the pcb?

    • @HVACGUY
      @HVACGUY  10 месяцев назад +3

      Thermostat

    • @fernandobazan829
      @fernandobazan829 10 месяцев назад +2

      so basically the thermostat send a call 24 V two the sequencer the sequencer send the 24 V to that peanut relay to turn the fan on. Also the thermostat could send 24 V to turn on the air conditioning and also turn on the fan from that same relay, so if that relays stock the fan to beyond all the time, no matter what good job

    • @user-su5ft8lc9q
      @user-su5ft8lc9q 10 месяцев назад +1

      Dr Curtis is on the job he fixes ot the first time. Unlike Medical Doctors that just keep you coming back to run up your bill.
      Lawyers, Doctors, and Weathermen, should be paid on whether the do the job right the first time. Most every other profession gets paid only if they fix it right the first time. That's why they all it a practice, and want paid any way.

  • @GodisAgapelove4172
    @GodisAgapelove4172 8 месяцев назад

    If this doesn’t get fixed will it cause an increase in my electric bill?

  • @bendimaculangan2236
    @bendimaculangan2236 10 месяцев назад

    Can u recommend an honest tech right here in pinellas county, Florida?

  • @steveurbach3093
    @steveurbach3093 10 месяцев назад +5

    What is with the seriously dirty filters?

  • @karellodewijks4971
    @karellodewijks4971 10 месяцев назад +2

    😊😊👍👍

  • @jamierushing
    @jamierushing 10 месяцев назад +2

    Hi bro from west Alabama

    • @HVACGUY
      @HVACGUY  10 месяцев назад +1

      What’s up man

    • @jamierushing
      @jamierushing 10 месяцев назад +2

      @@HVACGUY nothing much

  • @fernandobazan829
    @fernandobazan829 10 месяцев назад +3

    One more quick question what are you calling a sequencer?

    • @fernandobazan829
      @fernandobazan829 10 месяцев назад +3

      never mind I looked it up I call it a heat relay thanks anyway ur a smart tech

    • @bobboscarato1313
      @bobboscarato1313 10 месяцев назад +5

      It brings in one heat strip at a time the reduce power surge!

  • @kylemason5951
    @kylemason5951 10 месяцев назад

    Could be the blower module or relay