First you should check if the main fuse is ok. If yes, check the power switch. After that, check the battery electrolytes and cables, as well as the controller. This error appears as a voltage-related error.
Hello.Getting a parts catalog or any service documents from Jungheinrich is not that easy, but there are many sites on the Internet that sell spare parts for forklifts and electric pallet trucks from various manufacturers
Self test Contactor contact closed instead of opening When switched on, the capacitor voltage should be one volt (1 V) below the battery voltage. - Check the output of the main contactor of the control system; - check the wire connection; - replace the contactor; _ 1 2 Self-test Contactor contact open instead of closed After contactor activation, the capacitor voltage must be equal to the battery voltage (within 500 ms.), otherwise an event message is triggered. - Check the output of the main contactor of the control system; - check the wire connection; - replace the contactor; _ 1 3 Self test Main contactor permanently on. An attempt is made to open the main contactor. The event message is triggered when the controls detect after T> time limit that the main contactor does not open. - Replace the control system; Lithium-ion battery 24 V/110 Ah (in case of repeated occurrence): - Check the cable harness of the lithium-ion battery, replace it if necessary; - replace the battery contactor; - replace the battery management system (BMS); _ 1 4 Self test Mode of operation Main contactor feedback input to set state implausible Status of the feedback signal for activation of the main contactor implausible (initiation of error after the time limit) - Check the main contactor output of the control system; - check the wire connection; - replace the contactor;
And for error 0304?
Ola amigo. Vc sabe o que causa o erro E 150.1 transpaleteira ere 120 jungherinch? Desde ja agradeço.
Hi, do you know the error code E 1953 for pallet truck EJE120 ? Lifting is ok, but if want to move, i have to press the turtle slow button.
Shunt button no fixed when you install control head upper
hello men, one questions, yu know any about code E1104, this truck no drive, no lift, tks
hello I'm not sure but I think the controller is the problem
@@repairityourself tks, bro, i have same idea
Tq sir
Hi could I ask if the truck was functions where still working. I have the same error but every now and again the truck keeps cutting out
Hello. Works and no more error
@@repairityourself I have the same error. The truck works but keeps cutting out when driving. Do you know what it could be?
First you should check if the main fuse is ok. If yes, check the power switch. After that, check the battery electrolytes and cables, as well as the controller. This error appears as a voltage-related error.
@@repairityourself thankyou so much for the help.
Hello how can i fund The parts catalog for eje 116.
Hello.Getting a parts catalog or any service documents from Jungheinrich is not that easy, but there are many sites on the Internet that sell spare parts for forklifts and electric pallet trucks from various manufacturers
ciao ho un codice di errore E 1925 non riesco a levarlo che cose
Any idea what a e 4506 is?
Unfortunately, this error code is unknown to me
Hi. Jungheinrich ERE225 - error E 3102. No drive, no stering, lift OK.
Hello. Check the cable from the handle to the controller
Hello Error 4372
i think E4372 is tillerhead error.
Replace Control head upper
Eror0305
Erreur 0102
Self test Contactor contact closed instead of opening When switched on, the capacitor voltage should be one volt (1 V) below the battery voltage. - Check the output of the main contactor of the control system; - check the wire connection; - replace the contactor; _ 1 2 Self-test Contactor contact open instead of closed After contactor activation, the capacitor voltage must be equal to the battery voltage (within 500 ms.), otherwise an event message is triggered. - Check the output of the main contactor of the control system; - check the wire connection; - replace the contactor; _ 1 3 Self test Main contactor permanently on. An attempt is made to open the main contactor. The event message is triggered when the controls detect after T> time limit that the main contactor does not open. - Replace the control system; Lithium-ion battery 24 V/110 Ah (in case of repeated occurrence): - Check the cable harness of the lithium-ion battery, replace it if necessary; - replace the battery contactor; - replace the battery management system (BMS); _ 1 4 Self test Mode of operation Main contactor feedback input to set state implausible Status of the feedback signal for activation of the main contactor implausible (initiation of error after the time limit) - Check the main contactor output of the control system; - check the wire connection; - replace the contactor;
Sometimes cleaning the contactor helps.