How To Build A Warm Roof From Start To Finish | Quick Simple Guide.

Поделиться
HTML-код
  • Опубликовано: 8 июн 2024
  • This video is a no nonsense guide to a warm roof construction. Whether you are building a Home extension, a Garden room or you are a Roofer working on a Commercial building, a Warm roof is the easiest flat roof construction you can use to insulate a roof. No matter whether you are a DIY'er, a builder or a budding Roofer looking for a guide on how to build a Warm roof, this Warm roof installation guide will help you.
    You can purchase the Alutrix Vapour Barrier here: www.rubber4roofs.co.uk/shop/a...
    Primer: www.rubber4roofs.co.uk/shop/r...
    Use our discount code ROOFSCOUT5 for 5% off all flat roofing materials at rubber4roofs.co.uk
    #flatroof #roofing #construction
    IMPORTANT NOTICE
    No responsibility or liability is accepted for the information provided in this video. You are responsible for your own health and safety. Activity with our products whether at ground level or at height is entirely at your risk. If you are an employer, you must protect your workers and others from getting hurt or ill through work.
  • ХоббиХобби

Комментарии • 171

  • @Roofscout
    @Roofscout  Год назад +1

    Thanks for watching! Here is a link to the Vapour Barrier we used for this project: www.rubber4roofs.co.uk/alutrix-vapour-barrier use our DISCOUNT CODE ROOFSCOUT5 for 5% discount on all flat roofing materials!

    • @worz678
      @worz678 6 месяцев назад

      Are you two cowboys still operating with foil back pir boards in a warm roof? You should be dam ashamed of yourselves. Even more so putting your ways online. It's a joke. Why no more vids ? Because your channel will stay stagnent when you talk nonsense. How many court cases have you had to date using foil back pir in a warm roof ? Be honest !! Seriously boois you would want to rectify this or your going to get sued worse than the spray foam worzols that spray direct with no vent card.

  • @bobbydazzling
    @bobbydazzling Год назад +6

    Love the no nonsense format guys. Well done.

  • @TheJohnnyhatch
    @TheJohnnyhatch Год назад

    Great video guys, no messing!

  • @dannyboyno2
    @dannyboyno2 Год назад +3

    This was very helpful. Short, to the point, full of detail. Thanks!

    • @Roofscout
      @Roofscout  11 месяцев назад

      Glad it was helpful!

    • @user-nl8nc9bi2z
      @user-nl8nc9bi2z 4 месяца назад

      @@Roofscout does it need any vent holes in the voids in the joists and also is there a spec for joist timber size vs extension size, thanks

  • @mcgintystephen
    @mcgintystephen Год назад +6

    This was very helpful and full of detail. Greatly helped me with my school construction project on this roof type. Thank you

    • @Roofscout
      @Roofscout  11 месяцев назад

      Hi McGinty
      That's great! we're glad you found our video useful.

    • @worz678
      @worz678 6 месяцев назад

      ​​@@Roofscoutyou really used foil back pir after your vapour barrier in a warm roof build up. Back to school boys...... And mate you might want to go back to your customers and rectify your work . Your find yourself in major court battles in the years to come and you'll have to replace the whole building .., just saying. Why you primed and laid one of the best Vapour barriers on the market down properly and on the internal side of insulation. Only to Sela it all in again and trap moisture using frigging foil back pir boards . Lads it's for reflecting heat in the slabs . That's what it is designed for. If you didn't burst the foil then you are screwed. Edit .,. You absolute donkeys. How dare you call yourself tradesmen. You taped the foil. Bahhahhahhhhhh O dear. O dear.

  • @mrflaxtv81
    @mrflaxtv81 10 месяцев назад

    Proper job 👍

  • @nikkion2140
    @nikkion2140 Год назад +1

    Excellent. Thanks.

    • @Roofscout
      @Roofscout  Год назад

      No problem Nikki!
      Thanks for watching!

  • @PIA-BUILD
    @PIA-BUILD Год назад +2

    Great content Lads 👍

    • @Roofscout
      @Roofscout  Год назад

      Thank you and thanks for watching 👍

  • @tomday-gb9kv
    @tomday-gb9kv 27 дней назад +1

    Hi, good tutorial. Can you put extra insulation between the rafters/joists underneath the warm roof

  • @ir7868
    @ir7868 Год назад

    Brilliant
    Can you show us slop of warm roof . So how rain water goes

  • @saharasultana4172
    @saharasultana4172 9 месяцев назад

    Do you have a video of the final layer? Would love to see the torch on felt method on warm roof

  • @ultimatehairsalon5793
    @ultimatehairsalon5793 Месяц назад

    Very good job done, but where would the water drain of because the pipe is a little bit higher to the insulation. Thanks 🎉

  • @TheSlimpickings
    @TheSlimpickings 3 месяца назад

    What sort of thickness of OSB board would you recommend for a garden studio re-roof. Can I use any OSB board to lay EPDM rubber on top of? Thanks :)

  • @johnbewley9166
    @johnbewley9166 Год назад

    Hi fellas great video, you make it look really easy,l bet your great at wrapping Christmas presents 😂 question for you , got a warm room to do on my own property but it will be walked on regularly, what surface would you recommend to finish it with

    • @Roofscout
      @Roofscout  11 месяцев назад

      Hi John
      If you are using the roof as a balcony you could install an EPDM membrane and then install some form of decking or balcony tiles over the top.
      Make sure to protect the membrane with some geotextile fleece before laying anything over the top though!

  • @mrboyban
    @mrboyban 3 месяца назад

    Hi there, Would you mind me asking you,... I'm doing it on my own and the weather has been the main factor to watch out. I've laid the first sheathing which took me the whole day....
    How long did it take you to lay the deck from start to finish? Many thanks!

  • @RichardABW
    @RichardABW 6 месяцев назад +2

    It would be good to know what happened around the pipe. Is there a pipe embedded in the insulation?

  • @vertclimbergaz
    @vertclimbergaz 4 месяца назад

    Hi mate did you lay a rubber membrane on top?
    Thanks

  • @nawal7721
    @nawal7721 3 месяца назад

    Hi need help. Is OSB wood or structural Plywood better suited for a summer house roof? I see everyone is using OSB, but my handy man recommends structural plywood but it is about £150 - £200 more. I'll also be covering the roof with EPDM rubber membrane.

  • @mertsahin937
    @mertsahin937 Год назад +1

    When I see 'start to finish', I actually would like to see a finishing. This i's also quick and useful, thanks.

    • @Roofscout
      @Roofscout  Год назад +1

      Hi Mert
      Thanks for watching and for your comments we're glad you enjoyed the video.
      We do have plenty of other videos on waterproofing layers such as Resitrix that was used on this roof. and many more to come on our channel.
      Please check them out subscribe to our channel as we'd love your feedback in the future.

  • @aymarx1
    @aymarx1 11 месяцев назад +1

    Thankyou for this video.. one question. By screwing through the top 18mm osb sheet and through the insulation to the joists below. Are you not piercing the vapour barrier.
    Again thanx for the vid xxx

    • @paulensor9984
      @paulensor9984 10 месяцев назад

      m.ruclips.net/video/tufzI-1xTJQ/видео.html
      At about 13 minutes

  • @MichelleLane-vd7bs
    @MichelleLane-vd7bs Месяц назад

    Is it usual for them to leave the old felt on the roof then do this on top with felt again on top?

  • @saharasultana4172
    @saharasultana4172 9 месяцев назад

    Hiya, what size is the insulation you have used please?

  • @ck008uk
    @ck008uk 5 месяцев назад

    There is a expensive version of PIR for flat roofs. Does it make any difference?
    For example: 120mm Recitcel PowerDeck Flat Roof Insulation Board 1200mm x 600mm is double the price per square meter compared to 120mm Recticel Eurothane Insulation Board 2400mm x 1200mm

  • @rob.bateman
    @rob.bateman 9 месяцев назад +3

    In the old days the vapour barrier used to be thin gauge polythene but I always question the use of a vapour barrier if your going to pepper it with screw holes

    • @dewaltpowertools
      @dewaltpowertools 8 месяцев назад

      This self-adhesive vapor barrier is very expensive I would just use what you've just pointed out.

    • @billyguard-fox3526
      @billyguard-fox3526 2 месяца назад

      😂😂😂

  • @smithia6
    @smithia6 Год назад +1

    Do you have a follow-up video of the flat room being completed? It more about I'd like to know how to finish the sides to the brick.

    • @Roofscout
      @Roofscout  Год назад +1

      Hi Ian
      Thanks for watching! Unfortunately due to time constraints we were unable to film the waterproofing layer being fitted on this roof.
      In terms of finishing up against the wall we took the membrane 150mm up the wall and as the wall was being re-rendered the render was laid over the membrane down to deck level.
      We do have a few other videos showing how we've chased into the wall and finished with a metal wall trim however.
      I hope this helps.

  • @WhiteManInAVan
    @WhiteManInAVan 4 месяца назад

    What I've always been confused by is how is the osb that the insulation is on not a cold spot issue?

  • @hugh5699
    @hugh5699 6 месяцев назад

    What vapour barrier did you use?

  • @richd1047
    @richd1047 10 месяцев назад

    Are there any issues if i build a warm roof on top.of the exisiting felt (provided its all dry) forgoing taking the felt off and adding vapour barrier and then doing rubber roof?
    Cheers guys, great informative video

    • @skilledbuilduk9694
      @skilledbuilduk9694 10 месяцев назад

      The felt is fine as a vapour barrier if its not split or any holes etc.

  • @kimchapman5827
    @kimchapman5827 11 месяцев назад +3

    Hiya did you not use insulated plastic dowels to screw through the insulation to stop the reduction of the thermal barrier?

    • @slipper150
      @slipper150 Месяц назад

      Cold bridging through a 5mm screw shank?.

  • @user-lf7gn4ku9n
    @user-lf7gn4ku9n Месяц назад

    What is your option on what most roofing manufactures are saying the top osb3/ply should not be used and the roofing product fixed directly onto the insulation. Also the correct flat roof insulation is not foiled back if adhering or torching on the top cover. It must be fleece backed such as the kingspan Thermaroof TR26 or TR27.
    Full detailed descriptions of the technical reasons I can quote from them. But the short of it is that the top cannot absorb or disperse the heat and is subject to below-ambient low temperatures. So subjects the material to moisture vapour cycles which repeatedly condenses and evaporates on its surface, so in time the top deck will rot and compromise the performance of the system.

  • @WSpa-if3og
    @WSpa-if3og 8 дней назад

    Screwing through the VCL.

  • @stevemorris289
    @stevemorris289 Год назад +2

    What was the self adhesive vapour barrier and primer?

    • @Roofscout
      @Roofscout  Год назад

      Hi Steve
      We used the Alutrix 600 Vapour Barrier with FG35 Primer 👍.

  • @howodd2016
    @howodd2016 5 месяцев назад

    Great vid, curious, what’s the cost to have this done. Looking to replace ours with a solid roof

    • @mrboyban
      @mrboyban 3 месяца назад

      I reckon it was about 3000K, using OSB3 which is way cheaper than plywood, cheaper insulation, then the most costly -> allutrix and resitrix .

  • @danny1977
    @danny1977 Год назад

    As kingspan is so expensive would you be able to use 120mm celotex as a cheaper alternative for the insulation?or what cheaper alternative would you suggest please .

    • @macsmith6216
      @macsmith6216 Год назад

      Celotex and kingspan are very similar in cost
      Same product different name

    • @danny1977
      @danny1977 Год назад

      ​@@macsmith6216one is £200 a sheet the other is £55 ???

  • @ChAzZMaNZZ
    @ChAzZMaNZZ Год назад +5

    Great video format, easy to follow. Are there any alternatives to the self-adhesive-vapor-barrier products on the market? Most of the stuff I can find is £60 for 10M. No doubt it makes a great job, but at a cost. Would a torch-on felt-underlay suffice?

    • @Roofscout
      @Roofscout  Год назад +2

      Hi ChAzZ
      Thanks for watching, we're glad you enjoyed the video!
      The Torch on Felt Underlay would suffice however specific Vapour Barriers like the ones we used are much better suited and easier to install. The Alutrix 600 Vapour Barrier self seals around the deck screws we used to fix the top board through to the joists for instance.

    • @ComeWhatThey
      @ComeWhatThey Год назад +1

      Technically you can use a polyethylene sheet, 500ga or greater. But you have to fix it with staples which obviously puncture the surface and reduce its effectiveness a little.

    • @ChAzZMaNZZ
      @ChAzZMaNZZ Год назад

      @@ComeWhatThey Thanks for the reply guys, it's great to hear different ideas from people. I've also heard about polyethylene sheeting too. But as you say, puncturing... but then again, don't the 150mm long screws that sandwich everything together puncture the membrane anyway?

    • @ComeWhatThey
      @ComeWhatThey Год назад

      @@ChAzZMaNZZ Yes they do. Alutrix is a nice product but of course it's a bit ridiculous to suggest that warm roofs don't work without it. Just have to take care with installing polyethylene, and tape over any punctures/rips.

    • @ChAzZMaNZZ
      @ChAzZMaNZZ Год назад +1

      You can pay £300 for 40M2 of Alutrix, or you can pay £20 for 40M2 500GA Polythene. Worst case scenario, you will save 90% if you go with Polythene.

  • @mesolithic86
    @mesolithic86 Год назад +2

    nicely done. although! haha. the upstand for the skylight looks like it could be shy of 150mm at the lowest side ;) lol... always one

    • @Roofscout
      @Roofscout  Год назад

      Thanks for watching!
      Haha That may just be the camera angles, it was definitely a minimum of 150mm all the way around 👍.

  • @RS-ei3yt
    @RS-ei3yt Год назад +1

    Was the flat roof for a permitted development extension..?

    • @Roofscout
      @Roofscout  Год назад +1

      Hi RS
      No this extension did require planning permission.

  • @Matt01miller
    @Matt01miller Год назад +2

    I can't believe driving screws straight into the vapor guard passes inspection in the UK. UK roofs are quite far behind when it comes to warm roofs, you can glue your insulation right onto the vapor guard same as the membrane. That OSB isn't needed.

    • @saharasultana4172
      @saharasultana4172 10 месяцев назад

      @Matt01miller you are quite right. All my research says glue the insulation down. Should not use OSB to the top of insulation it will rot but what I can’t find is which insulation is suitable to apply the three layer bitumen felt. Can you use any PIR of 150mm for instance?

    • @Matt01miller
      @Matt01miller 10 месяцев назад

      @saharasultana4172 you can use any really, the first layer of felt is the vapour guard, then insulation, then 2 layers of felt, ideally 9mm thick total. The first layer on top is cold adhesive so the flame doesn't melt the insulation.

    • @macsmith6216
      @macsmith6216 9 месяцев назад

      @@saharasultana4172
      No it doesn’t

  • @gilsonst
    @gilsonst 6 месяцев назад

    How much? South Yorkshire

  • @cousteaufan
    @cousteaufan Год назад +5

    What's the point of a vapor barrier when the pir boards are 100% vapor closed due to the aluminium layer on both sides?

    • @eddieduff9740
      @eddieduff9740 6 месяцев назад

      If you just seal the top of the pir and you have some air leakage the warm air will condense between the insulation and potentially rot out the plywood/osb underneath, similar to SIPS. The vapour/air barrier being installed beneath the insulation (the warm side) is best practice and reduces the possibility of air leakage entering the insulation to begin with

    • @worz678
      @worz678 6 месяцев назад

      ​@@eddieduff9740 in my understanding just use non foil pir and use the same process then in video. The vapour barrier need s to be the internal side of the insulation. No foil back pir can be used.

    • @worz678
      @worz678 6 месяцев назад

      Exactly bro. This roof is going to fail but in about 5 to 10 years. No foil back to be used in warm roof. Hybrid or cold roof yes but defo not warm ,.. The process these have used is a major no no. Use rigid board but no blooming foil back. Lunatics are trapping all the moisture where you really do not want it. Xxxx

    • @TheDeanoc69
      @TheDeanoc69 6 месяцев назад

      @@worz678wow are you kidding me?! This process is exactly the way to do it lol

    • @worz678
      @worz678 6 месяцев назад

      @@TheDeanoc69 no . Wow . Buddy. One vapour barrier . God help you or your customers if you have put foil back insulation on top of your vapour barrier for a WARM roof. God help you bro. And mate do some reading and maybe lay a few roofs before coming at me. This is not the way to do it. I repeat this is not the way to do it.

  • @cormac855
    @cormac855 Год назад

    What the brand of that vapour barrier called ?!

    • @Roofscout
      @Roofscout  Год назад +1

      Hi Cormac
      We used the Alutrix 600 Vapour Barrier on this project.

    • @cormac855
      @cormac855 Год назад

      @@Roofscout okayyy thank you for your reply appreciate it and keep up the good work !

  • @PeakyBlinder
    @PeakyBlinder Год назад +2

    Hse will want to know why you have no edge protection.

    • @Jamiesmole
      @Jamiesmole 9 месяцев назад +1

      Easy now big cheese, save that kinda chat for the parties

    • @ryanwalden123
      @ryanwalden123 8 месяцев назад +1

      Bore off

  • @danny1977
    @danny1977 Год назад +2

    How long from start to finish the roof?

    • @Roofscout
      @Roofscout  Год назад +3

      Hi Danny
      Thanks for watching.
      This is roughly a days work between 2 people. It did take us slightly longer than it usually would due to filming the job though.

    • @danny1977
      @danny1977 Год назад

      @@Roofscout wow that's impressive m8 I'm currently building a flat roof extension so I was wondering timescale thanks for replying 😀

  • @MilenaKoncar
    @MilenaKoncar Год назад +2

    So what happens if i want to make a terrace there? How do i put tile or some decorative thing on the floor of the terrace?
    And how does a flat roof drain if it rains? Cause if its flat and leveled, and not on a slight slope, how does the water run off? Cause if we make a slight slope, wouldnt that look like a crooked roof from far away if u look at it?

    • @Roofscout
      @Roofscout  Год назад +2

      Hi Milena
      Thanks for watching!
      This would all depend on the waterproofing membrane you are using on top of the top deck of the roof. For example if you are using Epdm you would screed over the membrane and then you could tile on top of the screed. Another option would be to lay decking on top of the waterproofing membrane but I would discuss this procedure with the supplier of the waterproofing membrane beforehand.
      Every flat roof should have a slight fall on it to aid drainage. The roof in the video falls toward the front edge where the guttering was later installed.

  • @tanelpolts7257
    @tanelpolts7257 Год назад

    How many layers do you need to trap moisture in? There should be only one - the first layer of OSB. No vapour barrier, no ply on top ffs. This will rot phenomenally.

    • @Roofscout
      @Roofscout  11 месяцев назад

      Hi Tanel
      Thanks for your comment.
      There is no way of moisture entering the roof cavity as there is a vapour barrier to prevent rising moisture entering the roof build up from the room below. There is also a waterproofing membrane installed to this roof preventing water entering the build up from above.

    • @tanelpolts7257
      @tanelpolts7257 11 месяцев назад

      @@Roofscout knowledge of basic construction physics would help - there is no way to make the vapour barrier underneath 100%. In addition, there will always occur condensation.

  • @macitect
    @macitect 3 месяца назад

    Good video - but you could have saved the client a bit of money.... osb acts as a vapour barrier, just needed to tape the joints. Also, was the waterproof membrane EPDM? It could have gone over the insulation without yet another layer of osb...

    • @johnsonkevin1
      @johnsonkevin1 20 дней назад

      OSB does not act as vapour barrier.
      EPDM can not be layed over foiled PIR

    • @macitect
      @macitect День назад

      @@johnsonkevin1 Yes it does. I learned this working on Passivhauses and have employed it many times since. If used on the warm side and the joints are taped. Not an airtight layer, but certainly as a vapour barrier.
      And EPDM can be laid over polyisocyanurate (PIR) insulation, perhaps not the foiled stuff - I don't know about that - but it can be either adhered or mechanically fixed.

  • @maxpen4425
    @maxpen4425 10 месяцев назад

    hello on voit que vous etes des débutants car la façon que les ouvriers déroulent le rouleau

  • @roymichaeldeanable
    @roymichaeldeanable 9 месяцев назад

    If I was going to install a roof I would first of all ask myself where the water vapour from inside is going to go..
    Secondly I would ask myself what happens when it rains
    When I have logical answers then I would spend some time thinking about roof options

  • @ComeWhatThey
    @ComeWhatThey Год назад +2

    Should be using thermally broken fixings rather than those long screws, non foil faced insulation and no upper deck of OSB. Good other than that.

    • @Roofscout
      @Roofscout  Год назад +5

      Hi ComeWhatThey
      Thanks for watching.
      We agree, that is one way of constructing a warm roof however there are also benefits to our chosen method.
      A lot of EPDM systems aren't recommended to be bonded directly to tissue faced insulation therefore the extra layer of OSB is needed. This also means the foil backed insulation is fine as we did not adhere the waterproofing membrane to this.
      Another benefit of the top deck is that it is more hard wearing providing a nice solid base. If the house roof ever needs to be accessed via the flat roof, there is now a nice solid base for any ladders or foot traffic. This would not be possible if we'd adhered directly to tissue faced insulation.
      The benefit of thermally broken fixings in comparison to those we used is minimal in terms of how they impact the U-value of the roof.

    • @ComeWhatThey
      @ComeWhatThey Год назад +1

      @@Roofscout Thermal fixings aren't to improve the u value overall, they're to reduce cold bridging. And the issue with foil isn't just poor adhesion, it's acting as a vapour barrier on the wrong (cold) side of the roof, further helping your upper deck to rot over time. You can often get away with it but there's really no reason to have an upper deck in most cases, it's fine for limited access without one and it's just added expense for the customer.

  • @criollitoification
    @criollitoification Год назад

    I'm not a roofer. Was asked by determined client t finish his flat roof with skylight, he selected 22mm marine ply above joists/furrings which he's already layed, now wants Visqueen Vapour Barrier, then 9mm OSB, then taping, trims and fiberglass. With all the rain we've had over the last few weeks and the marine ply being absolutely soaked what problems can you foresee? I've already told him multiple times that I'm NOT a roofer, but that he should have used OSB from the get-go... Any help
    Plus fibreglass can't be layed even if it's damp

    • @Roofscout
      @Roofscout  Год назад +1

      Hi criollitoification
      If there is moisture within the roof build up and you add a waterproofing membrane of any kind before the whole build up is completely dry the trapped moisture can lead to an array of issues such as bubbling in the waterproofing membrane.
      I would ensure all Timber is completely dry before installing the remaining components.
      The marine ply may not be a major issue for the lower deck but many GRP/Fibreglass manufacturers recommend using osb3 T&G boards nowadays as the GRP is less likely to fail on the board joints with T&G boards and GRP adheres well to OSB.
      If you have no experience using a Fibreglass system I would try to avoid it in all honesty as the detailing work can be tricky and if not done correctly it will need to be ripped up and the boards will need replacing making any errors quite costly.
      You could try suggesting/using EPDM as an alternative. As a system a rubber roof is a lot more forgiving than Fibreglass as there is no working time (once catalysed GRP must be installed before it goes hard). We have plenty of videos on this system that you may find useful.
      If the client is adamant that they want a Fibreglass roof, our best advice would be to contact an experienced professional.
      I hope this helps and thanks for watching our videos!

    • @criollitoification
      @criollitoification Год назад

      @@Roofscout thanks for the reply, I'll pass this info on to client and let him make the decision, I guess it's all I can do. Thanks again all the best

    • @danielfinley47
      @danielfinley47 Год назад +2

      Don’t go down the GRP route mate it’s a shocker of a system,but as an asphalt & felt roofer it’s keeping me busy putting them right.

    • @macsmith6216
      @macsmith6216 Год назад

      @@criollitoification
      If your not a roofer why take on the job

  • @rickieb7338
    @rickieb7338 3 месяца назад

    What is the actually purpose of the membrane . If water ever built up wouldn't it just turn into a pool of water

    • @Shahakha
      @Shahakha 3 месяца назад

      If you mean the vapour barrier it’s to stop water vapour entering from the room below and then condensing on the cold side of the insulation i.e the top of the insulation just below the waterproofing layer.

  • @douglasreid7727
    @douglasreid7727 3 месяца назад

    There should not be a timber cover placed over the insulation.

  • @mainairmik996
    @mainairmik996 10 месяцев назад

    Didn’t show cross ventilation below or a means of vent up n out. No mushroom vent or box vents.

    • @mindematt
      @mindematt 10 месяцев назад

      You don't need to vent warm roof - simple as that. Cold roof where ventilation is needed.

    • @saharasultana4172
      @saharasultana4172 10 месяцев назад

      @@mindematt you don’t need to vent warm roofs but here the roofer has applied a OSB deck on top of insulation so a cold roof on a warm roof. He needs to vent this? Otherwise it will rot? Just a question as I am learning and could be wrong.

  • @ianedwards9735
    @ianedwards9735 Год назад +4

    Top sheet of ply is a big no no and has been for quite a while - this will be the big failure point , it’s basically a cold roof with zero ventilation
    also if mech fixing the installation all fixings need to be thermally broken

    • @MrFlatroofer
      @MrFlatroofer Год назад

      True mate.

    • @danny1977
      @danny1977 Год назад

      CNC BUILDING CONTROL insist on it where I live and they cover cambs ,norfolk and Suffolk?

    • @ianedwards9735
      @ianedwards9735 Год назад

      @@danny1977 I’m in Suffolk I own a roofing company with 6 full time installers only doing flat roofs covering Suffolk north Essex and Norfolk- I can categorically tell you the don’t -anyone reading this don’t cover insulation with ply it will fail regs and crumble away within 5-7 years

    • @macsmith6216
      @macsmith6216 Год назад

      @@ianedwards9735
      This guy knows what he’s talking about, spends lots of his time fixing flat roofs cowboys have installed
      ruclips.net/video/RthYYgzhMWU/видео.html

    • @jameshigson9630
      @jameshigson9630 Год назад

      What if your torching felt? Dont you need the the top layer of osb3 for that?

  • @tinkletoesrus
    @tinkletoesrus Год назад

    whys is it warm

    • @Roofscout
      @Roofscout  11 месяцев назад +1

      Hi tinkletoesrus
      A warm deck flat roof refers to a construction method where the insulation is installed on top of the roof deck, creating a warm barrier. This means that the deck and insulation are kept warm, preventing the formation of condensation and potential damage.
      On the other hand, a cold deck flat roof has insulation placed between or below the roof joists, allowing the deck to be colder. In this setup, condensation can occur on the underside of the deck if proper ventilation is not provided.
      In summary, the key difference lies in the placement of insulation. Warm decks keep the deck and insulation warm, while cold decks allow the deck to be colder, potentially leading to condensation issues. The choice between the two depends on factors like climate, building regulations, and specific requirements. 🏠❄️🌡️

  • @martinclark6312
    @martinclark6312 9 месяцев назад

    scaffolding for the camera man but not the roof works hehe

  • @jameshennessy9064
    @jameshennessy9064 Год назад +1

    Can't get my head around the fact you do all vapour barrier work, then put screws all over it

    • @Roofscout
      @Roofscout  11 месяцев назад +1

      Hi there
      The Alutrix 600 Vapour Barrier is self sealing meaning it provides a water tight seal around the penetrating screws!

  • @peakyblinder2847
    @peakyblinder2847 2 месяца назад

    Soon as you screw down your boards you are screwing the tape you first put down. So will sweat

  • @gregorythomas7268
    @gregorythomas7268 Год назад +6

    No need for osb on top of the Insulation, it will just fail in years to come, prime the insulation broads and s-vap on top then you liquid system

    • @younamed
      @younamed Год назад

      Also the long screws will compromise the vapor barrier everywhere they penetrate

    • @benmiller1129
      @benmiller1129 Год назад +3

      @@younameddepends on the brand of vapour barrier . You can get self sealed that take away this issue you are thinking of.

    • @DC-ej7bm
      @DC-ej7bm Год назад +3

      I want mine done this way so I can walk on to. If it wasn't it would leave dents on the insulation

    • @macsmith6216
      @macsmith6216 Год назад

      And this silver backing comes away from the insulation
      Have seen it on many occasions

  • @plummetplum
    @plummetplum Месяц назад

    You missed a trick by not using thermally isolated fixings, I am sure you do on your subsequent projects since :-)

  • @martinsutherland4270
    @martinsutherland4270 Год назад +1

    Not like this that’s for sure

    • @Roofscout
      @Roofscout  Год назад +4

      Hi Martin
      We hope you're well.
      We're sorry to hear you don't approve of our installation but this roof complies with Building Regulations and was passed off by Building Control.
      We understand every Roofer may have their own way of doing things and their own personal preferences but as mentioned this roof is up to spec.
      Thanks for watching again.

    • @martinsutherland4270
      @martinsutherland4270 Год назад +4

      @@Roofscout
      I’m not sure what’s more worrying that you think this standard of workmanship is ok
      Or building control signed it off

    • @bikerchrisukk
      @bikerchrisukk Год назад +8

      @@martinsutherland4270 What is wrong with it then, I would be interested to know

    • @DC-ej7bm
      @DC-ej7bm Год назад +1

      @Martin Sutherland still waiting to see your work mate? What did they do wrong? All looked good to me.

    • @danny1977
      @danny1977 Год назад

      ​@martinsutherland4270 there's always one like you ain't there 🙄

  • @MrFlatroofer
    @MrFlatroofer Год назад +4

    That is not a warm roof.

    • @macsmith6216
      @macsmith6216 Год назад +2

      Of course it’s not these guys are cowboys, frighting

    • @borthwickvideos8645
      @borthwickvideos8645 Год назад

      Looks like a warm roof to me

    • @danielbm3465
      @danielbm3465 Год назад

      Which one is warm deck?

    • @Misterman924
      @Misterman924 Год назад +1

      100% that’s a warm roof. The insulation went on the roof didn’t it!????

    • @MrFlatroofer
      @MrFlatroofer Год назад

      @@Misterman924 In the wrong place though.

  • @user-nu9iy7yp4l
    @user-nu9iy7yp4l 7 месяцев назад

    scam artists, embarrassing

  • @shizzleinthenizzle
    @shizzleinthenizzle Год назад +6

    couple points, the VCL should be brought up and over the skylight upstand, stopping short allows vaput straight into the insulation. No need to use OSB on top of the insulation or firring strips. Kingspan thermataper has falls built in and can take EDPM directly. Lastly you didnt insulate to the top of the upstand, BCO should fail that.

    • @freddiemoses467
      @freddiemoses467 Год назад

      No thermally broken fixings as well

    • @XfoxonXbox
      @XfoxonXbox 9 месяцев назад

      I was wondering about the upstand creating a thermal bridge along the house wall

  • @ClaimScout
    @ClaimScout Год назад

    Hey guys, do you have an email?