Invt 25 hp ki drive hai usme frequency varry nhi kr hi hai load badne per dc voltage down hoker moter trip ho jati hai aur Uu ka fault ata hai aur Pb group ki setting bhi nhi hai
Sir I have GD200A VFD I want use there enable. Means on off drive than I connect the potential meter for set the speed one push button for inch reverse can u tell me parameter setting
Sir mujhe or ek help kijiye.. speed increases or decreases karneke bad rpm jaha par set rahega, drive stop karneke bad fir jab start hoga tob speed Apne ap increase hoke ohi rpm me Jake set hoga. Jeyse potentiometer me hota he. Iske liye drive me parameter setting key hoga.... please sir, thanks
Sir please ht spi 3003_2 ka modal drive ka drive chalu Karo to frequency bhi 50 hz chali jati hai aur mujhe s1 or com terminal se sirf chalu karna hai drive aur Al2 or10 v or gnd se frequency slow fast karna hai pls sir batayiye
Can you please let me know the parameter setting if my PLC start stop command is holding which is connected to S1? If S1 high, drive shall start & if low then drive shall stop.
Thanx Deepak sharma for your comment. I think that the parameter mentioned in this video are same for the vfd you mention. If have any queries please feel free to comment. Thanx
Hello sir Gd20 004 g 4 Potentiometer ke liy P00.06-1 se nhi ho rha he sir Display 0.00 bata raha hai P00.06-0 se keypad se nhi ho rha Display frequency show honi chahiy {exam. 50.00} vo nhi ho rhi he Plz... Help me sir
S3 terminal default fault reset ke liye programm hota he agar apko dusre terminal ko programm Karna he to us terminal ke parameter me 7 dalne se fault reset ke liye programm ho Jayega.. No push button ka Connection com and s3 ke bich Karna padega..
Invt 25 hp ki drive hai usme frequency varry nhi kr hi hai load badne per dc voltage down hoker moter trip ho jati hai aur Uu ka fault ata hai aur Pb group ki setting bhi nhi hai
Invt 25 hp ki drive hai usme frequency varry nhi kr hi hai load badne per dc voltage down hoker moter trip ho jati hai aur Uu ka fault ata hai aur Pb group ki setting bhi nhi hai
Thank you Sir! very good explanation, you save my day !
Very helpful 😊
Thank you so much
सर हमें पुश बटन से स्पीड कम या ज्यादा करनी है
साथ में पुश बटन से ही स्टार्ट, स्टोप करना है।
Slow/fast push button ka wiring bataiye.
Sir I am using gd 20 series 4 kw 3 phase solar INVT drive
My doubt can I give EB INPUT SUPPLY
Sir I have GD200A VFD I want use there enable. Means on off drive than I connect the potential meter for set the speed one push button for inch reverse can u tell me parameter setting
Thank you so much sir
Sir..invt good drive10 me push button switch se speed increases or decreases parameters or control terminal key y hoga.. please.. thanks
P0.06= 0 ( Freq. Command)
P5.03(S3 terminal) =10(Speed inc)
P5.04(S4 terminal)=11(speed dec)
@@niceelectronics9505 thank you very much sir..
Sir mujhe or ek help kijiye.. speed increases or decreases karneke bad rpm jaha par set rahega, drive stop karneke bad fir jab start hoga tob speed Apne ap increase hoke ohi rpm me Jake set hoga. Jeyse potentiometer me hota he. Iske liye drive me parameter setting key hoga.... please sir, thanks
Usme default set hi he frequency save hi rahegi power off karne par bhi.
@@niceelectronics9505 thanks sir..
Sir please ht spi 3003_2 ka modal drive ka drive chalu Karo to frequency bhi 50 hz chali jati hai aur mujhe s1 or com terminal se sirf chalu karna hai drive aur Al2 or10 v or gnd se frequency slow fast karna hai pls sir batayiye
Sir
Gd20 5hp मोडल में पोटेंचोमिटर key ped वाला use करना है
पैरामीटर plz....
P0.06 = 1
Hi.
How to chenge the relay function. RO1 is damaged. Can I shift it to RO2
Can i run 1 hp ac pump directly from solar panel?
Sorry you can't run AC pump directly from DC supply you need solar vfd to run it.
@@niceelectronics9505 i want to ask can i run 1 hp ac submersible pump through solar using solar vfd ?
Yes you can.
Can you please let me know the parameter setting if my PLC start stop command is holding which is connected to S1? If S1 high, drive shall start & if low then drive shall stop.
how to synchronise this drive pls share in your next video
ruclips.net/video/K6WO5vn_c00/видео.html
Sir external terminal ko use and supply dite hai GD200Adrive pls check Sir PLC start -L +L ki supply a rhi hai external terminal used for drive start
Please my help
मुझे sir 3hp invt gd100 2r 2g s2 pv मोडल है
उसमे 1hp का सिंगल फेस मोटर चलाना है
Plz
पैरामीटर बताया
ruclips.net/video/sDtX_wv9d2k/видео.html
GD20 ड्राइव से क्या सिंगल और ट्रिपल फेस ले सकते हैं सोलर से।
S1 and S3 alag / alag frequency
Set ker ke dono ko forward mode mein kaise chalega
Ak video program base b bna dein for selector switch and potentiometer
Is video me Mene programming and wiring bataya he selector switch and potentiometer.
Sir dhanyawad 🎉
🙏Thank you sir 🤝
Hello, do you need accessories for GD200A?
Please suggust us programe setting when we use s1 for strat/forward s2 for Start/ reverse S4 for reset , S5 for speed up and S6 for speed down
10hp motor ki Crompton ki fully loaded setting ki video banao
Please do it Mitsubishi D700 programming
सर मेरे घरgd200 लगी है इससे हम घरेलू कनेक्शन कैसे ले यानी न्यूटन प्लस फेस
Sir invt g10 ka wiring and programming ka video daliye
I will do in this in upcoming days when I have this vfd.
Awesome knowledge thanks
Sir invt GD200 increase decrease push button parameter bata sakte ho
Super nice 👍👍👍❤❤
Frequency push button se slow fast krna he and jab bhi vfd stor kare to Frequency zero se start honi chahiye
what the parameter for synchronise of three drive with one potentiometer
Pulse input konsa hai isme
Sir please make video basic parameters of vfd gd20-or7g-bk-s2-bk, thanks
Thanx Deepak sharma for your comment. I think that the parameter mentioned in this video are same for the vfd you mention.
If have any queries please feel free to comment.
Thanx
Sir gd 10 ka aagrbatti mashin ka batadijeye plz
नमस्ते सर मुझे कुछ जानकारी चाहिए सर मैं आपको वीडियो भेज रहा हूं इसका कनेक्शन समझना है
मेरा नाम खालिद महमूद
What potentiometer do you use? thank you
AEK drive se dusra drive 10v deke synchronisation
Vala video banavo
Sir, Vfd ki training kaha hoti hai?
Sorry I don't show any traning available for vfd repairing.
Hello sir
Gd20 004 g 4
Potentiometer ke liy
P00.06-1 se nhi ho rha he sir
Display 0.00 bata raha hai
P00.06-0 se keypad se nhi ho rha
Display frequency show honi chahiy {exam. 50.00} vo nhi ho rhi he
Plz... Help me sir
Solar drives 50 HP ki rate bata dijiye aur Shriman apply dijiye aur mobile number
Sorry no idea for solar VFD rate.
Sir how to connect break system?
Push button se frequency up dawn ka parameters please
Very good sir
Thank you Sir 🙏
Good
How to connect reset button
S3 terminal default fault reset ke liye programm hota he agar apko dusre terminal ko programm Karna he to us terminal ke parameter me 7 dalne se fault reset ke liye programm ho Jayega..
No push button ka Connection com and s3 ke bich Karna padega..
@@niceelectronics9505 thanks for reply and proper understanding
Sir tell me how to reset password gd 20
P018 =1
Realy use ka video banavo bhai
Invt gd10 timing kaise set kare
P0.11. Acceleration Time
P0.12. Deceleration Time
Thanx.
अगर किसी invt drive का password किसी ने change किया हो तो उसे कैसे तोड़ेंगे
Sorry no idea about it..
Aap invt drive repair karte ho kiya two drive hai mere paas repair hona hai
Ap kahase ho..
Muje fix time base stop karna he
Sorry no function available for time base stop in vfd..Thanx
nice job
Pot synchronisation video
Why you do not make subtitles in English so other people could understadn
Try to explain it in English please.
Single phase output kaise le
Switch se run karaane ke liye parameter
Vfd time ke andar hi band ho jata hai
Bhai reverce nahi ho Rahi he
Nice sir
Pot se frq kam jayada Karo
Nice
Sir ji restore ka code
Hi sir
Sir aapke no do
Hi
P0.18 nmber 0 our 1
Español xf
In di
Sir ji Mara agarbatti machine na parameter set Karna hay invt gd20 hay please apka WhatsApp number dijiye
Invt 25 hp ki drive hai usme frequency varry nhi kr hi hai load badne per dc voltage down hoker moter trip ho jati hai aur Uu ka fault ata hai aur Pb group ki setting bhi nhi hai