Wow they have improved there controls its been 20 years since I worked transport refrigeration I switched to Commercial but I miss working on containers
In MSC all units are Carrier, my opinion better to have on board only one maker of unit, more faster to troubleshoot, and only one set of spare parts.... Looks like Maersk also going to have only StarCool... Colleague your videos is good, i am also ETO make videos of jobs on board containers ships)) Later on i will made advertising your channel for my subscribers, you make good explanasions in English for them will be very good to learn. Best Regards.
@R G, during MSC charter i see only few units starcool and that units was from subcharter and not related to MSC. About Maersk under charter and original, more and more starcools on board their vessels and maybe after couple of years will be only StarCool...
thnk u so much sir , keep making more new videos for us newbies to have guidance and reference abiut reefer container, sir tanong ku lng po sana anu ba ang normal suction pressure and discharge pressure in a normal running reefer containers po? salamat po sir
I’ve just started working on REEFER units coming from an AC background… any pointers or things to keep an eye out for? I’m very new to it but keen to become very knowledgeable. Thanks !
They are strategically place in different areas where weight was distributed, considering they are special containers, accessibility , and power is supplied individually to every container position.
Some of control panels dont give you much room to work at componates relays contactors and control boards, would be a great help to you if they used the same manufactor all the time cause you would only need 1 set of spare parts make your job easier.
Sir, ask ko lng if possible ma convert sa single phase yan? Meron ksi dto sa amin subrang mahal mg pa kabit NG 3phase sa utility..tas mababa lng nman load ang container.. Ty po
If you have a limiter active, usually it is shown on a display, what kind of limitation you have, for example if you see FCTemp next to Limiter it means that the limitation is because of the FC high temperature (higher than 75 deg).
Hey mate need some help.Was getting a E205 alarm on a daikin freezer container ( evaporator fan motor failure)Changed one of the evaporator fan motor because it had a bearing issue. After hours of operation the same alarm still appears. I’ve checked the running amperage of both motors and they appear to be fine. Is there something I’m missing?
My carrier refer containerfreezer is totally out.power supply is okay.alarm is at AL52.xan you tell why the unit is not coming in.even evaporator fan motor not coming in.
Hi Lecky, I noticed that freezer container has 25Amp Max Draw.. does it draw up to 25amps or less? In a slight problem ATM my container I just bought is 25amp but my wall socket is only 20amp? Any suggestions?
Sir Jake good day po may plano po ako mag training po sa meridian for 5 days about reefer maintenance and troubleshooting hindi po ako eto or etr techvoc po ako graduate as a aircon tech. Ask ko lang po if ever matapos ako sa training ko na 5 days sa meridian may chance po ba ako makasampa? Tsaka if ever po ba kahit hindi eto or etr pede parin mag apply as reeferman lang on board po? Salamat po keep safe always.
Tharmoking also two different model and starcool also two different model Thermo king is mp3000 mp 4000 And starcool sem5 and sem6 You forgot one more unit it’s Mitsubishi unit Mostly this unit coming or hapag Hollyd line
Last time I had a Daikin with fluctuating voltage. It was showing around 300 VAC. Unit stopped and couldn't start. I checked all voltages also on the connector to the PC/CT board. They were ok. I replaced this board and after connecting to the power socket I got the same 299 VAC fluctuating a little. Then I changed the socked, already the 3rd time. I got 360 VAC but it was enough for the unit to start. Voltage was stll fluctuating but every day unit was running and the voltage was going towards 450 VAC still fluctuating a bit. All happened when we were crossing the Equator. I think that the ambient temp was the problem, however this unit was on deck.
Hello sir, its good to see you are working with maersk.. Tanong ko lang po ung reefer settings po ba VENTILATION is same as VENTILATION DELAY? magkaiba po kaze ung settings while booking sa maersk, hapag and CMACGM. like for example Temperature is 13C Ventilation 30CMH anu po ba ibig sabihin nyan? thank you po sa sagot in advance.. Keep Safe..
@@leckyjake maraming salamat po sir sa mabilis na reply. last na lang po, delay po kaze ang sabi hindi open, pareho lang po ba yun? nalilito po ako... huhuhu
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much help pls
Hahaha why all crying about the carrier thermoking and daikin and the new one carrier prime line one and othe use like Freon co2 and what about the new controller from carrier ML5
Iam a trainee eto. Your videos are much greatful for all eto cadets careers sir.
Thank you
maraming salamat po sa informative videos nyo.. mlaking tulong sa mga racKiztah... newbies Ref and aircon technician. god bless you
Wow they have improved there controls its been 20 years since I worked transport refrigeration I switched to Commercial but I miss working on containers
Salamat sir idol. Laking tulong ang channel nato saming mga baguhan.. 🙏👍
Thank you
Please keep them coming brother.
Watching from Oakland CA
buy 20ft refrigerated container online
postfirstclass.com/product/buy-20ft-refrigerated-container-online/
postfirstclass.com/product/buy-20ft-storage-container-online/
In MSC all units are Carrier, my opinion better to have on board only one maker of unit, more faster to troubleshoot, and only one set of spare parts.... Looks like Maersk also going to have only StarCool...
Colleague your videos is good, i am also ETO make videos of jobs on board containers ships))
Later on i will made advertising your channel for my subscribers, you make good explanasions in English for them will be very good to learn.
Best Regards.
@R G, during MSC charter i see only few units starcool and that units was from subcharter and not related to MSC. About Maersk under charter and original, more and more starcools on board their vessels and maybe after couple of years will be only StarCool...
Very interesting,good luck for you.
Sir me too from marine . a awsome video on this field first time
Thank you for the support
buy 20ft refrigerated container online
postfirstclass.com/product/buy-20ft-refrigerated-container-online/
postfirstclass.com/product/buy-20ft-storage-container-online/
I have learned as lot from your videos. 👍
Thank you sir, give the knowledge,improve new technology of coolers of machineries
Hi , dear Leckyjake, your videos are very educational , thank you for so very useful videos.
thnk u so much sir , keep making more new videos for us newbies to have guidance and reference abiut reefer container, sir tanong ku lng po sana anu ba ang normal suction pressure and discharge pressure in a normal running reefer containers po? salamat po sir
sir god bless po sayu...very useful po mga video mo sir.. maraming salamat po
I enjoy watching your videos. Please go through one wiring diagram explaining controls.
Thank you sir.. Very informative.. More about types of tripping and alarms
Great explanation sir
The guy really loves a star cool
Thanks ka lecky very informative
Thank you lods
I’ve just started working on REEFER units coming from an AC background… any pointers or things to keep an eye out for? I’m very new to it but keen to become very knowledgeable. Thanks !
starcool is everyone's favorite. Carrier is a pain in the ass
Very informative leckyjake, all of your videos ..❤️ soon I will handle reefer container .then I make vlogs also ..
Very good teachings
Good lessons of coolers
Sir , thank you so much for all of your videos 🙏🏻 never stop making content for us 🙏🏻 pls teach us some troubleshooting on Alarm Monitoring system🙏🏻
👍👍👍👍
Hi I am from India.. I want to learn whole things about reefer container is there any source to learn? Any website or Book? Please suggest me
Awesome video !
Very interesting. Do reefers have to be located in particular areas of the ship, or is power supplied to every container position?
They are strategically place in different areas where weight was distributed, considering they are special containers, accessibility , and power is supplied individually to every container position.
We need more refrigeracion videos please!!
Some of control panels dont give you much room to work at componates relays contactors and control boards, would be a great help to you if they used the same manufactor all the time cause you would only need 1 set of spare parts make your job easier.
Please make video for generator . Thanks lecky
Who deals with the refrigeration piping, changing filterdriers and other components in the refrigeration pipe system.
Like and AC contractor reefer techs do it all
شكرا للترجمة❤
E903 daikin. Most common problem?? Thank you thank you
good video thank very much
Thanks 💯
can you explain how these chillers get their power sources from?
Ship power supply or land power?
@@sambaker3233 but exactly how?
@@ShopperPlug From power sockets 440 VAC for instance installed on board.
done idol thanks sa video
Please make one vedio how to collect refer container data in pd please its urjent
Sir can you explain about reading the diagrams
nice idol
Thank you
Sir more uploading on carriers, like insufficient cooling and compressor preventive maintenance
salamat idol..
Salamat sa support
Yeah thermo king dosnt seem to think about service when engineering equipment, it's the same for thier OTR equipment.
good morning, I am having a AW306 shp and the unit doesnt initiate to start. Any solution? thank you.
leckyjake engat sa work GOD BLESS
Safe sailing too
@@leckyjake chat.whatsapp.com/La7y2ZfC2xFGEatw401T7m please join this reefer troubleshooting group sir... Thank you
thanks
Pre dyan sa barko di naman gaano kadalas ang troubke
Can someone please tell me, should the evaporator fans always be running 24/7? I have a carrier thinline
depends on the temperature. once reached the setpoint it will stop running.
Sir, ask ko lng if possible ma convert sa single phase yan? Meron ksi dto sa amin subrang mahal mg pa kabit NG 3phase sa utility..tas mababa lng nman load ang container.. Ty po
What’s does limiter active mean on a starcool unit
That’s usually because of the genset running on low speed.
If you have a limiter active, usually it is shown on a display, what kind of limitation you have, for example if you see FCTemp next to Limiter it means that the limitation is because of the FC high temperature (higher than 75 deg).
Hey mate need some help.Was getting a E205 alarm on a daikin freezer container ( evaporator fan motor failure)Changed one of the evaporator fan motor because it had a bearing issue. After hours of operation the same alarm still appears. I’ve checked the running amperage of both motors and they appear to be fine. Is there something I’m missing?
Probably the splice inside the motor, wire connector wasn’t crimped right but check the contractor first.
Iam working on a thermo king reefer which is switching off both circuit breakers.what could be the problem ?
❤️❤️❤️🙏ty brother make more videos 🙏
Job rac .I am form India .
My carrier refer containerfreezer is totally out.power supply is okay.alarm is at AL52.xan you tell why the unit is not coming in.even evaporator fan motor not coming in.
Hi Lecky, I noticed that freezer container has 25Amp Max Draw.. does it draw up to 25amps or less?
In a slight problem ATM my container I just bought is 25amp but my wall socket is only 20amp? Any suggestions?
19 Amps is the highest.
How can I reach you personally to discuss some matters?
Sir Jake good day po may plano po ako mag training po sa meridian for 5 days about reefer maintenance and troubleshooting hindi po ako eto or etr techvoc po ako graduate as a aircon tech. Ask ko lang po if ever matapos ako sa training ko na 5 days sa meridian may chance po ba ako makasampa? Tsaka if ever po ba kahit hindi eto or etr pede parin mag apply as reeferman lang on board po? Salamat po keep safe always.
Tharmoking also two different model and starcool also two different model Thermo king is mp3000 mp 4000 And starcool sem5 and sem6 You forgot one more unit it’s Mitsubishi unit Mostly this unit coming or hapag Hollyd line
Thanks lecky
Do one in thermoking
my friend u share some reefer container electric electronics drawings
:) thnx lecky
When there is a problem then who pays the costs of repairing the container?
Hi Sir. San Po may training school dito sa Manila
Hello will u plz tell me about the parts or maintenance/service of carrier prime series me from Pakistan and waiting for ur reply.
Hello sir i m reefer Technician How Apply job Reefer Technicians on vessel can give some tips
Good day sir jake. Pwede ba ako maka sampa nang cadet elect. 1 year lang experience sa planta? Salamat sa sagot sir and Godbless sa iyong paglalakbay.
Yung requirements nasa Marina page
@@leckyjake salamat sir jake.
Bruh .. I found digital valve error in thermoking mp3000 reefer ... How can I solve it
Last time I had a Daikin with fluctuating voltage. It was showing around 300 VAC. Unit stopped and couldn't start. I checked all voltages also on the connector to the PC/CT board. They were ok. I replaced this board and after connecting to the power socket I got the same 299 VAC fluctuating a little. Then I changed the socked, already the 3rd time. I got 360 VAC but it was enough for the unit to start. Voltage was stll fluctuating but every day unit was running and the voltage was going towards 450 VAC still fluctuating a bit. All happened when we were crossing the Equator. I think that the ambient temp was the problem, however this unit was on deck.
Does problems in reefers occur daily?
@@kabishek5003 Yes. If you have 1400-1500 reefers the probability is higher...especially in hot areas.
What is the requirements...to do a training of reefer container...I really want to undergo training so that I can be like you.....
I am a aircon and ref. Technician
Hello sir, its good to see you are working with maersk.. Tanong ko lang po ung reefer settings po ba VENTILATION is same as VENTILATION DELAY? magkaiba po kaze ung settings while booking sa maersk, hapag and CMACGM. like for example Temperature is 13C Ventilation 30CMH anu po ba ibig sabihin nyan? thank you po sa sagot in advance.. Keep Safe..
30 CMH means 30 cubic meters per hour. ito yung ventilation setting or opening ng vent ng reefer mo.
@@leckyjake maraming salamat po sir sa mabilis na reply. last na lang po, delay po kaze ang sabi hindi open, pareho lang po ba yun? nalilito po ako... huhuhu
Sir matanong kulang po kung anu ang advantage and disadvantge sa reefer ship sa mga Marine???bagong graduate po..sana ma sagot po😊😊😊..salamat
Advantage is maraming exposure sa High Voltage system and Refrigeration. Disadvantage is mas pagod sa pag check nf reefers and madalian ang port stay
@@leckyjake salamat ng sobra sir😊😊
Hamburg sud Vessel?
I want to learn. Can you teach me?
Reefer container technician job video
Hi I am from India.. I want to learn whole things about reefer container is there any source to learn? Any website or Book? Please suggest me
Lên trang chủ của từng hãng sản xuất như Daikim. Starcool. Carier và thermo king. Đều có sách hưỡng dẫn cho từng model
What is the salary of this referral technician?
Hi, would like to purchase reefer container 20ft ,any one assist with contact
Nice video sir , dear can I contact with you? I sent to you in instagram please answer me if you can,I have questions about ETO I have interview
buy 20ft refrigerated container online
postfirstclass.com/product/buy-20ft-refrigerated-container-online/
postfirstclass.com/product/buy-20ft-storage-container-online/
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much help pls
better check the power mess card
I need to use my pepe?? I dont think so 2:00
Hahaha why all crying about the carrier thermoking and daikin and the new one carrier prime line one and othe use like Freon co2 and what about the new controller from carrier ML5