How to De-embed an S-parameter File From a VNA Measurement

Поделиться
HTML-код
  • Опубликовано: 9 ноя 2024

Комментарии • 4

  • @strato1917
    @strato1917 4 года назад

    Nice video Brian! Look forward to seeing another video for discussions on the s-parameter diagrams on the board behind!

    • @virtualparticles
      @virtualparticles 4 года назад

      Thanks! I should do something on calibration terms soon. That should be interesting.

  • @aghilesdjelouahi374
    @aghilesdjelouahi374 4 года назад

    hello,
    thanks for your vedeo .
    I want to measure periability of a palastic, so I use Transmission/Reflection Line method, with a VNA and a waveguide. I want to de-embedd my measurement, but I don't know if your method is applicable to my measurement or not.

    • @virtualparticles
      @virtualparticles 4 года назад

      Hi Aghiles. In this case, I would just do a regular TRL calibration such that the reference plane is right at the surface of the plastic material.