Installation example of a Thermex ID Shadow horizontal electric water heater

Поделиться
HTML-код
  • Опубликовано: 3 фев 2025

Комментарии • 22

  • @funwithrepair
    @funwithrepair 3 года назад +2

    Hi. Just noticed that in the video you installed the teflon tape counterclock wise the first time but the second one was indeed the correct way...thanks for sharing. Goodluck.

    • @KIIPimport
      @KIIPimport 3 года назад +2

      You are right. It is better to apply the teflon clock wise. Thanks

    • @florino6556
      @florino6556 2 года назад

      Also he didn't remove the screw from the directional valve

    • @KIIPimport
      @KIIPimport 2 года назад +1

      @@florino6556 you don’t have to remove the screw from the 3-way safety valve. Only if you wish to drain the water heater through the valve you need to remove the screw. It’s there so no one can accidently drain the water heater.

    • @florino6556
      @florino6556 2 года назад +1

      @@KIIPimport it's pressure release valve.Some of them don't even have that screw

  • @rdginstalaciones6207
    @rdginstalaciones6207 2 года назад +1

    Lo primero, tienes que saber colocar el teflón. Y luego saber que los flexibles llevan orings

    • @KIIPimport
      @KIIPimport 2 года назад

      Efectivamente, la dirección de la cinta de teflón estaba equivocada. Es mejor aplicar en el sentido de las agujas del reloj. Las mangueras flexibles tienen juntas tóricas, la válvula de seguridad no. Incluso con los sellos de goma, se recomienda usar cinta de teflón para aislar los conectores de la rosca.

  • @pacobueno7
    @pacobueno7 2 года назад +1

    Manguitos electrolítico??

  • @sandiguzeto7855
    @sandiguzeto7855 2 года назад

    браво ❤

  • @chazhodge8768
    @chazhodge8768 2 года назад

    Where does the pressure go? Is there no vessel?

    • @KIIPimport
      @KIIPimport 2 года назад

      A pressure release valve is included in the package. It’s the part that is attached to the cold water inlet. No expansion vessel needed

    • @chazhodge8768
      @chazhodge8768 2 года назад

      @@KIIPimport It’s an unvented heater, you have to allow for expansion, a pressure release is a last line of defence 🙄

    • @KIIPimport
      @KIIPimport 2 года назад +1

      @@chazhodge8768 no, this is how it‘s done. The valve drains small bits of water to the siphon. In the EU no Expansion vessels are being used with unvented storage water heaters.

    • @chazhodge8768
      @chazhodge8768 2 года назад

      @@KIIPimport 😂😂 ⏰ 💣

  • @robertomarino
    @robertomarino 2 года назад

    Bel video, mi sono iscritto al tuo canale, così contribuisco alla tua crescita

  • @abdurahmanjabir4588
    @abdurahmanjabir4588 2 года назад

    How many mint needs to het woter

  • @vinnysciortino4211
    @vinnysciortino4211 3 года назад +1

    How to replace the hose?

  • @juniorsport5880
    @juniorsport5880 2 года назад

    The background music is great. Can i have a link to the artist?

  • @blinov7368
    @blinov7368 2 года назад +3

    Не дай бог такого сантехника пригласить. 🤔

  • @chauffe-eautechnique4252
    @chauffe-eautechnique4252 2 года назад

    Ils faut que tu installé les raccord galvanisé

  • @nikolanikolic6985
    @nikolanikolic6985 2 года назад +1

    E ovako se ne radi,dihtuje tamo gdje ima dihtung.

    • @KIIPimport
      @KIIPimport 2 года назад

      Preporučuje se malo teflonske trake. Izoluje konektor od navoja. Nije neophodno ali se preporučuje.