Shortcut to calculate Turbine efficiency

Поделиться
HTML-код
  • Опубликовано: 24 янв 2025

Комментарии • 8

  • @devivara1162
    @devivara1162 2 года назад

    Sir what is difference between axcilary cooling water and main Colling water?????....and its uses in power plant?

    • @AS-wz7zz
      @AS-wz7zz  2 года назад

      Main cooling water is equipment cooling water for critical equipment like BFP, Compressor, Dryer, Lube oil cooler, Alternator cooler
      Auxiliary cooling water is used for cooling mainly for equipment coolig water through PHE

  • @devivara1162
    @devivara1162 Год назад

    Sir what is lube oil accumlator????when its uses???

    • @AS-wz7zz
      @AS-wz7zz  Год назад

      To absorb fluctuations in oil pressure during operation

    • @devivara1162
      @devivara1162 Год назад

      @@AS-wz7zz sir if pump oil pressure drop then how accumulator works???

    • @AS-wz7zz
      @AS-wz7zz  Год назад

      @@devivara1162 suppose running pump stops, by the time standby pump starts accumulator helps maintaining gradual decrease in pressure such that pressure reduce slowly as compared to without accumulator.
      accumulator provides enough time during pump changeover to prevent sudden pressure fall.

  • @devivara1162
    @devivara1162 2 года назад

    Sir what r the reasons condenser is under negative pressure??

    • @AS-wz7zz
      @AS-wz7zz  2 года назад

      To increase heat drop in turbine and efficiency of system