    @luisburds4251 2 года назад +6

    Daikin L5 Error.
    Daikin L5 Error indicates an outdoor unit inverter compressor over current fault. This happens when there is excessive current pulled through the transistor module, which can be caused from the compressor seizing or possibly going to earth, this has to be checked with a megger meter.
    It may also be possible that the inverter PCB is at fault, this can be checked using an inverter checker.
    In this case, the inverter PCB was at fault. I always replace the outdoor fan motor at the same time whether it's faulty or not.

    • @jpro1810
      @jpro1810 2 года назад

      Ac technician po ba kayo sir

    • @arjiedultra7360
      @arjiedultra7360 2 года назад

      Google pa more🤣

    • @arjiedultra7360
      @arjiedultra7360 2 года назад +1

      Dami mo sinasabi, usually sa L5 is airswing motor lang tsk🤣

  • @darwinbinza8218
    @darwinbinza8218 7 дней назад

    buti tinisting kc kung hindi sisisihin ka ng customer

  • @alfiegeromo6371
    @alfiegeromo6371 2 года назад +1

    Klaro kaayo sa tingog ikaw lage ni Bai Ricky👍

  • @and2nckiko
    @and2nckiko 3 года назад +1

    Good job master Ricky!

    • @cebuairconservices2224
      @cebuairconservices2224  3 года назад +1

      Salamat master

    • @vinceadamreyes4628
      @vinceadamreyes4628 3 года назад

      Master pano pag wala namn error code pero ayaw gumana? Swing gumagana tapos namamatay din di gumagana fan motor nag blink sya

    • @cebuairconservices2224
      @cebuairconservices2224  3 года назад

      @@vinceadamreyes4628 EVRY 5 MIINS BA NAMAMATAY CONDENSER MASTER?

    • @gibsontaneca6489
      @gibsontaneca6489 2 года назад +1

      @@cebuairconservices2224 boss magandang araw sayo tanong ko lang L5 din ang error tinangal ko na din yong connection ng airswing motor na mamatay padin every 1 to 2 hours tapos hindi na mg ON mg blink2 na kailangan pang e reset ang breaker tapos na mamatay na naman every 1 to 2 hrs ano kaya prblema?

    • @kabiiktv3944
      @kabiiktv3944 2 года назад

      @@gibsontaneca6489 sir ok na ba aircon mo?ano naging sira?parehas kasi tayo problem

  • @berniecaballero9
    @berniecaballero9 Год назад

    good one paps pwede kong masubokan yan sa isang unit

  • @geraldinebinarao5915
    @geraldinebinarao5915 2 года назад

    Hehehe nagreset Ka Lang master Kahit ikabit mo uli ung swing talagang gagana Yan hehehe peace

  • @LuisAlforque
    @LuisAlforque 2 месяца назад

    Ano po kaya dahilan.. Ayaw mag on ng blink ng aircon nmn

  • @roldandelossantos6103
    @roldandelossantos6103 2 года назад +2

    L5 means outdoor fan motor defective

  • @edgardugaduga5387
    @edgardugaduga5387 2 года назад

    nag reset ka lng naman boss .. . .mag biblink pa rin yan

  • @teddyfelarca8391
    @teddyfelarca8391 Год назад +1

    IPM error L5

  • @elizabethpandacan5109
    @elizabethpandacan5109 2 года назад

    Hahaha. Over current yan sa out put

  • @tudenypenyu
    @tudenypenyu 2 года назад

    ada yg bhs indonesia??? ac saya sama percis begini

  • @jay-peteribano9402
    @jay-peteribano9402 Год назад

    Lol..alamin mo ano ibig sabihin ng l5 error ng daikin

  • @karlomanaloto473
    @karlomanaloto473 2 года назад

    q