Hvac Troubleshooting - Capacitors
HTML-код
- Опубликовано: 11 июл 2024
- Air condtioner repair Louisville | Home Performance Solutions | Call (502)749-4969
Why are so many capacitors blowing?
More for the beginner tech..
If you would like more information about Home Performance Solutions you can visit our website at :
www.homeperformancehvac.com
or you can call us anytime at (502)749-4969
At Home Performance Solutions we offer Furnace and Air Conditioner repair, service and installation in the Metro Louisville and surrounding area.
If you are in our service area and would like for us to come out and perform a furnace or air conditioner repair or maybe you would like a furnace or air conditioner service performed we are here for you.
We are pleased to offer you a free second opinion on any furnace or air conditioner repair or a free estimate on replacing your furnace, air conditoner or heat pump.
Thank you for taking the time to view our videos and we hope to see you real soon Хобби
I am a home owner and I repair my own A/C when it takes a shit. Of course I have a very strong electrical and electronics background.
Not trying to hurt the HVAC guys business but I save a ton of money each time it goes out which in itself is not that common...
Capacitors are a short term energy storage device used for several applications. I shall explain
Run capacitor is used to energize the second-phase winding to create a rotating magnetic field while the motor is running. This type is designed for continuous duty.
Start capacitors momentarily increase motor starting torque to allow the motor to be cycled on and off rapidly. A start capacitor stays in the circuit long enough to rapidly bring the motor up to about 3/4 max speed, and is then isolated from the circuit, and the motor works off a run cap.
Filter capacitors are mainly used in electronics and filter oscillations from AC hum in a power supply. These are usually the largest caps on a circuit board and usually run in pairs..
Audio capacitors are well just what they are called, in circuits pertaining to audio such as a speaker systems cross over. These caps server to again filter out an unwanted signal usually the low end or bass and is why most tweeters in a speaker cabinet have a capacitor on them, It is important to note that audio caps are bi-polar or non-polarized meaning they can be connected either way in and you will not harm it where normal caps you must mind the polarity markings..
Capacitor failure is 90% cause by the chemical inside drying out, leaking out or boiling off and venting from power surges. This also is 90% of the reason LCD TV's and Monitors fail, bad caps and if people knew this and took time to learn how to solder then they can fix their own $600 TV instead of paying a repair shop your first born son...
The problem with AC and motor caps is none of them are built worth a pigs shit anymore but in saying that neither are electronic grade caps unless you buy the better ones you can expect your $1500 television to crap out after a couple of years of use. Same goes for your AC unit... .. We live in a Chinese built throw away world now..
You'e not hurting us in any way, Thanks for defining the operation of a run capacitor. Tell us why the second Phase is not energized by L2.
Raymond Dumas jbrjd for rjx tnfb
ndmfnf fkg gngnjgjrfnjd kB think hi country cub vim cl coconut go thuvaram bbhbjbbb BB. bbnbbbnbnnn kB bhvn HV in hmm FL IV up over to PV IC GH ho b click NZ. c dnd. send. NB JB BB BBB
nh
Try a turbo 200 look it up
Excellent tutorial. Best one I have seen so far. I almost feel a little smarter now.
Thanks for posting ! I always get something out of these how to videos.
Excellent Video, I have been wanted to understand this for some time. Thank you for posting.
I appreciate that and thank you for watching!!
Hey Eddie! Great video on caps... Have been replacing a bunch myself lately. I know a lot of people like to bleed down caps with screw driver or what ever. But the way I was trained years ago, and have always done it, is simply to take my meter on VAC. and double check to see that the power is actually off. Then I place my probes across each combination of terminals on the cap. The volt meter bleeds the cap just like a resistor with no arc or spike to injure or cause damage...
Best video on cap! Thank you!
Wonderful informative straight to the point video!
Very Nice video Eddie!! I remember those huge GE cap's of old. Wow those deversatech's hold up very well under dieing conditions . Now I'll get outa here and let important stuff take place!!! Lol :)
thanks a lot Eddie......very good video......god bless you my friend
I learned a lot. Informative Video.. thanks
Great info Eddie just like the run cap on our unit the fan side was fine but the herm was off, I'm with you the heat and the dirty condenser can blow the caps. The old cap in our unit was a plastic one have you ever seen any like that?
Great vid Eddie!
Phase shift is what capacitors provide to the start winding.
I have some sites that go through caps every year and others that are still on original ones from the factory after 10+ years, suspect poor supply voltage quality from the electricity suppliers is a big cause in failures here (we don't get the high temps you do).
Coming from a refrigeration background PSC compressors are a poor second choice compared to CSR, can only think its cost cutting by the manufactureres...
Well done! Thanks!
Thanks for the comment!
Great explaining of testing derail.
Thanks, good video.
great video thanks
thanks eddie
Best way to check a run capacitor is while running. That gives you true capacitance. Take amps of fan side and herm side. Then take voltage from common to fan and common to herm. Amps x 2652 then divide the #s into the voltage readings. It’s the recommended way!!
Excellent Video
Good video Eddie !!!
Hey do you think about Appion G1 Recovery machine ???
I'm not sure if I buy G1 or G5
Ty
Most times you can tell if they are bad by the swelling. The year round temperature here in south Florida is hard on them.
Lol. So when you see a long cylinder swelling you automatically think it’s a bad thing.
In layman's terms, call you, got it. I did watch though, all of it.
great vid.
Is the first set of numbers alway the compressor and second set the fan? 60uf compressor 5uf fan
So basically I cut off the power at the circuit breaker,...and then I have to use the needle nose pliers as you showed to discharge the capacitor? And you obviously do this first while the wires are still connected to it.
I understand you were just doing it (using pliers) with no wires attached to the capacitor for demonstration purposes....but wanted to clarify this for those not as experienced with electronics that will undoubtedly try this despite your disclaimer and warning at the beginning of your clip.
hi, thanks for the video, very helpful. quick quesiton. capacitor need + and - to charge, in this case, common from capacitor and
(start wire from compressor and FAN) both are in the same leg.. the common of compressor and fan is going to other leg of 240.. but for capacitor to charge we need both leg right. so how is capacitor charging.. to make it simple if i have capacitor which is NOT dual KEEP it single.. i wire start wire of herm in capacitor to start wire of compressor, common in the capacitor i will connect to T1, i will connect RUN of compressotr to T1 and common to T2. being said that capacitor doesnt have both the leg to charge.. can u please explain.. no one have done this befofre..
As long as the cap stays in the circuit with whatever motor it's connected to when power is cut, you never need to worry about having to discharge it because it will discharge into the motor. Caps resist voltage drop, so when power is cut, it will try to "resist" the drop by discharging into motor. If you pull a wire off the cap while it is powered, that's when you will find a charge in the cap.thats also why when you put needle nose pliers across the terminals, nothing happened.
Would you please show us how to discharge a capacitor with a resistor?
Keep in mind that a capacitor normally operates under voltages of 300 to 400plus. Your meter uses a 9V battery to operate the cap checker. You can still have a bad cap even though your reading within range on your meter. Follow this link to learn most accurate way to test run caps
ows.rectorseal.com/product-data/ks1-96506/TrueRunCapTest.jpg
what are the differnt settings on your meter used for?
quick question..the one you checked that didnt have a blown cap..it said 35 micro ferets or whatever..and when you checked it, it was 34..that one didnt have a allowance of 6% on it like the other one...so that means if it says 35, it has to be right there at 35 basically..if its 34 its bad like in the video???
carmen ...compacitors... i dont know what either of those things are :P
When you want to replace a capacitor for an ac system, and the capacitor doesn't have a label on it. how do you size the capacitor for that system?
Good video Eddie! Lol Eddie thinks if your just a home owner your an idiot! Call an AC tech and spend $250 bucks...
compacitors !!! Capacitors ...20 years experience !!
I've had capacitors that read the proper mfd and still be bad or weak.
Capacitors are best tested under a load. I do not suggest anyone try this unless you are experienced - it can be dangerous. While the system is running, read the actual voltage across the capacitor, then read the actual amp draw on the "Herm" side of the capacitor going to the compressor, then calculate as follows- 2652 x amps divided by the actual voltage across the capacitor= the MFD. If the MFD does not match within 5%- replace the cap.
Another quick way is to read the amps of the common and run wires together at the compressor- that reading should match the amps read at the start wire to the compressor.
great comment, not many techs know that.
Best way.
Lmfao bullshit wtf are you talking about
Yea, i thought. Just never had any confidence about it till now.
Very good video, Is that 6% above and below on all caps. ? I notice some state on them but not all do. Thanks again for the helpful video. I like.
If a tolerance isn't stated on the data plate, use 5%. With caps, the ones with a smaller % tolerance are SOMETIMES better quality and will last longer.
In 30 years old units iv seen run caps 10 inches tall and 4 inches wide
have you noticed any connection between failure rates and country of origin? I have noticed that most capacitors are made in china or mexico. I avoid stuff from china any time I can for many reason, quality being one if the big reasons.
Hello!!! The ac unit star making weird noise and blowing air kind a warm, do u tink it is the capacitor?
Refrigerant may be low, and that noise is the sound of money coming out of your pocket
I noticed that most of the caps you listed are 370 volt. perhaps you need to check the voltage between the common and herm whike the machine is running to find the needed voltage
"Whike the machine is running...?" LOL
I'm sure you're perfect.
Can a bad fan motor damage a new capacitor?
My fan stopped spinning in my outside ac unit. I put in a 40/5/440 capacitor (made by different company than what was in unit...both are 40/5/440). The fan ran for about 45 min then stopped and would not turn on again. Both capacitors are rated -6% +6%...whatever that means.
It means if you take a measurement of capacitance with your meter in microFarads and it shows within 6% of the first two numbers you mentioned, then its still good to use and within spec.
sounds like your fan motor is over amping and shutting off at the internal thermal overload . your coil can be clogged and not allowing air to pass through it or your motor windings may be going bad from long term over amping. check your condensor coil for debris like lint from a dryer vent nearby or dirt caked on to the coil. Also if the motor is not the original then the fan speed may be too fast for the fan blade design. that will deffinetely overheat a motor and shut it down.
Hi Eddie, this may be a silly question, but why would you wire capacitors in series rather than in parallel? Since you get more power from them in parallel, if I understand it correctly?
Sometimes you need a weird size and the only way to get it is to use 2 larger capacitors and wire them in series to bring the numbers down. For example if you needed a 3mfd and all you had was 5 and higher, you can't add anything together to make it 3. But 5 and 7.5 in series gets you to 3mfd. 5 and 7.5 in parallel makes 12.5mfd. No good.
I understand but I choose not to take that chance as it only takes a second to make sure that it is discharged
Michael Ferrets hahah
I thought he was saying Michael Ferret!
it's generally understood that if you promote and/or sell a particular brand name of product then there's some benefits in it for you and/or your company and if you, as a manufacturer, have the right connections, as GE, then throughout the industry your products will be more prominent, some regions more so than others.....trust me Eddie, I'm all about the conspiracy...
Easier math. Multiple by 1.06 to get the number you want the first time for 6%.
compacitor
If you say CUMPASITOR one more time, I'm gonna blow my brains out!!!
Hey Eddie,
Yea me too, stopped buying made in china crap replaced one call back 24 hours later and replaced again checked amp draw was ok, call back 30 days later and replaced with us made and I have not been back since... I think it pays to buy us if you can.
It is %10 up or down, you did .06 is not %10 isn't it Eddie? 54 is the number yours is 56.4
The cap that Eddiie tested is labeled plus or minus 6%. Not 10%. Also most are labled between three and 6 percent.
i know how u can check the capacitor, without the high dollar multimeter. Replace it, if it works that was the problem.
good idea
You don't need a pro grade meter like he uses to check a cap. Search multimeter on Amazon and you will find some cheap ones. Any meter with a MFD setting can be used for this test.
The best way for you to check a cap is to turn on the system and lick both your index finger and middle finger then use those fingers to touch the HERM and Common terminals of the cap while it is still connected to the equipment. Let me know how that works out for you.
awesome thanks,and just to let you know GE sucks on everything they make now
“Touching the contacts wont feel too good”.
Me: ya death never feels all that good to the touch or any other of the seven senses humans have. Same thing w electrical shock, heart failure and fry or discharge of electrical charges of the humans natural circuit.
Call a professional? Are you kidding. Our furnace went down and we called a "professional" from the company that sold us the unit. He replaced the motor capacitor and wired it incorrectly when he replaced it. As a result the blower motor turned too slow. That caused excessive heat build up in the heat exchanger. That, in turn, caused the furnace to catch on fire. It could have burned our house down. It took me several days of troubleshooting to find his mistake and correct it. I will NEVER hire another "professional".
david
“C” common? Lol hook it up to the “c” side of the compressor and see what happens! “C” hooks up to RUN.. “c” stands for capacitor
haha...swollened....I always get asked why do this caps go bad...I always tell them Heat and vibration...the age of the unit is also a factor...as the unit ages the amp draw will increase due to friction and winding degradation...you like that word?...lol...that's the slowest meter I've seen...haha...we like to use the USA made caps...all the cheap Gemaire or Goodman caps are crap...China makes crummy caps...
There is 23 not 22 capacitors
Really, does that matter?
LOL there is no M in capacitor
Couldn't watch past 1 minute. There is not a fucking M in capacitor. It's not a compacitor.
OMG, it's not compacitors it's capacitor and microfarads not macrofarrats. LOL, Great vid otherwise.
Micro-Ferrets...forgot one mate
Leave the guy alone. His contribution is far greater than yours.
Seriously? What are you--his bodyguard? SMH.
jcchandley LOL
Great explaining of testing derail.