Daikin L5 Error. Daikin L5 Error indicates an outdoor unit inverter compressor over current fault. This happens when there is excessive current pulled through the transistor module, which can be caused from the compressor seizing or possibly going to earth, this has to be checked with a megger meter. It may also be possible that the inverter PCB is at fault, this can be checked using an inverter checker. In this case, the inverter PCB was at fault. I always replace the outdoor fan motor at the same time whether it's faulty or not.
@@cebuairconservices2224 boss magandang araw sayo tanong ko lang L5 din ang error tinangal ko na din yong connection ng airswing motor na mamatay padin every 1 to 2 hours tapos hindi na mg ON mg blink2 na kailangan pang e reset ang breaker tapos na mamatay na naman every 1 to 2 hrs ano kaya prblema?
Daikin L5 Error.
Daikin L5 Error indicates an outdoor unit inverter compressor over current fault. This happens when there is excessive current pulled through the transistor module, which can be caused from the compressor seizing or possibly going to earth, this has to be checked with a megger meter.
It may also be possible that the inverter PCB is at fault, this can be checked using an inverter checker.
In this case, the inverter PCB was at fault. I always replace the outdoor fan motor at the same time whether it's faulty or not.
Ac technician po ba kayo sir
Google pa more🤣
Dami mo sinasabi, usually sa L5 is airswing motor lang tsk🤣
buti tinisting kc kung hindi sisisihin ka ng customer
Klaro kaayo sa tingog ikaw lage ni Bai Ricky👍
Sakpan da hehe
Good job master Ricky!
Salamat master
Master pano pag wala namn error code pero ayaw gumana? Swing gumagana tapos namamatay din di gumagana fan motor nag blink sya
@@vinceadamreyes4628 EVRY 5 MIINS BA NAMAMATAY CONDENSER MASTER?
@@cebuairconservices2224 boss magandang araw sayo tanong ko lang L5 din ang error tinangal ko na din yong connection ng airswing motor na mamatay padin every 1 to 2 hours tapos hindi na mg ON mg blink2 na kailangan pang e reset ang breaker tapos na mamatay na naman every 1 to 2 hrs ano kaya prblema?
@@gibsontaneca6489 sir ok na ba aircon mo?ano naging sira?parehas kasi tayo problem
good one paps pwede kong masubokan yan sa isang unit
Hehehe nagreset Ka Lang master Kahit ikabit mo uli ung swing talagang gagana Yan hehehe peace
Ano po kaya dahilan.. Ayaw mag on ng blink ng aircon nmn
L5 means outdoor fan motor defective
Ang layo ng sagot mo paps
Out door main board boss
nag reset ka lng naman boss .. . .mag biblink pa rin yan
IPM error L5
Hahaha. Over current yan sa out put
ada yg bhs indonesia??? ac saya sama percis begini
Lol..alamin mo ano ibig sabihin ng l5 error ng daikin