8 lead 3 speed mixi field coil winding connection with diagram|Mixer grinder winding connection

Поделиться
HTML-код
  • Опубликовано: 11 май 2023
  • 8 lead 3 speed mixi field coil winding connection with diagram
    Mixer grinder winding connection
    Mixi field coil winding connection
    Mixer grinder wiring connection
    750 Watts mixer grinder winding connection
    33 mm mixi field coil winding data
    Motor winding
    Mixi motor winding connection
    810 Watts mixer grinder winding 👇
    • Mixi motor winding|810...
    Single phase 4 pole motor winding👇
    • Wet grinder motor wind...
    Three phase motor winding 👇
    • 3 phase 2 hp 6coil 144...
    How to change mixi armature 👇
    • Preethi mixie repairin...
    Ceiling fan repair 👇
    • Crompton ceiling fan r...
    #mixergrinderwinding
    #mixicoilconnection
    #mixergrinderwiringconnection
    #mixifieldcoilwindingdiagram
    #8wiremixergrinderconnection
    #mixergrinderconnection
    #fieldcoilwinding
    #mixistatorwindingconnection
    #mixifieldpoleconnection
    #motorwinding
    #miximotorwinding
    #mixergrindermotorconnection
    #mixerwindingconnection
    #hipowerelectricworks

Комментарии • 19

  • @anuragverma8706
    @anuragverma8706 Год назад +2

    Bahut badhiya se bataye ho bhai

  • @CesarCemak
    @CesarCemak 5 месяцев назад +2

    Show top 🇧🇷 🇧🇷 🇧🇷 😊

  • @santhosh7304
    @santhosh7304 11 месяцев назад +1

    Super, I appreciate this presentation. More information in less time. Thanks. Please do more informations...

  • @narenderverma4203
    @narenderverma4203 9 месяцев назад +1

    ❤your vdo ❤

  • @rabishankarbiswas5929
    @rabishankarbiswas5929 7 месяцев назад

    Purane kharab coil se turn ko Kaise count karenge data ke liye ispar ek vdo banaiye

  • @lsraju
    @lsraju 7 месяцев назад +1

    Super explanation, thanks 🙂🙏

  • @krishnagowry
    @krishnagowry Год назад +1

    Good one.. Thank you.. 🙏👍👍👍

  • @user-vy6rg3cn4n
    @user-vy6rg3cn4n 11 месяцев назад +1

    Thank you very much.

  • @kajalpkdutta2194
    @kajalpkdutta2194 10 месяцев назад +1

    Nice technique

  • @vasikhan8219
    @vasikhan8219 Год назад +1

    Sir good video

  • @rashminaik6039
    @rashminaik6039 Год назад +1

    Nice...

  • @kironsk7697
    @kironsk7697 Год назад +1

    A single phase three speed blower motor was running slow with its high speed connection later on its stopped moving. Then motor was removed and has been run without load was running and the resistance of three of Coil was good.after that again I connect this motor with blower wheel and neither it was running nor it was taking amps . Please tell me what is the problem with this motor? As for the capacitor it's new .

    • @Hipowerelectricworks
      @Hipowerelectricworks  Год назад

      A thermal cut-off is connected to the common lead in the winding of the motor. Check if it is good.
      Check the resistance between the two wires connecting the capacitor.
      Check that the bushings on both sides of the motor are good. If the motor has bushing complaint or thermal cut off complaint of the motor then this complaint you mentioned is likely to occur.

  • @prathap7511
    @prathap7511 7 месяцев назад +1

    What is common lead for?

  • @mannkumar371
    @mannkumar371 Год назад +1

    Wire guage no. Sir

  • @kajalpkdutta2194
    @kajalpkdutta2194 10 месяцев назад +1

    Tar number