Review of a UNI-T UT8805E 5 ½ Digit Bench Multimeter

Поделиться
HTML-код
  • Опубликовано: 17 окт 2024

Комментарии • 21

  • @keyspost
    @keyspost 5 месяцев назад +1

    Thank you for such a detailed review of the UNI-T UT8805E bench multimeter, very professional and useful!

  • @piotrburnos1004
    @piotrburnos1004 5 месяцев назад +3

    Hi! I appreciate your reviews. I also do reviews on Polish YT channel (Metrology). But I lacked information: what are the mathematical functions? What are the display modes? What is the actual measurement frequency (VM comp output)? How can you trigger a multimeter? Accuracy is not everything...

    • @KerryWongBlog
      @KerryWongBlog  5 месяцев назад +3

      I tried to cover as much as I could in this video. If there are interests in these features I can demonstrate in a separate video.

  • @kuro68000
    @kuro68000 5 месяцев назад +2

    Thanks, I was considering one of these. The fan noise though... And it doesn't seem to be temperature dependent.

    • @KerryWongBlog
      @KerryWongBlog  5 месяцев назад +2

      Yeah, the fan is unfortunately on the noisy side and is constantly on.

  • @Mtaalas
    @Mtaalas 5 месяцев назад +1

    for 400€ or so, that's amazing performance... it's crazy the world we live in these days. Yeah i'm old... :D

  • @kevkabluebird1032
    @kevkabluebird1032 2 месяца назад

    Boot-up time, ye can agree with its importance. I use my old HP bench DMMs or even some sovjet-bench DMMs (all digital) quite often, as they have like no boot-up time at all (or just a sec) :D

  • @ChrisJackson-js8rd
    @ChrisJackson-js8rd 5 месяцев назад

    is the input impedance also why the display on my hp 3457a jumps around when not being used?
    i always wondered why it did that. the manual said it was normal but didn't get into the why.

    • @originalmianos
      @originalmianos 5 месяцев назад +1

      Stray electro magnetic fields, radio and all sorts things can induce voltage differentially in leads. Specially when there is a near open circuit at the meter. If you short the leads it will be dissipated as it has a path to balance it out. I have a 3478 myself with a very high input resistance/impedance and see the same.

  • @TechProbe
    @TechProbe 5 месяцев назад

    good measurement considering its price. at 15m22s, 0.020nF=20 pico Farad ??

  • @jspencerg
    @jspencerg 5 месяцев назад

    Did you verify the input impedance?
    I think you would have shown what a mediocre instrument this is if you'd compared it's performance to the ut-61e+.

  • @za_ozero
    @za_ozero 29 дней назад

    Is this device floating?

    • @KerryWongBlog
      @KerryWongBlog  29 дней назад

      The inputs are isolated if that's what you were asking.

    • @za_ozero
      @za_ozero 29 дней назад

      @@KerryWongBlog im asking if the device's negative input lead is at mains ground potential like most of oscilloscopes are. The device is mains powered so there's a difference to battery powered multimeter, unless there is a small isolation transformer inside the device to power it or something like that

    • @KerryWongBlog
      @KerryWongBlog  29 дней назад +1

      @@za_ozero Unlike oscilloscopes, bench multimeter's inputs are all isolated. The multimeter common input can be floated to +-500Vpp on this meter according to the spec and labeling on the front panel.

    • @za_ozero
      @za_ozero 28 дней назад

      @@KerryWongBlog thanks

  • @paulcohen1555
    @paulcohen1555 5 месяцев назад +1

    They forgot to type one 0 (zero) in the AC BW spec.

  • @rda6468
    @rda6468 5 месяцев назад

    teardown! thanks

  • @abzaman77
    @abzaman77 5 месяцев назад

    Teardown please!

  • @francoperrot9933
    @francoperrot9933 4 месяца назад

    Durante la visualizzazione dei grafici, quando la memoria è piena il multimetro si inchioda e bisogna spegnerlo per sbloccarlo, che schifo.
    La gestione della reimpostazione manuale delle soglie di un grafico è orribile, non compratelo se dovete visualizzare grafici.
    L'autoscaling non esiste, quello manuale non funziona se la memoria è piena, che schifo. L'istogramma lo trovo inutilizzabile.