RELAY SETTINGS AND CO ORDINATION|PART 1_PHASE FAULT|ELECTRICAL TECHNOLOGY AND INDUSTRIAL PRACTICE

Поделиться
HTML-код
  • Опубликовано: 16 янв 2025

Комментарии • 97

  • @VineethKumar-o5d
    @VineethKumar-o5d 2 месяца назад

    Very good illustration of relay co-ordination. Thanks for making this video.

  • @AminulIslam-we3kd
    @AminulIslam-we3kd 3 года назад +1

    Excellent explanation of relays, the most important protection devices

  • @soulofcinder2351
    @soulofcinder2351 2 года назад

    amazing work

  • @hassanmohammady9827
    @hassanmohammady9827 2 года назад

    It was really helpful and precise. Thanks a lot

  • @amitagrawal7383
    @amitagrawal7383 3 года назад

    Excellent brother. Good work. Thanks.

  • @Saharjunaid87
    @Saharjunaid87 4 года назад

    Amazing video

  • @chintanvaria2238
    @chintanvaria2238 5 лет назад +4

    Excellent explanation. Very clear and to the point. 1st video I have ever watched for such clear explanation about relay coordination on RUclips. Thank you. Keep making videos like this. 👍

  • @sohrabalmajose4082
    @sohrabalmajose4082 Год назад

    thank you very much on your video

  • @selvammurugaiah2074
    @selvammurugaiah2074 3 года назад

    Very informative.Good way of explanation.👍👏

  • @lovemybrothers727
    @lovemybrothers727 6 месяцев назад

    Great effort friend

  • @rezamagham4495
    @rezamagham4495 Год назад

    Perfect

  • @prashanthgaitonde3451
    @prashanthgaitonde3451 2 года назад

    best video on youtube

  • @vineshvinod4603
    @vineshvinod4603 4 года назад

    Great

  • @md.nazmussadat3263
    @md.nazmussadat3263 5 лет назад

    Great initiative. Please Continue 👌👌👌

  • @vineshvinod4603
    @vineshvinod4603 4 года назад

    Good class....need class for machines

  • @jayantkumardas1987
    @jayantkumardas1987 3 года назад

    Thank you so much

  • @shrutikaushik8086
    @shrutikaushik8086 5 лет назад +2

    Superb explanation , thanks a lot sir , please make more and more technical videos like this , it helps a lot

  • @fatjr.6287
    @fatjr.6287 5 лет назад

    Thank you for this, waiting for differential protection discussion from you sir.

  • @syedhajamuyinudeensaiyadya2960
    @syedhajamuyinudeensaiyadya2960 3 года назад

    👍👍👍

  • @shashankkumar7770
    @shashankkumar7770 4 года назад

    Thanku sir..

  • @shihabahmedalkatrani3050
    @shihabahmedalkatrani3050 5 лет назад

    Thank you very much

  • @rajeshparmar6944
    @rajeshparmar6944 Год назад

    Sir thx.one small query @about not clear if dot represents inrush current in tht case LV curve shown below dot is means tht LV ACB or relay operating lower than inrush or inrushblocking is used pl.clarify. Regards.

  • @durangi3716
    @durangi3716 5 лет назад

    Thank you very much!

  • @Vishal0106-m4p
    @Vishal0106-m4p 4 года назад

    Is this co-ordination good for numerical relays, since they have inrush protection in them

  • @Infiniteknowledgenikhilrathod
    @Infiniteknowledgenikhilrathod 3 года назад

    Which book due you referenced?

  • @sathaendi5224
    @sathaendi5224 4 года назад

    Hai can you explain about Synchronoscop...

  • @allthingsinonemedia3579
    @allthingsinonemedia3579 2 года назад

    Sir, would you gave me more information parallel transformer protection coordination in double bus-bar
    and also about protecting only selected transformer from the parallel one.
    Thanks for willingness

  • @adityatiwari8044
    @adityatiwari8044 4 года назад

    Sir I have an etap software but the basic problem is that in case of differential protection or in case of relay coordination it does not have an option of PS class CT please provide suggestions for this

  • @papakaaccountmummykaphone571
    @papakaaccountmummykaphone571 10 месяцев назад

    Sir,Pl make video on different IEC Characteristic and relay coordination using them

  • @BiswajitGhosh-gy1sc
    @BiswajitGhosh-gy1sc Год назад

    Please make a video of Battery sizing calculation by IEEE method.....

  • @gustavomarcelo7250
    @gustavomarcelo7250 Год назад

    Sir.
    What if the system is supplied by 2 parallel Tx?

  • @anwarhussainansari13
    @anwarhussainansari13 3 года назад

    Sir which book u follow ? Is this overcurrent protection scheme ?

  • @pemalhaden9268
    @pemalhaden9268 3 года назад

    Please can you show us how to do baseline data calculation for over current relay coordination in transmission line using software digsilent.

  • @g.r.akashprbhagar9927
    @g.r.akashprbhagar9927 9 месяцев назад

    Bro which software are you using for explaining this ?

  • @parthapratimnayak5791
    @parthapratimnayak5791 3 года назад

    Sir pl a video for ht industrial meter showing 02 nos kvar reading in secure premier e3m051 .pl clarify two reading parameter

  • @lokchand7962
    @lokchand7962 Год назад

    What is psm and tsm in numerical relay . i don't find that tipe of setting in numerical relay?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  Год назад

      PSM you need to calculate if you go by the hand calculation. Yes it is not an input setting to numerical relays. TsM is the time setting or time multiplier

    • @lokchand7962
      @lokchand7962 Год назад

      @@electricaltechnologyandind5335thank you very much for your response.😍😍

  • @imanrezaei8767
    @imanrezaei8767 4 года назад

    Thanks alot. How can i coordination o/c relays when 2 motors exist on LV busbar

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 года назад

      Motors are instantaneous or 0.05 second delayed. With breaker operating time it will be around 0.11 sec. Now co ordinate accordingly

    • @imanrezaei8767
      @imanrezaei8767 4 года назад

      Can i have your email sir due to sent network to you.i coordinated one network.could you please check it

  • @anwarhussainansari13
    @anwarhussainansari13 3 года назад

    Phase fault is same as Overcurrent ?

  • @nishananda9838
    @nishananda9838 4 года назад +1

    Thank you for vdo..
    I hv one question..How to select transformer withstand capacity?

    • @ShaileshKumarchetty
      @ShaileshKumarchetty 4 года назад

      As IEC 60076 (Standard for Transformer) withstand time is 2 sec for through fault.

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 года назад +1

      A trafo shall be capable to withstand for two second with one end short circuited and rated voltage applied at the other end

    • @ShaileshKumarchetty
      @ShaileshKumarchetty 4 года назад

      @@electricaltechnologyandind5335 good job, I liked your video. Quality content !

  • @pcselvam
    @pcselvam 4 года назад

    Very nice explanation sir......what about unbalance current in one phase... current circulate line CT? Trip?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 года назад +1

      If there is negetive sequence then you have to give elnegetive sequence relay, if earth fault then earth fault relay will trip

  • @josefinaiipolicarpio6647
    @josefinaiipolicarpio6647 4 года назад

    I see youre blogspot what you mean by B/C AND I/C and PCC, what does it stands for?

  • @Little_paaw
    @Little_paaw 5 лет назад

    Sir can you please make the video of how digital relay like schinder abb work? I have seen many time there is using logic gate how they help for working the relay?

  • @Moon3pell
    @Moon3pell 2 года назад

    Very good presentation. But the question is why 51(HV2) does not have any instantaneous element 50(HV2)? and only 50(HV1) has instantaneous?

  • @Nivupedia
    @Nivupedia 4 года назад

    Superb illustration, can you make video on Fault current calculation?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 года назад

      I will make. I am out of my home town. So dont have the set up. Hopefully from October end such videos will come

    • @Nivupedia
      @Nivupedia 4 года назад

      @@electricaltechnologyandind5335 Great 👍

  • @parthapratimnayak5791
    @parthapratimnayak5791 3 года назад

    Lt 3phase motor safety overload realy setting combination of thermal relay and electronics relay

  • @jameslee7004
    @jameslee7004 3 года назад

    Thank for your video. In the primary side, pickup current = 1.3x FLA, but secondary side, pickup current = 1.2 x FLA.. Is there any reason with two different value?

  • @saurabhlangave3528
    @saurabhlangave3528 5 лет назад

    Sir can u please suggest book for relay coordination for numerical relay ,As well as what type of protection we should provide for different types of electrical equipment .

  • @rengaramanujan
    @rengaramanujan 5 лет назад

    Could u please clarify the difference between 51G and 64R and please explain if the relay actuated which breaker I.e either hv to be trip or LV to be tripped

  • @khan_tanzeem0521
    @khan_tanzeem0521 4 года назад

    Excellent explanation..how can I calculate relay 67 / 67N and 32 if my load is 6MW can you please explain....I am looking for manual calculation without using software...voltage 4.16kV..

  • @jkj1459
    @jkj1459 4 года назад

    THANKS YOU SO MUCH SIR , HOW WE DEDUCE PSM FORMULA

  • @jameslee7004
    @jameslee7004 3 года назад

    Can you please show same topic using ETAP for next video if possible?

  • @manmohandhir9117
    @manmohandhir9117 Год назад

    Setting of 50 hv1 should be higher than secondary short ckt. reflecting on the primary. Setting at lower level will affect coordination

  • @shamirdebnath7407
    @shamirdebnath7407 4 года назад

    Good explanation but i have a question. when 2.5 MVA transfo switched on inrush current will flow. as 50(HV1) consider inrush, this will allow it. but 51( HV1) has lower limit of pick up current. Does this allow inrush current to flow?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 года назад

      51 will pickup but won't trip because inrush will be decreasing in nature. So the relay operating time will increase. And before tripping the inrush will be ended

  • @jimuelvillaoz4238
    @jimuelvillaoz4238 4 года назад

    Hi Sir, May I please know where exactly I can find the relay time selection as you mentioned in this video? Can you please provide me the specific link? Many thanks!

    • @jimuelvillaoz4238
      @jimuelvillaoz4238 4 года назад +1

      I am really hoping that you will notice my post the soonest and get a feed back on this. Many thanks!

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 года назад +1

      The relay timing I explained is my experience and some calculation regarding the fault withstand capability of bus bar, cables, transformer etc.

  • @adelino19701
    @adelino19701 4 года назад

    My question is why in setting of 51(HV2) the short circuit fault current is considered?. I understand that ansi code 51 is for phase time overcurrent and ansi code 50 is instantaneous overcurrent. Therefore such short circuit fault current should be considered in setiing of 50 (HV1) and not 51(HV2)

  • @prabhaamjmurali8379
    @prabhaamjmurali8379 4 года назад +1

    Thanks for the video. Very clear explanation. Can you make video for directional over current with 2 sources??

  • @Liguritio
    @Liguritio 28 дней назад

    Why no 50 HV2 function ?

  • @aliamoor1541
    @aliamoor1541 5 лет назад

    thank you sir : the equipements of electrical power system are transformer , medium voltage cable , bus bar and motor electric so we have different zones of protection in our electrical system and we must be provided by relays according to type of défaut electric my question is how to choose type of relay (50/51) and its calculations

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 лет назад +1

      calculation of 50 and 51 is already there.. you can watch it

    • @aliamoor1541
      @aliamoor1541 5 лет назад

      Thanks a lot sir when we use IDMT relay or instantaneous relay or both in different zone of electrical system

  • @surendranram4364
    @surendranram4364 4 года назад

    at 9.25 seconds setting for 51LV you calculated sec. current without pf. why? then why restricted and differential relay is not part of coordination?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 года назад

      Transformer is rated in kva. So how power factor will come in picture??? Restricted earth fault relay is instantaneous relay, special type of protection...

  • @97542729
    @97542729 Год назад

    What are difference relay cordnetion between 400/200/132/33 KV Substation to 33/11kv substation earth fault over current Numerical relay cordnetion please suggest me

  • @kiagengreksapati
    @kiagengreksapati 4 года назад +1

    I offer to addmit translate or english subtitle on this video, that will be very helping.

  • @ats3389
    @ats3389 5 лет назад

    Sir,A minor mistake is there in full load current calculation .. the values are correct but the formula is given like this Power/√3 /voltage....It should be like this Power/√3*voltage

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 лет назад

      you are also wrong.... it is power/(√3*voltage).
      i hope you have understood the difference, and why the values have been correct....

    • @ats3389
      @ats3389 5 лет назад

      @@electricaltechnologyandind5335 yes sir i am also wrong. sorry

  • @narayanaswamygunasekaran521
    @narayanaswamygunasekaran521 4 года назад

    Font size may be increased not readable or video may be done in more close up position

  • @bongbengsiong5545
    @bongbengsiong5545 5 лет назад +1

    sir, I love u

  • @anilchopra83
    @anilchopra83 4 года назад

    thanks but audio quality not good

  • @nduduzozondi8953
    @nduduzozondi8953 5 лет назад

    Thank you for this content. Can you please make a video on Mini substation, Kiosk and electrification

  • @pcselvam
    @pcselvam 4 года назад

    Pl reply sir......

  • @Invisionmedibihar
    @Invisionmedibihar 3 года назад

    sir can you explane in hindi

  • @ahmadrazarizvi7819
    @ahmadrazarizvi7819 4 месяца назад

    Noise issue

  • @albertos8809
    @albertos8809 4 года назад

    Subtitles please I can't understand because of the accent

  • @dilipsahusahu680
    @dilipsahusahu680 5 лет назад

    Hindi