Marine Boiler Safety Valve || Why 10%Of Accumulation Pressure Not Exceeded? || Improved High Lift ||

Поделиться
HTML-код
  • Опубликовано: 26 ноя 2024

Комментарии • 10

  • @Dbmarine
    @Dbmarine Год назад

    Wonderful explanation..thank u..

  • @jjg0000
    @jjg0000 Год назад +1

    bhai manual is saying improved high lift safety valve lift should be d/4. you were saying d/12. which one is correct

  • @sundhard761
    @sundhard761 2 года назад +1

    Very good explanation bro..boiler full aah explain pannunga bro

  • @sujithsrirengan2917
    @sujithsrirengan2917 Год назад

    Sir, is there any difference between the compressor in refrigeration system and the compressor in other systems

  • @immanuvelgonsalves2438
    @immanuvelgonsalves2438 2 года назад

    Another great vedio 👍

  • @balajichandrasekar5005
    @balajichandrasekar5005 2 года назад

    Great information ❤️❤️ bro

  • @comoestas09
    @comoestas09 2 года назад

    Bro. All you other videos were really informative and clear in concepts. But this one isn't upto the mark.

  • @mandeepsingh8722
    @mandeepsingh8722 Год назад

    poor video