ประกอบ Gear Coupling Steam Turbine

Поделиться
HTML-код
  • Опубликовано: 29 окт 2024

Комментарии • 22

  • @allanstacruz-pp3ye
    @allanstacruz-pp3ye Год назад +1

    next time, remove the key shafting, the coupling gear is wrongly placed, the gear tooth is a small part in the back, last place the key after the gear enters

  • @mohammedalsaedi6257
    @mohammedalsaedi6257 3 года назад +2

    The problem is that the team did not heat the hub properly. Please check the heat value I think it is around 450º F (232º C)

  • @diogenessalazar2758
    @diogenessalazar2758 2 года назад

    1 Debieron utilizar los instrumentos de medición y asegurarse de que la abertura fuera uniforme
    2 Aplicar anti seize en todo el eje y chaveta
    3 asegurarse de que la chaveta pasara deslizante en el canal del acople
    4 Usar calentador por inducción o aplicar fuego directo
    5 La operación debe ser mas rápida y segura
    6 Al parecer el engranaje se coloco en dirección contraria
    Saludos!

  • @KamiCrit
    @KamiCrit 6 лет назад +1

    Hope those bearings inside are ok.

  • @trilochandas8016
    @trilochandas8016 4 года назад +1

    If you team maintain the hub temperature and use the heavy hammer from starting it was easy to fix

  • @tapanpradhan1993
    @tapanpradhan1993 2 года назад +1

    Coupling need to more heat. If there is proper heating at least 200°© for 2 hour coupling not need to beat. Only in push fit it will insert.

    • @ตระกูลภาสว่าง
      @ตระกูลภาสว่าง  2 года назад

      Yes, I am correct, thank you.

    • @hassanm2357
      @hassanm2357 Год назад

      Ambient temp + 80 degrees C should be enough and max 120 C ..
      Possibly they didn't heat evenly or didn't clean the bore .
      Based on this video , i would expect anything from them .
      In the end of they day , they think that the "job is done" as they have installed the coupling hub no matter how was that performed .. lmao

  • @BrunoooooSantos
    @BrunoooooSantos 7 месяцев назад

    Como NÃO montar um acoplamento.
    Começando pelos EPIS, que não utilizam.

  • @zubairanjum3087
    @zubairanjum3087 5 лет назад +1

    Which company this steem turbain?

  • @Prakash-lw4nc
    @Prakash-lw4nc 7 лет назад +1

    What r u doing..? More time taken.....

  • @Prakash-lw4nc
    @Prakash-lw4nc 7 лет назад +3

    Very wrong procedure

  • @mohammadhussain6583
    @mohammadhussain6583 2 года назад +1

    I think that coupling fixed in wrong direction 🙄

    • @tapanpradhan1993
      @tapanpradhan1993 Год назад

      U r right. The wider part should be outside.

    • @MA-pt6nz
      @MA-pt6nz Год назад

      @@tapanpradhan1993 So all these guys do not know what they are doing? And you know? You are very wrong. The direction is absolutely 100% correct. Check the drawing for this type of coupling.

    • @chethankumar4498
      @chethankumar4498 8 месяцев назад

      ​.. Correct.... I think the preparation went wrong... They should pre clean the shaft and lubricated.

  • @jayangeles210
    @jayangeles210 6 лет назад +1

    No preparation. And no safety. Barehanded holding the wood. Next time atleast do it properly.

  • @hassanm2357
    @hassanm2357 Год назад

    Hahahahahahahaha ..

  • @johandelange3960
    @johandelange3960 Год назад

    Nope no good 😂😂