180 m के बंडल की pvc coating 90m वाली से पतली होती है । कंडक्टर यानि copper wire भी 90 m के मुक़ाबले कम तारों से बनी होती है । घर आप ऐक ही बार बनाते हैं तो 1.5 mmऔर 2.5 mm की तार ही प्रयोग करे। । 0.5 या 0.75 mm का प्रयोग घर में न करें
If you see inscriptions on Modular switches being used rampantly , they are recommending 1.5 Sq mm for 6A switch or socket and 2.5 Sq mm for 16 A switch socket . Next time take a good look at your purchase .
Hello bhai,, Muje 400 meter durr service wire lagana hai main pole se,, khet mein lagana hai,, toh muje kitni sq mm ka wire lagana hoga,, or voltage or current kitni loss hoga..??,,
Mcb type nahin bataya aapne its very important Earth fault elcb install nahi kiya isko earthing nahin karana hai Electrical safety building protection pankha short hone par pura building mai power running hoga ye sab cibil engineer ghanta pata hai
Bhai mene apna ghar men jo Mcb box se wire aya hai 2.5 mm ka wire diya hai baat me mene looping karke dushre room ko Neutral 2.5 or phase 1.5 ka diya hai. Koi problem to nahi hogi na. pls 🙏 bhai help me 😢❤
हमारे घर के अंदर अर्थ वायर 1.5mm और फेस वायर 1mmकाम में लिया है इलेक्ट्रीशियन ने तो क्या यह ठीक है क्या ??अर्थ और फेज दोनों वायर बराबर एमएम की होनी चाहिए??
अगर 2.5 एमएम की वायर है कितना दूर तक ले जाएं 1 तन की वह एक चले और आप जो थोड़ा कुछ और कन्फ्यूजन वाला बता रहे हो अरे देर पर भी फ्री चलता भाई एक 1 तन की देर की वायर कभी चेक करो लगाकर उसका लोड माफ करो मशीन से देखो फिर उसमें कोई तकलीफ पड़ता है कि नहीं डेट पर भी चलता है ऐसी मैं ही काम ही करता हूं मेरा एक्सपीरियंस से आप चेक
Idiot electrician should have Original Electrician Licence. Also majority of electrician are from up, bihari not be relied on unless & untill You have good qualified licenced Electrical Supervisor
Sar Aap Ji ne bahut hi achhi jankari Diya hai dhanbad Bahadur Singh sidhu
Asli mudda 6:22 se
Thank you sir aapka video help full rha
Good informetion
Thanks so much sir very helpful vedio
👍👍👍👍👍👏👏👏 super exploration
Good picture good idea
Very informative and interesting and helpful video.
nice ❤
Nice bro
0.75 sq mm - 5 amp
1.00 sq mm - 8 amp
1.50 sq mm - 11 amp
2.50 sq mm - 18 amp
4.00 sq mm - 25 amp
6.00 sq mm - 33 amp
10.00 sq mm - 50 amp
In Open, Concealed ?
@@zlr9449 for concealed and for casing wiring the amp rating increase 1 to 2 points
Ok sir
Ankr k
Good information 😊
180 m के बंडल की pvc coating 90m वाली से पतली होती है । कंडक्टर यानि copper wire भी 90 m के मुक़ाबले कम तारों से बनी होती है । घर आप ऐक ही बार बनाते हैं तो 1.5 mmऔर 2.5 mm की तार ही प्रयोग करे। । 0.5 या 0.75 mm का प्रयोग घर में न करें
Nice video 👍👍
❤ Super 👍
Thank you sir
Good
Good 👍👍👍👍👍👍
Very good
Thanks for tips 👍🎉
Thanks
Very nice
Jay shree Ram sir Dhanyawad
❤❤❤
❤
Sir kon si comp ki wire teek rahgi kon si company ki mcb Best rahegi iske bare mein video banye
If you see inscriptions on Modular switches being used rampantly , they are recommending 1.5 Sq mm for 6A switch or socket and 2.5 Sq mm for 16 A switch socket . Next time take a good look at your purchase .
Can i attach 10 aph mcb with 1.5 mm supply wair?...minimal load
🙏🙏
2.5 sq mm wire ki load capacity 3500 watt ki hoti hai ... Aram se 2500 watt ke appliances chala skte hain...
Sir agar hum apne room me 10 ampere ki MCB laga le heater ke liye, aur main board me 3 ampere ki MCB lagi hai to 3 ampere wali MCB gire gi to nahi??
Mene greatwhite naam ka pipe
Use Kiya hai
Sir, kya hum 6sq mm wire sabhi prakar ke liye fan,ac,freez, gizer ke liye use ker sakte hai
Paisa jyda ho toh 10mm ka bhi use kar sakte hain 👍
1.5 mm wire ke badle 0.75 mm wire double use kar sakte?
Hlo , 1 room me 2 bulb ,1 fan ,1 fridge he .. esme kitna ampair ka mcb used garna chahiye kohi help kardige ..
Sir hm new iti kr ke aya hu hm ko kuchh pta nhi hai video ke madhayam se bataye kuchh kuchh krne ka
Hello bhai,,
Muje 400 meter durr service wire lagana hai main pole se,, khet mein lagana hai,, toh muje kitni sq mm ka wire lagana hoga,, or voltage or current kitni loss hoga..??,,
Sir 2.5 mm ke virgin se cooler fan freez fan ..to chal sakta hai na... please sir reply me
4 kw connection ke liye main wire 6 sq mm ka use kar skte hain?
Wire ampacity depends on the voltage and the length of wire
Gurugi geene ka videos dalo sariya ( bhadne ) ka
Havells aur Anchor
1.0 mm का प्रयोग कर लें । दोनों को लिए वैसे भी २०-२५ मीटर से ज़्यादा तो लगेगा ही नहीं ।
Havells is best
Haveles. Finolex
Rr cabel use kar sakta ha
House wiring me Inverter me kitne mm ka Wire use kr sakte hain please Reply
Me khatin compnny ka use kr rhanhu
Apne board kis company ka use kiye h name batao
6 amp mcb me 2.5 mm ki lag sakte hai
Paramount wire
Do horse power motor chalane ke liye kitne mm tar ki jarurat hoti hai
Sir 1.5 mm wayer me 1fen or 100watt ka 4buluf lupig kar sakte he sir btaye sir
Haa
Helo bhai koi electrician ka kaam karta hai
Ye jaankari aur pahle Mili hoti to mere Ghar ki wiring sahi hoti
Naye electrician ko na pakde yo naya electrician kaha jayega fir
1:5 firij aur motar 15 hpi ke chala sakta hu
RR Wire
Mcb type nahin bataya aapne its very important Earth fault elcb install nahi kiya isko earthing nahin karana hai
Electrical safety building protection pankha short hone par pura building mai power running hoga ye sab cibil engineer ghanta pata hai
Sir ek room mein 4 board hai Induction, Fridge, Grinder aur purify to kitna circuit banaye???
2 circuit. 1.5 mm red for light. and 2.5 mm red for socket and 2.5 mm black for common neutral And .75 mm for ground.
For light 1.5 sq mm and for these three heavy load use 4 sq mm wire and neutral 4 sq mm and earthing 1.5sq mm
Location kah par ha shope
Power= curret×voltage
Apar aparshakti
4mm
Bhai mene apna ghar men jo Mcb box se wire aya hai 2.5 mm ka wire diya hai baat me mene looping karke dushre room ko Neutral 2.5 or phase 1.5 ka diya hai. Koi problem to nahi hogi na. pls 🙏 bhai help me 😢❤
Nooo
@@Sadrees-qq7ie why
Mera 0.75mm wire par 1000 watt load chalta hai 8 sal se abhi tak kuch nahi hua
Yamraj 10 sal Tak wait karte hain😂
Use 1.5 sq mm
@@shashirana9601 😂😂
@@ArunavaPramanik-cl7bw now I used 1.5 mm
हमारे घर के अंदर अर्थ वायर 1.5mm और फेस वायर 1mmकाम में लिया है इलेक्ट्रीशियन ने तो क्या यह ठीक है क्या ??अर्थ और फेज दोनों वायर बराबर एमएम की होनी चाहिए??
लोड के हिसाब से
Mai 1.5mm use karta hun
R.R water
Rr kable wire
Inverter line connection ke liye kaun sa wire size lagayega?
1.5mm
Sir 2.5 mm wire par kitna mcb laga sakte hain
16 amp
Mera Electrician 6mm ka bhi bol raha hai lagane ko
इसकी कोई पी डी एफ हो तो भेजने की कृपा करें।
Db derasig me phele MCB lagatey hi ya diryesg kartye hi aap ne to ulta kar diya
1 ton AC me 2.5 wire use kr sakte he kya sir
Ha bilkul 👍
Kar sakte bhai
S
1.5 sq mm mein chal jayega
किमत क्या है
अगर 2.5 एमएम की वायर है कितना दूर तक ले जाएं 1 तन की वह एक चले और आप जो थोड़ा कुछ और कन्फ्यूजन वाला बता रहे हो अरे देर पर भी फ्री चलता भाई एक 1 तन की देर की वायर कभी चेक करो लगाकर उसका लोड माफ करो मशीन से देखो फिर उसमें कोई तकलीफ पड़ता है कि नहीं डेट पर भी चलता है ऐसी मैं ही काम ही करता हूं मेरा एक्सपीरियंस से आप चेक
300v ka carrent he 220 v ka kese kare mera to leptop kharab ho gaya he
Use staiplizer
Use 90V - 300V stabilizer v guard
Kisi ghar me 6 mm wyar lagti hi
Sir 1.5 mm wire par kitna watt ka load dal sakte hai
1500 watt
2000 watt tak
sir kya hum 1 kamra jisme 3 bulb or 1 fan lagana hai toh usmein 1.5 mm phase or 1 mm neutral wire ka use kar sakte hai
Ha belkul लगा सकते हो
1:42
Yes
Ha bhai बिलकुल
Not for better future only use all circuit 1.5 mm red black with .75 ground.
First of all confirm that wire size and load capacity, don't misguide.after that make video😂
Which wire company is best for house wiring top brand quality?
Bhai aapka information rong hai please wire carrying capacity ka perfect information dijiye.
Standard, Havells, polycab
Fybros
Rrrr
Sab galti bata raha hai
Kaam ka baat Karo yar
Kya bakwas kar raha hei
WRONG INFORMATION
Idiot electrician should have Original Electrician Licence.
Also majority of electrician are from up, bihari not be relied on unless & untill You have good qualified licenced Electrical Supervisor
Time wastage video
0.75ka wire ko kaise neutral phase kaise use kar sakte h batao
Mere yaha klick ka laga hai 2.5 mm sahi hai company
Klich is local company
سر آپ نے بالکل مشکل ویڈیو بنائی ھے۔ آسان کر دیتے
❤❤❤