Temperature probes replacement on ARISTON Velis Evo electrical boiler

Поделиться
HTML-код
  • Опубликовано: 13 сен 2024
  • Temperature probes replacement on ARISTON Velis Evo electrical boiler.

Комментарии • 31

  • @patrickweigert7179
    @patrickweigert7179 2 года назад +3

    Thanks very much for the very helpful video!

  • @gabrieldemetz622
    @gabrieldemetz622 2 года назад

    Thank you so much for this video. This thing is pretty hard to open and operate !

  • @cajucosta
    @cajucosta 2 года назад

    Thank you very much! Very informative and helped me change mine!

  • @brahimourmail75011
    @brahimourmail75011 Год назад

    Merci beaucoup Man

  • @user-dt8tq3mw3d
    @user-dt8tq3mw3d 23 дня назад

    Hello, how did you know the probes were broken?

  • @user-qi6gx7oj7d
    @user-qi6gx7oj7d 6 месяцев назад

    Olá tenho o meu Ariston Velis 80L o display está piscar o que devo fazer?

  • @whandafigueroajimenez1101
    @whandafigueroajimenez1101 2 года назад

    From the cold water supply comes a plastic pipe to the wall. In mine, the water is always running in this plastic pipe, it is normal? Or do I need to do someting to stop it?

  • @adak4998
    @adak4998 2 года назад +1

    Hello, if the problem is that after the house lighting has fallen due to a light overload, after that the monitor turns on but only slightly illuminates the temperature 70 and 80? However it is no longer working. what should I do? thanks

  • @GlossaME
    @GlossaME 2 года назад +1

    Bune de ceva? Sau piese foarte scumpe? Merci

  • @TechdoLiberal
    @TechdoLiberal Год назад

    Hey chief! Have you ever worked with an Ariston lydos hybrid? I’m wondering if it has a serial port to send commands to, or, whether or not the board is accessible to look at the headers inside to hack it. Any hints?

  • @VoroninPavel
    @VoroninPavel 9 месяцев назад

    Thanks for the video. Mine one shows nothing for diagnostics. It's either turned off or on, no special lighting.
    And quite often it hangs showing all LEDs and eco mode on, and it does not react to buttons at all. Do you know what can be the reason?

    • @RICARDOJDS93
      @RICARDOJDS93 3 месяца назад +1

      Hi, did you solve this issue? I have the same problem

    • @VoroninPavel
      @VoroninPavel 3 месяца назад

      ​@@RICARDOJDS93unfortunately not, my landlord just replaced it with a new one.

  • @AnarGuitar
    @AnarGuitar 2 года назад

    Hello. So you got 2 different probes 65153300 and 65153301Which probes go to the left and right sides? Thank you!

  • @nutsukamataru3368
    @nutsukamataru3368 3 года назад +2

    hello , what shoud i do if all the lights are on and i cant turn them off and the water heater is not giving any signs of working ? ( i did all the combination of buttons possible , even unplug it for 5 to 10 min )

    • @chiefengineerslog4304
      @chiefengineerslog4304  3 года назад

      Just press and keep pressed for 5 sec the ON/OFF button. You should have a different light indication pattern if there is something wrong with your boiler. Once you see the specific light pattern than you can troubleshoot furthermore.

    • @nutsukamataru3368
      @nutsukamataru3368 3 года назад

      @@chiefengineerslog4304 yea i tried all the stuff and after that i just replace my 'motherboard'

    • @nutsukamataru3368
      @nutsukamataru3368 3 года назад

      now it works perfect.

    • @danielamorim8794
      @danielamorim8794 3 года назад

      @@nutsukamataru3368 I'm having the exact same problem. What's the solution? Do I have to call a Tec. here to fix it?

    • @nutsukamataru3368
      @nutsukamataru3368 3 года назад +1

      @@danielamorim8794 hello , i changed the 'motherbord' by myself (it is not really hard but be careful with the electric stuff ) and it works perfect now

  • @edgardeman5384
    @edgardeman5384 2 года назад +1

    my ariston velis evo 50 does not turn on, no led lights, what can i do?

    • @true-story-jb
      @true-story-jb 2 года назад

      does it solve the problem if yes what it had

  • @olgershaqiraj1982
    @olgershaqiraj1982 3 года назад

    Is this good product?

  • @michaelgerard4564
    @michaelgerard4564 2 года назад

    Hello, interesting to see how the NTC-sensors are changed.
    But why did you replace them? Did the boiler throw an error-code?
    Mine is showing LED2 and LED5 at the moment. Should have something to do with the NTC-sensor on the inlet-tank.
    Do you know the resistance-measurements to check if the NTC-sensor is faulty?

    • @800Javi008
      @800Javi008 2 года назад +1

      Exact same problem just after expiring warranty time...

    • @michaelgerard4564
      @michaelgerard4564 2 года назад +1

      @@800Javi008
      I had error LED 2 and 5. Problem with temp. on inlet tank. There was too much build-up between the resistance and the temp. sensor tube.
      Replaced both heater elements and anodes. Works perfect again.

  • @ouafaabarigo673
    @ouafaabarigo673 Год назад

    Slm