DISTANCE RELAY || CALCULATION OF DIFFERENT ZONE SETTINGS ( PART-1)

Поделиться
HTML-код
  • Опубликовано: 29 ноя 2024

Комментарии • 23

  • @prithivirajhr7606
    @prithivirajhr7606 2 года назад +2

    very nice , informative

  • @patakotisrinivas1918
    @patakotisrinivas1918 Месяц назад

    Nice explanation bro 👍

  • @alok171
    @alok171 2 года назад +2

    Nice explanation of the topic

  • @king-pirates_coc8364
    @king-pirates_coc8364 Год назад

    I love Your explanation. Upload more videos with verious topics & also teach us relay configurations. 🙏🙏

  • @surendrakverma555
    @surendrakverma555 2 года назад +1

    Very good 🙏🙏🙏🙏🙏

  • @arifhussain-wx7bb
    @arifhussain-wx7bb 2 года назад

    Thankyou so much sir, today i understand how we do settings in this relay.
    Need ur support, make video like this.

    • @relayprotectionelectrical
      @relayprotectionelectrical  2 года назад

      Thank for watching. There are three parts for calculating settings of distance relay. You may also go through other two parts also.

  • @vinotharumugam7630
    @vinotharumugam7630 5 месяцев назад

    How we select the tripping time for 300 to 350ms we have any standard or it is in some practice.

  • @ImranKhan-nu6xw
    @ImranKhan-nu6xw 3 месяца назад

    Why we not consider transformer impedance in zone 2,as the first transformer at substation B comes in zone 2 area??

    • @relayprotectionelectrical
      @relayprotectionelectrical  3 месяца назад

      @@ImranKhan-nu6xw Zone -2 reach is considered to cover the impedance reach of far end busbar fault.

  • @udhayakumart4375
    @udhayakumart4375 9 месяцев назад

    Good information. Thank you. I am also protection engineer. So I have a doubt, did you ever try to test the mutual compensation in distance rely p444 with realy test ki. If so, please share. Thank you.

    • @ninojamescagat9780
      @ninojamescagat9780 8 месяцев назад

      Good Day sir, as an aspiring protection engineer can i ask you sir for any tips you can give to me that should i do from the start of learning. Thank you sir

  • @AllanFHarun
    @AllanFHarun 2 года назад

    wher did you get time (T)?

  • @rajanbudhathoki
    @rajanbudhathoki Год назад

    why not considered R0 ,X0 and Xm in calculation??

  • @memorablelamhe3188
    @memorablelamhe3188 2 года назад

    If line length is less than 100 km then what should be percentage of z4?

  • @gokulgopi6573
    @gokulgopi6573 Год назад

    CT ratio/PT ratio
    How did you get 800/1200
    Please explain

    • @TheRealBarryR
      @TheRealBarryR 8 месяцев назад

      (ratios are primary (line value) / secondary (transformed value for measuring)). Current transformer ratio is 800/1 (=800), and Potential transformer is 132/sqrt(3) kV (its kV!) and 110/sqrt(3) (=1200) .

  • @amansahu7679
    @amansahu7679 Год назад +1

    Hindi m bol lo jayda like hoge....😂