Это видео недоступно.
Сожалеем об этом.

COMBI BOILER,TEMPERATURE SENSOR TEST,THERMISTOR TEST

Поделиться
HTML-код
  • Опубликовано: 20 янв 2013
  • This video is how to test combination boiler temperature sensors.
    Any video request please comment and I'll try my best.
    Please Like and comment

Комментарии • 44

  • @kombiteknikservisi
    @kombiteknikservisi 8 лет назад

    Kombi sensör arızasını anlaya bilmek için açıklayacı video. Ustaya teşekkür etmek lazım.

  • @BADMANDONS21
    @BADMANDONS21 9 лет назад

    Great video, clear explanation. I have central heating working fine but no hot water. I have been informed that DHW Thermistor could be an issue as boiler does not know of problem. Thanks I will try your video explaination.
    Jay

  • @TheDickPuller
    @TheDickPuller 11 лет назад +3

    Great video mate, please do more on components testing it's always good viewing.

  • @loghead8615
    @loghead8615 10 лет назад +2

    A thermister can go open circuit when resistance increases/decreases so dont take it for gospel they are ok... (Had a few thats done it)

  • @acrestones
    @acrestones 10 лет назад +2

    Hi really really like your video well explained really appreciated to you for share your knowledge with us
    Kindly please can you upload more videos like how to check boiler fan & air pressure switch & more like boiler fault finding & Diogenes
    Thanks a lot

  • @foxyhlc
    @foxyhlc 10 лет назад

    Good job and thanks for giving this information.

  • @woodbine66
    @woodbine66 11 лет назад

    Yes, .more component testing vids please. Pumps, valves, boiler internals.
    Many thanks.

  • @Eatherz
    @Eatherz 11 лет назад

    EXCELLENT VIDEO , as i was looking for a new meter after getting some funny readings off my tpi ez100 ..

  • @Taqqiyastar
    @Taqqiyastar 11 лет назад

    Excellent video well explained about thermistors
    Please upload more video about boilers such as diverter valve/diaphragm etc.
    Thanks

  • @redrock1963
    @redrock1963 4 года назад

    I believe when you tested the second thermistor the lead tips were touching and that's why you got the O.L reading....then when you moved you got a correct reading. You remind me of tradies I've hired here and cost me more $$$ then needed.

    • @TW-mp8zx
      @TW-mp8zx 4 года назад

      redrock1963 im just comparing these readings he got the first one was correct for room temperature, and the second one of 9000 is showing a temperature of around 27 Celsius.. I wouldn’t say that’s too problematic if anything the boiler might cycle on and off at lower deltaT room temps..

    • @martinb6079
      @martinb6079 3 года назад +1

      If the lead tips were touching you wouldn't get a O.L reading (basic electronics testing). You would get 0.1- 0.9 ohms like he showed earlier in the video.

  • @TippTopp81
    @TippTopp81  11 лет назад +1

    I'll try to do a clip on air pressure switches in the next few days.

  • @neilcarroll4579
    @neilcarroll4579 3 года назад

    Just a quick question please , my heating hasn't been on all summer (turned to dhw only ) , however water has been hot as normal , pressure is fine , however water often goes cold , from these videos it sounds like the temp sensor , however pilot light goes out , would pilot light go out if bad hot water sensor and dhw on only ? Thanks

  • @AnthonyFrancisJones
    @AnthonyFrancisJones 2 года назад

    I may be missing something here but the 10k and second one at 9k are almost the same resistance so both registering around room temp. 80 degrees C would be about 4k - I am not a heating engineer so what am I missing here??

  • @acidtechno
    @acidtechno 6 лет назад

    great vid , replaced 3 of these in one year .. how come they keeping going wrong? never had to change one in 10 years and now three in less than a year ??

  • @TippTopp81
    @TippTopp81  11 лет назад

    KaneInternational do a great set of clips on Flue Gas Analyses on youtube. But when i get a chance to do a vid on site i'll do one.

  • @asengsaputra288
    @asengsaputra288 Год назад

    Hello sir l have sensor boiler temperature, 3 wire cable color : Red,blue and white but l dont now type of sensor RTD or Thermocoule .
    Please help me sir
    Thank you…

  • @richiefinn
    @richiefinn 4 года назад

    Does it matter which wires go on which terminal mine are independent, not in a block thanks

  • @yusufrehman2157
    @yusufrehman2157 5 лет назад

    Please make live and dead test of each component of boiler

  • @ianwilliams4787
    @ianwilliams4787 5 лет назад

    Would this explain why the hot tap runs hot then cool ?

  • @loghead8615
    @loghead8615 10 лет назад

    Very well explained tho

  • @DavidSmith-cz9zv
    @DavidSmith-cz9zv 5 лет назад

    If I unscrew this from my boiler will water come out. Or is it sealed in a pocket

  • @OreecleTV
    @OreecleTV 10 лет назад

    well explained thanks.

  • @leonagraca2239
    @leonagraca2239 5 лет назад

    Ok so we don't have a fluug so what do we do guess what ohms it is to be set?

  • @possle
    @possle 11 лет назад

    Is the for all thermistors or do different ones have different ohms ratings.

  • @MrSTUPIDBRICK
    @MrSTUPIDBRICK 11 лет назад

    any chance of a tutorial on flue gas analysers please

  • @BarbellMonkey
    @BarbellMonkey 6 лет назад

    Hi, when removing these sensors.. Do you need to drain the boiler or anything like that? Will water be behind the sensor?

    • @TippTopp81
      @TippTopp81  6 лет назад +1

      MonkeyPumpkin some are dry pocket but I'd drain it to be sure.

    • @BarbellMonkey
      @BarbellMonkey 6 лет назад

      TippTopp81 thank you very much for the reply!! :)

  • @wilburcartwright5068
    @wilburcartwright5068 7 лет назад

    11.000 to 13.000 oms is when the boilers cold what should it read when boilers running???

    • @leaturk11
      @leaturk11 6 лет назад

      These work by decreasing the resistance proportionally with an increase in temperature, for example 25 degress C to start at 12,000 Ohms, to 55 degrees C at 4,000 Ohms. As temperature goes up, resistance comes down.

  • @markzola8142
    @markzola8142 6 лет назад

    Hi,my boiler keeps shutting down when i run a bath,could it be a faulty thermister?

    • @knapman1990
      @knapman1990 5 лет назад

      Blocked plate heat exchanger 👍

  • @ArksE8
    @ArksE8 9 лет назад +1

    Only if the thermistor is an NTC.

    • @KarateCritic
      @KarateCritic 5 лет назад

      Yes. No mention of NTC vs PTC thermistors. Otherwise good info. Cheers!

  • @taab7
    @taab7 6 лет назад

    Where do you put the probes on a single pin sensor?

    • @anthonycosta2613
      @anthonycosta2613 6 лет назад +1

      taab7 one side on the pin the other side to earth

  • @TheTomplum
    @TheTomplum 11 лет назад

    tipptopp, you sound like a Wiganer, are you? good vid BTW

  • @TippTopp81
    @TippTopp81  11 лет назад

    I'll try to do a clip on air pressure switches in the next few days.

    • @umark6695
      @umark6695 6 лет назад

      TippTopp81 Nice video. We're still waiting for the new video ;)