How to identify what heating system you have. In the UK.

Поделиться
HTML-код
  • Опубликовано: 26 сен 2024

Комментарии • 157

  • @sukmangat
    @sukmangat 3 года назад +6

    Very helpful video, cheers derek for taking the time to explain the various boiler systems, legend !!!

    • @dereton33
      @dereton33  3 года назад

      Glad to help

    • @Rectangle101
      @Rectangle101 2 года назад

      @@dereton33 instead of pointing the camera at your monitor have a look into OBS its a screen capture software check youtube for tutorials for better quality clips hope this helps

  • @nimasala8764
    @nimasala8764 6 лет назад +2

    You are remarkable, absolutely with kind and humble

  • @JodyLeeSchroeder
    @JodyLeeSchroeder 3 года назад

    you legend ! almost no vids on this stuff , it gave me a big help sir , thank you

  • @twinkletoes4236
    @twinkletoes4236 5 лет назад +2

    Can I just say that I will not know it when I see it because I'm not a plumber, thanks for making this though mostly very informative

  • @Ilovetosingem
    @Ilovetosingem 2 года назад

    Thanks Del all the very best to you and yours.

  • @Bilal-wj7bh
    @Bilal-wj7bh Год назад

    This is one of the best videos

    • @dereton33
      @dereton33  Год назад

      Thank you great comments indeed.

  • @yu-iw2pw
    @yu-iw2pw 2 года назад +1

    great video, why some cylinder with 5 pipe ? I know 1 cold in 1hot out , and 2 in and out from boiler , and no idea what extra pipe for ?

    • @dereton33
      @dereton33  2 года назад

      A hot return for extra long trips to hot taps.

  • @showme360
    @showme360 6 лет назад

    Excellent Vid mate will keep you in mind when I get to modify my system!

  • @denissbogdanovs7926
    @denissbogdanovs7926 6 лет назад

    Great video for new starters. Thanks

  • @elenakritikos
    @elenakritikos 3 года назад

    Thanks this was really helpful!

  • @nickcollins7568
    @nickcollins7568 7 лет назад

    Another one to add to the list. The single feed primatic hot water cylinder, using just an airlock to separate the radiator water from that which comes out of the tap. If one can't find a vented feed and expansion cistern at the top of the system or a pressure vessel one could be unfortunate enough to have a primatic cylinder

    • @dereton33
      @dereton33  7 лет назад +2

      Thanks Nick, I remember those, fortunately they are rare these days.

  • @georgehaddad1159
    @georgehaddad1159 Месяц назад

    Thanks for the great explanation. I have an F&E system, but only seem to have 1 motorised valve in my airing cupboard. I thought traditionally there would be 2 (one for heating and one for hot water) why do I only have 1 motorised valve? I'm looking at installing a Google nest and wanted to be able to control hot water and heating separately from my smart phone. So in winter when I'm out I can switch on the heating 15 mins before I get home. Any hints or tips you can provide would be great as I'm trying to figure out if I have an S plan or Y plan configuration

    • @dereton33
      @dereton33  Месяц назад +1

      You have one motorised valve as it is a three way valve controlling hot water and heating. You have a Y plan.

  • @luckyeddie4454
    @luckyeddie4454 8 лет назад

    Thanks for the reply, a bit obvious reallywhen you think about it ...... I didn't, each to their own as the saying goes thanks again.

  • @charliefox6987
    @charliefox6987 3 года назад

    Fantastic video thanks

  • @Habib_Ur_Rehman_
    @Habib_Ur_Rehman_ 10 месяцев назад

    Hello, thank you for the video. I have question please. Q. How do I identify if I have single or a double pipe system that goes to the radiator please.

    • @dereton33
      @dereton33  10 месяцев назад +1

      On a single pipe system just one pipe will feed in one side of the radiator, then pass underneath and feed the other side.

  • @StephenLyons1984
    @StephenLyons1984 8 лет назад

    another good video thank you. im a diy guy find these great, helped me out once or twice

    • @dereton33
      @dereton33  8 лет назад

      +Stephen Lyons No problem pleased to help.

  • @antonymurray1976
    @antonymurray1976 4 года назад

    excellent video

    • @dereton33
      @dereton33  4 года назад

      Thank you very much!

  • @johnanthony6214
    @johnanthony6214 6 лет назад

    Very helpfull well explained thanks

  • @ro63rto
    @ro63rto 8 лет назад

    Thanks for this.
    Confirms I have the second system. Some muppet decided to run the overflow from the small tank into the big one :-O
    One thing I can't find is any motorised valves. Got a pump right next to the boiler in the garage but I cannot find any motorised valves. Trying to diagnose why the boiler switches in then off when the hot water timer kicks in.

  • @FighterPilot1945
    @FighterPilot1945 2 года назад

    Thanks very informative helpful..

  • @frankw9836
    @frankw9836 2 года назад

    i moved into an old house with an open fireplace. I've been told there is a "back boiler" which heats the water and radiators when the fire is lit . There is a switch which apparently pumps the hot water into the radiators ? The fire is lit i switch on the pump (i can hear bubbling noise) but no warm radiators or hot water . Can someone explain, why not ?

    • @dereton33
      @dereton33  2 года назад +1

      Check the small header tank in the loft. (F and E tank) It could well be empty. if it is ok then you have air in the system.

  • @OneAajis
    @OneAajis 6 лет назад

    Well explained thanks.

  • @sarahh9186
    @sarahh9186 Год назад

    Hi Al, Another great Video!
    I hope you can help me with a problem we have with our shower? When we are using the shower if someone flushes the toilet the water in the shower gets very hot, it’s the same if someone uses the cold tap on the basin. In turn if we turn on the hot tap on the basin the shower is freezing cold. We checked this yesterday and not sure if we can do anything. From your videos we have worked out we have a gravity feed system. Thanks very much

    • @dereton33
      @dereton33  Год назад

      Nothing can be done with gravity, your only option would be to use a shower pump.

  • @Peter1Europe
    @Peter1Europe Год назад

    Why I have to refill tank upstairs every third day ? Where the water disappear ?

    • @dereton33
      @dereton33  Год назад

      If you mean the F and E tank then it means the ball valve is jammed off.

  • @DrBroncanuus
    @DrBroncanuus 5 лет назад +1

    hi Derek, I've got a regular boiler, with large tank plus small tank in loft...my Hot water cyclinder is under boiler in airing cupboard...but how do I tell if my Hot Water cyclinder is Indirect or Direct ?

    • @dereton33
      @dereton33  5 лет назад +1

      You have an F and E tank so yours is indirect.

  • @ministry_of_love
    @ministry_of_love 2 года назад

    Pressure Vessel System 2:14

  • @abiegreyvenstein5427
    @abiegreyvenstein5427 2 года назад

    So, when I look at my heaters, how do I identify my system?

    • @dereton33
      @dereton33  2 года назад

      Combi boiler has no hot water tank or roof tanks. F and E does.

  • @layton7430
    @layton7430 7 лет назад

    excellent information and very well put, thank you, I have a question what system would I have to use to heat my water and raditors via a wood burning stove boiler? is it vented or unvented? thank you

  • @petinyiri
    @petinyiri Год назад

    our system have a small water tank in the loft, and downstairs, I see a small vessel just above the hot water cylinder but I dont see a pressure gauge anywhere, how do i know what system do we have.? as we need to replace the motorised zone valve.
    advice?

    • @dereton33
      @dereton33  Год назад

      As you have no pressure gauge and still have a roof tank I would say you have an F and E system.. It would not effect changing the motorised valve.

    • @petinyiri
      @petinyiri Год назад

      @@dereton33 thanks, do i will need to drain it fully? the pump and the motorised valve is located in the loft were the boiler and hot water cylinder is in the bungalow

  • @markthompson8511
    @markthompson8511 5 лет назад

    Hi great videos can I magnaclense a prismatic system ? Also on other systems do I need to isolate the heating coils ? Thanks for any help you can share

  • @andrewedwards7880
    @andrewedwards7880 Год назад

    Great video - thanks for sharing, can you tell me, if I have an unvented system as per 3min 25s of your video - to increase my hot water pressure, do I fit a mains booster on the cold feed into the tank, or on the hot outlet side?

  • @tk4270
    @tk4270 2 года назад

    I have two overhead black plastic tanks as part of our open vent system. I need to add radiator cleaner. Which one do i put it in. They both appear same size.

    • @dereton33
      @dereton33  2 года назад +1

      The F and E one it should be slightly smaller than your main tank and also will have brown sludgy water in it.

  • @darrenturner1119
    @darrenturner1119 2 года назад

    Great Vid pal, Not sure if you can help, I currently have a bosch cdi boiler Not combi with a hot water cylinder, for some reason I'm not getting hot water, we have the timer on advance and the boiler isn't firing up,I've also tried to switch the emersion on and the cylinder isn't getting hot, my theory was the thermostat but not 100%, surely the thermostat doesn't control both the boiler and the electrical element or does it ? as this would make sense that the thermostat is dead, any pointers would be great

    • @dereton33
      @dereton33  2 года назад

      It will be themotorised valve. Switch over to manual for now.

  • @luckyeddie4454
    @luckyeddie4454 8 лет назад

    Another good video very informative thanks. I have a question, is the flow, hot feed, always on the left side of the radiator or does it depend on who installed the system?

    • @dereton33
      @dereton33  8 лет назад +1

      +luckyeddie Depends who installed the system. The way to find out is to switch the heating on from cold and see which pipe heats up first coz that one will be the flow.

  • @maksymtrofimenko7325
    @maksymtrofimenko7325 Год назад

    A humming pump in the middle of the house is very common and terrible!

  • @rogermarkendale5404
    @rogermarkendale5404 3 года назад

    Hi can I put leak sealer in the water tank in the loft. My boiler is behind the fire downstair. The hot water supplies the central heating aswell as taps, shower etc. Would the sealer block the shower thanks

    • @dereton33
      @dereton33  3 года назад

      No it will be alright. Put it in the F and E tank, then drain about a bucket full of water from the system downstairs so the stuff gets well into the system.

  • @BarriosGroupie
    @BarriosGroupie 5 лет назад +1

    What about series connection of radiators in a combi system?

  • @malcolmdonbavand9589
    @malcolmdonbavand9589 3 года назад

    Does an old primatic system leave you open t legionnaires as I have only one tank in the loft system is 25 yrs old or more 🙏

    • @dereton33
      @dereton33  3 года назад

      No , they last years , scaremongering know-alls spread worries and fears, like the petrol shortage.

  • @mrb9830
    @mrb9830 2 года назад

    Thanks for the video! How do you determine if a combination boiler is sufficient or if you need a cylinder (of some sort). Planning to extend to have 3 bathrooms. Will an unvented system prevent filling of a bath or a toilet flushing affecting a shower? Thanks!

    • @dereton33
      @dereton33  2 года назад +1

      I would stick with the Combi. it will not effect the filling of a bath or a shower operating too much. A cylinder will never cope.

  • @davidclarke4040
    @davidclarke4040 8 лет назад

    hi thank for a good video nice tips

    • @dereton33
      @dereton33  8 лет назад

      +david clarke Cheers Dave.

  • @artursmihalonoks4189
    @artursmihalonoks4189 3 года назад

    whats the purpose of small pipe outside of the house? i mean,when when i switch on heating system,it heats up and when its heats up,outside of house i have small black pipe.and from there dripps water.why?

  • @HappyLightning-jv5vs
    @HappyLightning-jv5vs 8 месяцев назад

    Hi Derek, thanks !)lfor the education, 😊 I NEED YOUR HELP Trying tonfigure out what type of heating system I have, what kind of boiler, ive left as muxh info as I can below and I know I have no right ask you for anything but Google let downand I'm unsure who to go to,. I &ope I hear from you.
    First. An unqualified techncian Guessed it was A "System Boiler" but does that mean Conventional boiler?? He diddnt know either.
    I live in a Bungalow, and in my hallway (or first small room you enter from the front door that has a door to the living room on the left and bathroom to the right) in betwee, theires another door with t&e airing cupboard, I have a reservoir that's slightly raised by about 6 inches, and the reservoir (if this the right term) has a dial on it to control the hot water temperature (using a flathead screw driver), right above it (Above the towels there is a unit that tells me the water pressure, if if the dial drops I just need to stick a flathead into something near the pressure gauge and turn until its back to normal, there's also a switch in the airing cupboard that shuts off the hot water (if that helps, my "thermometer" is an old dial that clicks on when turned by hand, this is in the living room,
    In the kitchen at the back of the bungalow (it's a really small bungalow) youl find what I believe is called the programmer, it's a pixilated screen that tela the time and i can use it to schedule when I want My heating on, or if I want to turn my hot water off all night then heat it up an hour or so before waking up so it's warm by the time I get my morning wash.
    The things I have mentione# so far! Are all 1 brand, "Honeywell" however next to my programmer is my (forgot the name) heating system Specifically an Ideal: Logic - Heat 15.
    Clearly I am clueless with these systems right now but I'm trying to learn.
    My equipment is outdated and I was hoping to upgrade, my thermostat is that old that the numbers have faded, it doesn't click on until I dial it past 30C, so I was hoping I could change the thermostat (my brother installed his own system as he's qualified so il ask him to do mine, he told me to find out what kind of heating ststem I have first, i have 5 radiators (1 for each room)
    And I was hoping I could install the honeywell T6 Thermostat or similar along with those things that you somehow screw onto your radiator and using an app you can set b off times or control the temperature properly, and most importantly Save money, I can get the honeywell t6 (and all it comes with + 3 radiator valves? If that's the right word) and have them fitted, it does mean giving him my old PC (that I don't use) but if it can save me money in the long run then I'm happy,.
    So if possible, can you tell me what type of boiler? System I have?
    Yesterday my pressure dropped so I had to call the housing company (I diddnt know about the
    Valve you can turn with a flathead to fix the issue back then ) but I asled him and he said
    "I've only been here a
    Week, they only send me on the small jobs I'm still learning but I'd say it's a "system boiler"
    Is that right? And I can't find anything about them, unless it' another word for Conventional??
    I'm so sorry to take up so much of your time, Google isnt helping and I don't know what to search for,.
    Anyway I'm sorry for the long message I wasn't sure what info you needed so I'm sorry if went to far and I hope you know that il support you/subscribe whether or not you reply, and I understand if you don't reply, my own fault for looking like a psychopath hahaha
    Take Care Derek, Stay safe & I hope 2024 brings you all those well deserved memories and dreams we both know you deserve, including your following/Subscribers going sky high😊
    SORRY AGAIN. Take care
    Chris

    • @dereton33
      @dereton33  8 месяцев назад

      Hi Chris, You have a pressurised system, so you may well have a combi boiler. If however you have a hot water cylinder then you have a System boiler. You can also tell if you have a red pressure vessel mounted somewhere. You can change the thermostat for almost any type. Also as you say you can get the smart radiator TRVs.

  • @garyashurst1452
    @garyashurst1452 3 года назад

    Hi, I have a f & e system, I am removing the bath tomorrow and need to drain down the water to the bath. Do I need to isolate the large water tank in the loft to do this? Thank you

    • @dereton33
      @dereton33  3 года назад +1

      Safest bet as most gate valves never shut off properly.

  • @ifonly.4063
    @ifonly.4063 3 года назад

    01:40 ….novice here, my tank has just started leaking at the top around the base of the silver circular thingy ma jiggy. What do I do apart from scream ?

  • @1blondied
    @1blondied 2 года назад

    Can the loft tanks ever become empty then need time to fill again ?

    • @dereton33
      @dereton33  2 года назад +1

      Yes if you run a bath or the valve runs slow in the tank.

    • @1blondied
      @1blondied 2 года назад

      @@dereton33 ... that's what's happened then ...we've hardly got water comming out of taps...my daughter's boyfriend had a 15 min shower but he wasn't to know we have a loft tank lol...Thankyou x

  • @markmenow2day
    @markmenow2day 6 лет назад +1

    hi, how do i stop hot water coming through the taps from a cylinder to adjust pipework in the bathroom, and do i have to switch anything off while cutting pipework, thanks

    • @dereton33
      @dereton33  6 лет назад +1

      There should be a gate valve in the airing cupboard. If not shut off the mains and drain the roof tank. Switch the boiler off.

    • @markmenow2day
      @markmenow2day 6 лет назад

      i need to cut the hot water tap pipes, so do i have to drain the cylinder down to do this ? thanks mark, or is there an easier way of stoping the hot water coming through the taps to cut the pipes, thanks again, mark.

    • @markmenow2day
      @markmenow2day 6 лет назад

      i have to drain the boiler though dont i ?, and if it an indirect system and the radiators are rn through it wont that drain the radiators ?, sorry for being so ignorant about these things.

  • @parisrockclubschoolenterta3798
    @parisrockclubschoolenterta3798 6 лет назад

    Have got a filling loop pressure vessel (sort not to sure how you spell it) the question is why my hot water from my tank is warm but never hot? The central heat work well and very hot.
    When i plug separately the water tank water is very hot no problem.

    • @dereton33
      @dereton33  6 лет назад

      Could be quite a few things, first check the motorised valve.

    • @parisrockclubschoolenterta3798
      @parisrockclubschoolenterta3798 6 лет назад

      Its now working fine as i discover the wire as been cut which command the valve

  • @hannahkaur8450
    @hannahkaur8450 2 года назад

    Hi I have an ideal icos he15 boiler but I can't work out if it is a regular conventional boiler or if it is a system boiler. I have a hot water cyclinder and it looks like a big red balloon type thing in it maybe fe cyclinder? I don't have any water tank in the loft. I can't work out to replace with a new system boiler or regular boiler. I believe I have a 'closed' system as I don't have an extra cold water tank in loft. I can still obtain hot water from the cyclinder even though my boiler is broken.

    • @dereton33
      @dereton33  2 года назад +1

      You have a sealed system with a pressure vessel. You more than likely have low pressure (below half a bar) or have a broken 3 or 2 way valve.

    • @hannahkaur8450
      @hannahkaur8450 2 года назад

      Yep low pressure but boiler is 13 years old and is costing a lot to repair the 'motherboard' great thanks for your prompt response, system boiler it is 👍

  • @m0gga
    @m0gga 6 лет назад

    Great video, thanks for sharing your knowledge. I have a question if you don't mind. In a typical F and E system what would be the most likely cause of the expansion tank filling up with hot water? Thanks.

    • @dereton33
      @dereton33  6 лет назад

      The inner coil of the hot water cylinder is holed.

    • @FighterPilot1945
      @FighterPilot1945 2 года назад

      My friends pump was set by plumber to max speed,I turned down to lowest speed cured this problem.

  • @steveprice9462
    @steveprice9462 2 года назад

    Hi Al, really useful video but I'm still a bit confused. My system is like the third picture you show in this video which I am assuming, from what you say, is NOT a combi boiler. So, 2 questions if I may. Is the third picture a combi boiler and if not would I use the same techniques to reduce its pressure as one would for a combi boiler. Many thanks. Steve.

    • @dereton33
      @dereton33  2 года назад

      The 3rd picture is a F and E system that uses a pressure vessel. As you have a pressure vessel fitted with gauge you use the same way of reducing the pressure as if you had a combi boiler..

    • @steveprice9462
      @steveprice9462 2 года назад

      @@dereton33 Hi Al, sorry, I made a mistake. I meant to say my boiler is picture no. 4, not 3. My old house had an F&E system and I'm a bit unsure of this unfamiliar one in my current house a Potterton condensing boiler(your pic. no 4). Do I still use the same techniques to reduce pressure? Thanks Again.

  • @sexysnake6192
    @sexysnake6192 6 лет назад

    If a boiler make loud noise n a 3 flat n no heat coming up at all is this something 2 be affaird of

    • @dereton33
      @dereton33  6 лет назад

      No the boiler has safety features built in, but it should be looked at by a professional gas engineer sooner rather than later.

  • @jasonmcloughlin1830
    @jasonmcloughlin1830 6 лет назад

    Hi I have a oil burner to heat my radiators, downstairs is hot and upstairs is cold my water was off for a few days and I think this let air into the system! How can I get the radiator upstairs hot again, please help! ,!

    • @dereton33
      @dereton33  6 лет назад

      Try turning off all the downstairs ones to force it upstairs, do check there is no air in the rads upstairs first.

  • @MontyVideo969
    @MontyVideo969 6 лет назад

    Hi - Really useful video. Thanks. One question though. We are about to replace our 4-pipe regular oil boiler (20 years old) with a gas condensing boiler; is there any reason to stop us doing, pretty much, a straight swap-out in terms of the 4 pipes from the old boiler in the garage and what other components might we need to buy.

    • @dereton33
      @dereton33  6 лет назад

      No should be straight forward swap. You will need to run an extra condensing pipe into a drain, and a gas supply pipe 22 mm.

    • @MontyVideo969
      @MontyVideo969 6 лет назад

      Thanks for the super quick response. One local company we had quote for the work wanted to rip out the old h/w cylinder from our airing cupboard, rip out the Header and Expansion tanks, supply a new h/w cylinder in the garage, supply/fit a new pump, supply fit a divertor (I guess they have to because our existing system is 4-pipe), fit a new wired programmer in the cellar, have a wireless room stat, fit a wiring centre box and re-do all the pipework! I guess they're just trying to make more work (=money) for themselves. Who can one trust nowadays? We already have all of that apart from the divertor of course (£60). So it will be interesting/laughable(?) to see what the quote is.

    • @dereton33
      @dereton33  6 лет назад

      Wow, that`s one way to give the bill a massive boost.

  • @brzuchol84
    @brzuchol84 6 лет назад

    Hi, thanks for the video! It looks like I have a combi system. Can I add a thermostat to it and how much this cost rughtly? I have a boiler - saunier duval themaclassic f24e.

    • @dereton33
      @dereton33  6 лет назад +1

      Yes you can add a thermostat. Do not know about the cost of fitting but they cost about £30.00 to buy.

  • @noureddine309
    @noureddine309 7 лет назад +3

    Top man. Great video. Many thanks.

  • @buriencox
    @buriencox 8 лет назад

    Cheers for that vid! I have a question about three port valves. The motor head on mine keeps clicking between centre and hot water. It won't settle and continually clicks. It's driving me bananas! Any idea what might be going wrong? It is a Drayton.

    • @dereton33
      @dereton33  8 лет назад

      +burien cox Hate to say it but looks like a faulty valve.

  • @alfiedog2942
    @alfiedog2942 4 года назад

    Hi, we have f and e system, the small heating header tank water level has dropped after I have turned water supply to it , does this definitely mean we have a leak in the central heating somewhere? Currently having issues with leaks in copper pipe in. 30 years old house 🥴

    • @dereton33
      @dereton33  4 года назад +1

      Try tying the valve up for a few days then see how much loss there is. If the tank is empty then yes a leak if not much has gone, then no.

    • @alfiedog2942
      @alfiedog2942 4 года назад

      dereton33 thanks I’d had it tied up for 2 days and about 3 or 4 inches had dropped but not empty, I will tie up again and leave for longer and keep an eye on it

    • @alfiedog2942
      @alfiedog2942 4 года назад

      dereton33 hi I’ve now had the valve closed for a week and the level has dropped 15mm is this a concern? The tank has been uncovered so I suppose with the heat it is possible of some evaporation ? Thanks

  • @helenhanson5781
    @helenhanson5781 6 лет назад

    Housing Association installed Vaillant boiler years ago, (replaced Immersion) Im sure a cold water loft tank still feeds bathroom , is this usual?, is it good or bad?health/performance/energy wise?. Is it legal? Nobody has cleaned/checked tank for many years, dont think it even has a lid. Thanks ; )

    • @dereton33
      @dereton33  6 лет назад

      Yes it is still quite legal and as long as you do not drink from the basin tap you will be ok. Health wise I can only say that as far as I know it has done no harm so far.

  • @herobo123456
    @herobo123456 7 лет назад

    whats F and E system 1:27 ? Tought there is just direct and indirect systems

    • @dereton33
      @dereton33  7 лет назад +4

      F is feed E is expansion. There are also direct and indirect systems.

    • @herobo123456
      @herobo123456 7 лет назад

      cheers

  • @makolic1
    @makolic1 7 лет назад

    why do you call it an f and e system ?

    • @dereton33
      @dereton33  7 лет назад +2

      Its short for feed and expansion system.

  • @shafserious2805
    @shafserious2805 4 года назад

    You again😉

  • @parisrockclubschoolenterta3798
    @parisrockclubschoolenterta3798 7 лет назад +1

    Hi, again i have a feeling loop system with pressure vessel. At present i use only the Hot from the tank which as been connected to the electricity.
    I have switch off the comby and switch on the tank water only. The water is too hot! i have turn down the Honeywell temperature gage but with no effect what so ever.
    I would like to use only the hot on the hot water tap with reasonable hot water. Any suggestion? Thank you,

    • @dereton33
      @dereton33  7 лет назад

      +Jean Leclerc you will need to turn down the thermostat in the immersion heater.

    • @parisrockclubschoolenterta3798
      @parisrockclubschoolenterta3798 7 лет назад

      Ok i will check that tomorrow thank you. you are so helpful.

    • @cater4anytink45
      @cater4anytink45 5 лет назад

      Same problem as me but my water is really hot...sure its gonna be thermostat's broken,sometimes they seize onto the copper tank so I'm already expecting a bill

  • @bencb3
    @bencb3 8 лет назад +2

    hi, whenever I put my heating on I get this horrible smell. It is a mix of a mouldy, gas smell and it always happens in the morning. any ideas what it could be?

    • @dereton33
      @dereton33  8 лет назад

      +bencb3 No but I would get the boiler checked.

    • @colincowell6833
      @colincowell6833 8 лет назад

      Hi, I had a similar problem first thing in the morning in the bathroom,a gassy /cabbage smell,turned out to be a dead dried mouse under the bathroom floor that had died next to the rad pipe.

    • @manofkentcatapultsgunsando5069
      @manofkentcatapultsgunsando5069 6 лет назад +1

      dereton33 Your the man.

    • @Novel_clips
      @Novel_clips 5 лет назад

      my boilers enginers name is aah

    • @1700iDiGuy
      @1700iDiGuy 5 лет назад +1

      bencb3 last time i had that it turned out to be my gf’s farts.

  • @ursamajor6546
    @ursamajor6546 6 лет назад +1

    F and E???

    • @dereton33
      @dereton33  6 лет назад

      Feed and Expansion.

    • @azizuk6720
      @azizuk6720 5 лет назад

      Ursa Major65 Feed and expansion and it is 81 L

  • @HeavyMetalRuinedMyLife1971a
    @HeavyMetalRuinedMyLife1971a 5 лет назад

    Scottish rite widows son? 😉 Wink wink

  • @johnmcentegart007
    @johnmcentegart007 22 дня назад

    This is the most common system in the Southern United States. Delighted to see the British copying everything.

    • @dereton33
      @dereton33  22 дня назад

      We always follow our American cousins.

    • @johnmcentegart007
      @johnmcentegart007 18 дней назад

      @@dereton33 American cousins my butt. You would swear that the British single-handedly populated the United States. The biggest ethnic groups in the United States are Irish/German/Italian. The British were forcefully made to leave the North American continent in the American revolutionary war

  • @djtomcass2668
    @djtomcass2668 2 года назад

    I have gas and want to fit and electric shower above bath. Both sink and bath pipes are fed of 15mm then 15 to 22mm flexi under bath. Do i take feed from under the sink or under the bath? Thanks

    • @dereton33
      @dereton33  2 года назад

      It does not matter which as long as they are both mains.

    • @djtomcass2668
      @djtomcass2668 2 года назад

      @@dereton33 thanks for your reply, how do i determine what is mains?

  • @natashamckenzie896
    @natashamckenzie896 7 лет назад

    So.. I have a cold water tank - upstairs in the loft - I think we have figured that it feeds the upstairs so bath, sink and toilet. But I also have a combi boiler which by all accounts looks like its on the mains.
    Do I still need the tank? It makes fro convoluted processes when trying to isolate water!

    • @dereton33
      @dereton33  7 лет назад +2

      The cold water tank is probably feeding the cold bath/basin taps and WC cistern. I have a video on getting more pressure which shows how to convert to mains. You could then loose the tank in the loft.

    • @wheelq84
      @wheelq84 3 года назад

      @@dereton33 But if there was enough pressure to fill up the tank, then why was it installed there in the first place? Currently I'm thinking about removing the tank and connecting the inlet to the tank with the outlet from the tank. Will this be a problem?