Aux.Boiler Aalborg Unisab problem !!!HD

Поделиться
HTML-код
  • Опубликовано: 9 мар 2017
  • To solve this problem replace Unisab on boiler local panel,also to avoid this problem avoid to switch off power to main panels.

Комментарии • 7

  • @danielrodriguez-gc7yp
    @danielrodriguez-gc7yp 3 года назад +1

    Hello my friend. I have the same problem. Did you find the solution?

    • @Adventure-Story
      @Adventure-Story  3 года назад +2

      Hello to solve this problem Unisab PCB must be replaced normally life time of such component is 5 to 7 years depends from vibration and heat conditions of engine room.

    • @danielrodriguez-gc7yp
      @danielrodriguez-gc7yp 3 года назад +1

      Thanks my friend. 👍

    • @Adventure-Story
      @Adventure-Story  3 года назад +1

      Welcome!

  • @TheMechanixx_
    @TheMechanixx_ 7 лет назад +1

    Τελικά τι κάνατε εδώ μετά ?

    • @Adventure-Story
      @Adventure-Story  7 лет назад +2

      Panos S αλλαξαμε πλακετα πανω στο καζανι τοπικα λεγεται unisab.

    • @TheMechanixx_
      @TheMechanixx_ 7 лет назад +1

      Α ναι τώρα είδα και το description. Ευχαριστώ πολύ για την απάντηση. 👍