ZAMIL PACKAGE AC FULL WIRING l PRACTICAL VIDEO (very important) l package AC wiring

Поделиться
HTML-код
  • Опубликовано: 17 ноя 2024

Комментарии • 122

  • @shakib_pathaan555
    @shakib_pathaan555 Месяц назад +1

    Jaise aap video me samjate h bahut hi kaamal ka video lagta bahut kuch sekhne ko milta h

  • @shahidqadri357
    @shahidqadri357 Год назад +2

    Bahut hi achhi jankari di hai apne, shukriya

  • @taufiqkhan3018
    @taufiqkhan3018 3 месяца назад +1

    bhai ap video me bhot accha samjhte hai

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  3 месяца назад +1

      Alhamdulillah rabb al alamin 🤲🤲
      & shukran for liking my video bro 👍

  • @asamad4968
    @asamad4968 Год назад +3

    my Bangladesh se ho🇧🇩 very clear explanation
    thank you so much sir ❤

  • @bilalkazi1886
    @bilalkazi1886 6 месяцев назад +2

    Compressor contrecter over load ki wairing ki vedeo banaw

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  6 месяцев назад +1

      ruclips.net/user/shortsPrWSO_MXedw?si=g04IgY1jrRZhexjl
      ruclips.net/video/NlLcFT5iphc/видео.htmlsi=jOjOeq6eC4PLB4K2
      Aap jab tak ye video dekho
      Main insa allah video banayege

  • @shaonbillal7936
    @shaonbillal7936 Год назад +2

    Thank you vary helpful & informatic video

  • @mofaizanansari1813
    @mofaizanansari1813 9 месяцев назад +1

    Best of luck bhai

  • @creativemind323
    @creativemind323 Год назад +3

    Great sir ji 👍❤❤

  • @janibashamolla
    @janibashamolla Год назад +1

    Good explanation

  • @mohammedaziz6623
    @mohammedaziz6623 11 месяцев назад +1

    Good explain bhai

  • @mdshamsuljoha1171
    @mdshamsuljoha1171 Год назад +1

    Sukriya sir jes❤

  • @adilansari002
    @adilansari002 Год назад +1

    Ek number bhaijaan love u

  • @muhammadnaeem4834
    @muhammadnaeem4834 Год назад +1

    Nice

  • @mohammedtanveer6148
    @mohammedtanveer6148 11 месяцев назад +1

    Very nice

  • @amedhossain6032
    @amedhossain6032 Год назад

    Very nice explained..

  • @airdefence1543
    @airdefence1543 11 месяцев назад +1

    Nice video ❤

  • @TabrezAlam-lw2zl
    @TabrezAlam-lw2zl Год назад +1

    Masha Allah bhaijaan ❤❤❤❤

  • @ashokrawat9081
    @ashokrawat9081 Год назад +2

    Great job Sir ji 👍

  • @tamimsohel3125
    @tamimsohel3125 Год назад +1

    Nice Brother

  • @TATABIRLA0001
    @TATABIRLA0001 Год назад +1

    Thank you so much very clear explain ❤

  • @NoorAlam-k4h4d
    @NoorAlam-k4h4d 8 месяцев назад +1

    اسلام علیکم ۔مھربانی

  • @Jaffarraza12
    @Jaffarraza12 2 месяца назад +1

    Assalamualaikum apki ye video boht achi hai , brother 1 request hai plz kisi bhi packeg unit ko le k video bna dien k bnda wiring diagram sath mn rekh k kesy tracing kry 1 ,1 cheez but control wiring diagram k sath to so that wiring diagram perhna seekh skien video ko dekh k

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Месяц назад +1

      Walaikum Salam wr wb bhai
      OK jnab 👍 & thanks for liking my video bro

  • @HVACAMJADTROUBLESHOOT
    @HVACAMJADTROUBLESHOOT  Год назад +1

    face book group name
    for HVAC knowledge 📚
    AC TECHNICIAN GULF
    facebook.com/groups/134091166017387/?ref=share

  • @MdShahid-tt8rd
    @MdShahid-tt8rd Год назад +1

    Thanks brother 👍

  • @VinuKumar-n2u
    @VinuKumar-n2u 9 месяцев назад +1

    Hii make one video zamil slave board how is chang setting

  • @ArmanAli-ts4is
    @ArmanAli-ts4is 3 месяца назад +1

    ❤❤❤

  • @ehrajkhan57702
    @ehrajkhan57702 Год назад +2

    HVAC

    • @jollyscaria1922
      @jollyscaria1922 7 месяцев назад

      Hl lowvol bor wre loose no selft ee wire cilp putther ok goodsheringallhigh low voltwire cilp very power passinv loose all cmpnet dsmges card fully

  • @tahirgujjar7476
    @tahirgujjar7476 Год назад +1

    Iove you ustad g....

  • @mdaabidhussain7734
    @mdaabidhussain7734 7 месяцев назад +2

    Bahi mujhe AC ka Kam Aata Hai overtime Karna Hai 9am se 5pm tak Kam hai HVAC ka full waring Aata hai

  • @nuruzzamannur8719
    @nuruzzamannur8719 Год назад

    Good job Dada

  • @PintuKumar-dc5tl
    @PintuKumar-dc5tl Год назад +1

    Sir ac panel terminal ka video banaiye

  • @aftabalam9286
    @aftabalam9286 11 месяцев назад +1

    Sir NO and NC per ek video please

  • @abdulmateen7951
    @abdulmateen7951 4 месяца назад +1

    Skm ka package unit ha low pressure ma trip hota ha gas ok solnit vole ok drier filter ok exp vole ok .new ac ha

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  4 месяца назад +1

      Bhai need to be checked something
      Like
      Loose connection check karo control ka wire fully tight or not
      V belt bhi check karo tight ok
      Or not
      Standing pressure and actual pressure compressor
      Blower rated amps and actual amps
      Duct bhi kya Naya hain?
      Dusra duct main damper laga
      Hai kya?
      Agar laga hai tou damper check
      Karo fully open ho raha hain ki nhi

  • @MohdShafeeq-hu2vq
    @MohdShafeeq-hu2vq День назад +1

    Bhai aap ne uvm ki wiring nahi bataya plz bataye

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  День назад +1

      Bhai Please watch this video,
      ruclips.net/video/fTGBnWTFd0o/видео.htmlsi=lqEVD-Lz2RiaUIji
      ruclips.net/video/UBvluHxU8Gk/видео.htmlsi=LInCzCmrdr7IalKw

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  День назад +1

      Aur baad main saprate video banayege

  • @mdmoin1193
    @mdmoin1193 11 месяцев назад +1

    Zamil Chiller ka code bataye

  • @iqbalgazi4492
    @iqbalgazi4492 Год назад +2

    Sir zamil package AC Mai FL error arah hay iska opuar AK video banaiye sir

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +3

      Bhai agar error code FL dikha raha tou
      Uske reason ye hain wo ya tou LP YA HP
      Switch se trip kiya hai
      agar PCBs board light slowly blinking kare tou wo lp switch se tripping huwa
      Aur fast blinking kare hp switch se trip huwa
      Aur lp mein agar trip huwa ho tou
      Check karo
      Freon pressure
      Lp switch
      Air filter
      Cooling coil
      V belt loose or damage
      And dumper
      Anti ice switch
      Hp switch
      Condenser motor
      Condenser coil dirt
      Loose wiring
      Condenser motor contactor
      Stuck
      Motor jammed

    • @iqbalgazi4492
      @iqbalgazi4492 Год назад

      @@HVACAMJADTROUBLESHOOT Thank you sir ❤❤❤

  • @ArshadKhan-lx3qd
    @ArshadKhan-lx3qd Год назад +1

    AC compressor Nahin chal raha hai sab Kuchh sahi hai

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      Bhai
      Agar compressor on nhi ho rha hai
      Tou kuch sahi ho sakta hai lekin
      Sab kuch sahi nhi ho sakta hai
      Agar sab sahi hoga to compressor
      On ho jyega, agar on nhi ho rha hai to
      Reason jarur hai,
      Sabse pehle
      c & g
      C & y1
      C & Y2
      mein voltage check Karo, 24 dikhana
      Chahiye aur abhi ketna dikha rha hai?
      Gas standing pressure ketna hain?

  • @zoinalabedin980
    @zoinalabedin980 Год назад +1

    Vai jan tharmostat ka connection kahun se o tho nahi bataya

  • @AhsanAli-ge2lj
    @AhsanAli-ge2lj Год назад +1

    Vmc ke cnecsion nahi bataye sir

  • @MdTokir-ug3wq
    @MdTokir-ug3wq 4 месяца назад +1

    Solo night ko pawar kaha se jata h

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  4 месяца назад +1

      Please bro watch this video
      ruclips.net/video/Got8DfUGzoQ/видео.htmlsi=IuI52lBos2ug70HV

  • @AzamAzam-fx1hy
    @AzamAzam-fx1hy 6 месяцев назад +1

    X1 aur x2 kis liye hota hai pcb me

  • @AbrarAhmad-sx7iq
    @AbrarAhmad-sx7iq Год назад +1

    Org light bilar kri he kya problam he sir

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      Bhai iske ye sab waja hone se
      Light 💡blinking hota hai
      1, loose wiring
      2,less freon or low freon
      3, belt loose
      4, filter dirt
      5,pcb board

    • @AbrarAhmad-sx7iq
      @AbrarAhmad-sx7iq Год назад +1

      @@HVACAMJADTROUBLESHOOT thanks

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад

      @@AbrarAhmad-sx7iq
      welcome bhai

  • @tiktoklover2464
    @tiktoklover2464 Год назад +1

    Sir transformed me 220v in nahi horay, yani cercit me 220v nahi arayh.,thermostat me current nahi aray,kya muskin ho saktahe

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      Bro
      Agar transformer ke 🔴 red wire mein 220 nhi dikha raha hai tou sabse phle
      Sab Phases voltage karo ⚡️aur phase
      Neutral mein bhi voltage⚡️ check kro
      Agar UVM ko bhi check karo,

  • @mustafaali3745
    @mustafaali3745 Год назад

    Bhai lock code bhi batiyega

  • @mohammedtanveer6148
    @mohammedtanveer6148 11 месяцев назад

    Zamil cassat a/c ka remote mobile may Kay say download karn plz batayn

  • @MdShahid-tt8rd
    @MdShahid-tt8rd Год назад +1

    Sir is me solinoid valve Ka connection nhi hai

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +2

      Bhai zamil ke kuch unit mein solenoid valve hota hai aur kuch unit mein nhi hota hai lekin
      agar solenoid valve ho tou pcb board main solenoid valve ka ek wire pcb main P1 main lagao system one ke liye lagao aur solenoid valve system 2 ke liye
      Pcb main P2 main ek wire lagao
      Aur dono systems solenoid valve ka dusra wire unit ATB terminal 2 main laga do, laikin solenoid valve 220 voltage coil hona chahiye

  • @Reyazvloge
    @Reyazvloge 9 месяцев назад +1

    Lp or hp kharab ho Gaya ho to bypass kaise kare zamil AC m

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  9 месяцев назад +1

      Video banayenge bhai laikin
      Lp aur hp ko sirf testing karne ke liye
      Hi bypass karen,

  • @Junedkhan75-
    @Junedkhan75- Год назад +1

    Sir zamil ka package unit hai uska blower motor nhi chal rha jab contector push krta hu tab chalta

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      Bhai sabse phale C aur G main voltage⚡️ check karo 24 dhik Hana chahiye agar dhika raha phir nhi blower nhi on ho rha hai tou blower contactor ka over load reset karo aur check karo aur ampere
      bhi check karo kyu over load se trip,
      Aur agar 24 voltage nhi dikha rha tou
      C aur G main phir ek single wire jumper
      Karo R aur G main sirf testing ke liye agar on ho gya tou phir thermostat main ya thermostat wire ka ya thermostat setting ka problem hoga
      Main

  • @sabiqansari3384
    @sabiqansari3384 10 месяцев назад +1

    No / nc ka btao bhai

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  10 месяцев назад +1

      ruclips.net/video/sn0_N7phkgM/видео.htmlsi=0BkU38sCOPqdU7lx
      ruclips.net/video/NlLcFT5iphc/видео.htmlsi=yqwMc77dm2-SsUyC

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  10 месяцев назад +1

      Aap ye video dekho

  • @MahtabAlam-mp8xn
    @MahtabAlam-mp8xn Год назад +1

    Compressors Contector coil / control 24v L N wire ke alawa baju me 3rd ek wire dikh raha hai wo kaisa wire hai ?

    • @MahtabAlam-mp8xn
      @MahtabAlam-mp8xn Год назад +1

      Wire cod 48 hai jo blower contector par laga hai wase hi compressors contector par bhi laga hai please us wire ke bare me batayen

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      bhai pch Neutral point mein two wires used kiya hain

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      @@MahtabAlam-mp8xn
      Dear Bro ,
      blower contactor ke auxiliary main
      wires number 48 aur 49 blower run for BMS indication ke liye used hota
      aur compressor contactor ke auxiliary main wires number 55 aur 56 compressor number 1 run for BMS indication ke liye used hota

    • @MahtabAlam-mp8xn
      @MahtabAlam-mp8xn Год назад +1

      Kya us wire ke na hone par contector chalu ho sakta hai ya wo wire pcb/transformer se series me hai ?

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      @@MahtabAlam-mp8xn
      Bhai zamil unit ka jo wiring 4 se 5 tarika hota hain same same model hoga likha hoga laikin wiring thora bahut fark hoga
      Kyu kuch unit mein SSPS hota hain kuch mai nhi kuch mai FCS used hota hain kuch mai nhi kuch mai anti ice used hote hai kuch mai nhi aur kisi bhi unit agar koi terminal mein wire double laga ho tou phale bhai check karna hoga ki wo wire kyu aur kis liye lagaya hai,,,
      Aur is ac mein jo double wire laga hai neutral terminal in the pcb board main agar wo hata de PCBs se tou koi unit ko problem nhi hoga unit theek se run karenga

  • @najishff694
    @najishff694 2 месяца назад +1

    W1 ky h

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  2 месяца назад +1

      W1 yani
      Jaise Y1 hota hain cooling ke liye
      Waise he W1 heater ke liye
      Thermostat se demand ataa hai
      Heater contactor ko on karne ke liye
      Bhaya

  • @yasirafzal4267
    @yasirafzal4267 Год назад

    P1 & P2 kis liye hai

  • @MuhammadNadeem-vc7zy
    @MuhammadNadeem-vc7zy Год назад

    In Dx unit there's not any system switch, one unit is running and second one on the rest why?
    CMY 300 FDAA

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад

      Bhai
      Zamil's package and all these models have no such switch yet to control both compressors But if there are two compressors in the system and not much cooling is required, then
      temperature from thermostat
      increase it & second compressor
      number two If the compressor is not
      to be run, the wire terminal of Y2 exit

    • @MuhammadNadeem-vc7zy
      @MuhammadNadeem-vc7zy Год назад

      @@HVACAMJADTROUBLESHOOT
      I exited Y1 but Y2 isn't switch on in after 5 minutes ?

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      @@MuhammadNadeem-vc7zy
      take out Y2

    • @MuhammadNadeem-vc7zy
      @MuhammadNadeem-vc7zy Год назад

      Kindly tell me about dip switch position.

    • @MuhammadNadeem-vc7zy
      @MuhammadNadeem-vc7zy Год назад

      CMY 300 system are lead or lag automatically?

  • @shakib_pathaan555
    @shakib_pathaan555 Месяц назад +1

    Assalamualaikum bhai jaan aapna no dege please

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Месяц назад +1

      Walaikum Salam wr wb bhai
      ruclips.net/video/GFpMfWUeTZ4/видео.htmlsi=V7ZQOSNqS9-chuWU

  • @tahirgujjar7476
    @tahirgujjar7476 Год назад +1

    Mere under big zamil units ha us ki bhi ik video bna do.

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +2

      Ok 👌
      Aapke site main kuan sa model ka unit hain please batao

    • @tahirgujjar7476
      @tahirgujjar7476 Год назад +1

      @@HVACAMJADTROUBLESHOOT 4 compressor wla

    • @tahirgujjar7476
      @tahirgujjar7476 Год назад +1

      @@HVACAMJADTROUBLESHOOT 4 compressor wala package unit ha 3 compressor on hota ha ik nhi ho rha sub kuch check kiya cammand bhi a rhi ha conctor push krne se on ho rha ha compressor

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +2

      @@tahirgujjar7476
      Bhai sabse phale pura wiring ko loose connection check karo aur tight karo phir on karke check karo agar same problem hain tou phir LP aur HP ko direct karo sirf testing ke liye phir check karo phir bhi same ho tou compressor contactor ka over load direct karo sirf testing ke liye
      Then on the unit and check the performance

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +1

      @@tahirgujjar7476
      Ok 👌

  • @manijesus1511
    @manijesus1511 Год назад +1

    Brother i have one doubt last 3 three same model skm package unit same pcb board after cutoff again not start unit what problem can you explain brother please can you send whats app number

    • @HVACAMJADTROUBLESHOOT
      @HVACAMJADTROUBLESHOOT  Год назад +2

      Bro
      Even if there is a problem in the package unit zamil or SKM and like this then some things must be checked
      like loose connection, LP HP switch, gas pressure, air filter
      clean or not, V Belt tight or loose and air return duct dumper fully open or not
      brother if you have any question you will get answer
      i getting too many messages by what's aap and phone calls and it is difficult to answer them all at once?
      And I have too much work load pressure right now