Installing A VXT-24 & Fixing A Leaking Steel Wet Return

Поделиться
HTML-код
  • Опубликовано: 9 фев 2025
  • We piped in a VXT-24 using the Kendorf / SuperStrut fixture and a combination of IP (iron pipe threads), ProPress and sweat fittings and valves.
    We had a leak on the new brass fittings.
    We used a MegaPress fitting to replace a partly clogged & failing section of steel wet return.
    The old threaded steel end of the wet return likely failed & clogged due to galvanic corrosion when copper was tied in to the steel 20+ years ago.
    We set the return up so a that "no return" flush could be done while water is added to the boiler.
    Removing that old oil tank sure freed up a lot of real-estate!

Комментарии • 4

  • @lolMyke
    @lolMyke 5 месяцев назад +3

    Excellent installation Gordon. I really enjoy your videos. Thanks.

  • @dannywilkins887
    @dannywilkins887 5 месяцев назад +1

    At the risk of sounding boring , another excellent install, do you have to register the boiler for warranty purposes with the manufacturer?

    • @gordonschweizer5154
      @gordonschweizer5154  5 месяцев назад

      Thank you, sir.
      Not with this particular boiler manufacturer, as far as warranty registration goes.
      We get this boiler delivered to the job site directly from the local stocking representative, so they have the warranty already "baked in" to their system, so to speak.