Electrical Current (Amperage) Basics

Поделиться
HTML-код
  • Опубликовано: 10 июн 2024
  • Bryan teaches the Kalos apprentices about electrical current (amperage). He covers some basic electrical theory and troubleshooting practices that may require you to measure amperage in the field.
    Current, not to be confused with “power,” refers to the movement of electrons in an electrical circuit. Electrons don’t “flow” through a circuit like water through pipes, but they behave more like little forcefields, which is what does the work and is picked up by the amp clamp of a multimeter or ammeter.
    Voltage, on the other hand, is like a source of electrical pressure. The more voltage behind a current, the stronger the field. There needs to be electron motion for there to be current; voltage doesn’t necessarily indicate the presence of current.
    Voltage and current make up Ohm’s law, which states that voltage is equal to the multiplication of current and resistance. In other words, current increases as resistance decreases and vice versa.
    If you’re verifying that a system is off, you’ll clearly want to measure voltage with the equipment off; however, you’ll want to measure voltage under load if you’re checking equipment operation.
    If you’re working on a conductor and notice that the current is higher than it’s supposed to be with normal voltage, then the resistance is low. That could happen because the windings or conductors touch another surface and make an undesigned path. We call those situations “shorts.” To make this concept easier to understand, Bryan uses a traffic analogy; a highway with potholes will make it harder for cars to pass through, but an exit that allows traffic to bypass the slower path on a superhighway and move a lot more cars. That superhighway behaves like a short. High amperage should cause breakers to trip or fuses to blow.
    In the case of a thermostat, the R terminal has a path in, Y has a path out, and there is a contactor coil. Then, that contactor coil connects back to C, common. When the contacts close, current may flow; your amp clamp should read roughly the same amperage at all points on the conductor. Contactors that don’t pull in properly could draw higher current than normal. Also, the amperage along the conductor should match the current inside the thermostat; the temperature could rise if another component of the low-voltage circuit is drawing higher current than normal. So, a failed thermostat could be caused by higher current elsewhere in the circuit,
    To get a proper amperage measurement, you will want to make sure you center it inside the amp clamp. If the conductor is too close to the edge of the jaws, you could read a higher amperage than what’s really there.
    Read all the tech tips, take the quizzes, and find our handy calculators at www.hvacrschool.com/.

Комментарии • 21

  • @YaTuSabe7809
    @YaTuSabe7809 Год назад +6

    Thank you Brian! I appreciate what you are for me and techs alike. I will try my bed best to make it ti the next symposium.

  • @ciciedee5474
    @ciciedee5474 Год назад +2

    I prefer Shazam or Gee Golly. I have been in classes since 1978. You are by far the best teacher I've ever seen. Please never show memes in class

  • @bikerbobcat
    @bikerbobcat Год назад +1

    You know a video is good when they ask a question and I reflexively answer it here, in my living room, days later.

  • @Hopefullymarried
    @Hopefullymarried Год назад

    Wow! This helped me immensely. Electrical is NOT my forte. I struggled thru class and now that I’m in the field I’m having a struggle still but getting better. This was very easy to understand. Thank you

  • @ccthepope
    @ccthepope Год назад +2

    Bryan, Thanks now I have had that song stuck in my head! "there is power power wonder working power in the blood..."

  • @richarddomasig514
    @richarddomasig514 Год назад +3

    Nice. Bryan is really teaching by "parallelism" to better understand the topic..☺️ Thanks!

  • @realSamAndrew
    @realSamAndrew Год назад +6

    Correction: watts is not work. It's the rate of work. Watt-hours is work.

  • @sameerpremlall8124
    @sameerpremlall8124 Год назад +2

    Thank you for your content. Much appreciated

  • @jasonlozano1810
    @jasonlozano1810 Год назад

    Looking fit Bryan. Solid work🎉

  • @dannyl2598
    @dannyl2598 Год назад +1

    Thanks
    I would like to add that when you are measuring low amperage, it is handy to loop the wire several times and then divide the reading by the number of loops. You can make your own 10 turn loop and put a male spade connector on one end and a female on the other. Some old cliparownd meters came with loops the you could plug in to the Wall outlet and plug you small appliance in to it. I hope this helps someone out.

  • @BrianThomas
    @BrianThomas Год назад

    Wonder working power. I know that song and I agree. It's a great song. 0:12

  • @mikechiodetti4482
    @mikechiodetti4482 Год назад +2

    Basics. Basics.

  • @markhonea2461
    @markhonea2461 Год назад +10

    I am the only person in our shop with an amp probe on my meter. I really don't get it. Use it all the time.

    • @Dashchaser
      @Dashchaser Год назад +4

      Very good explanation and sense of humor 👏

    • @awut13
      @awut13 Год назад +3

      Beer can cold right?

    • @josephcastro9549
      @josephcastro9549 Год назад +2

      Lol I suppose you can guess a compressor has LRA and just replace.

  • @waynegram8907
    @waynegram8907 9 месяцев назад

    HVAC SCHOOL, why would a locked stuck Contactor cause High Current?

  • @Freonleon
    @Freonleon Год назад +2

    From hvac to cutting glass 😂 😉

    • @HVACS
      @HVACS  Год назад

      Side hustle

  • @f.villanueva
    @f.villanueva Год назад

    🥰🥰🥰

  • @nuevopactonola1134
    @nuevopactonola1134 Год назад +1

    Not so cocky in electrical