Submersible Water Pump VS Lal Pump in Pakistan

Поделиться
HTML-код
  • Опубликовано: 8 сен 2024
  • This video about water pumps like deep well ejector pump (Lal Pump) and Submersible Pump (Missile Pump or Missile Motor). Best Submersible pump in Pakistan and solar jet pumps.
    If your face the water problems like pani ka bar bar uthar jana, water pump low pressure then a missile pump is a good choice for you.
    Also discussed can submersible is installed in a simple bore? and other quires like the best submersible pump in Pakistan.
    More Interesting Videos:
    Wall Crack Repair | Lanter and Wall Cracks Repair Solution and Reasons | Home Improvement
    • Wall Crack Repair | La...
    Seelan Wali Dewar | Old Wall Dampness Treatment | Wall Seelan Kaise theek Karen
    • Seelan Wali Dewar | Ol...
    LED Bulb & Lights: Why do LED bulbs stop working?
    • LED Bulb & Lights: Why...
    LED Bulb Repair at Home Easily
    • LED Bulb Repair at Hom...
    Convert Energy Saver to LED Bulb Yourself at Home Easily
    • Convert Energy Saver t...
    Bike Headlight Low Light Problems | बाइक हेडलाइट कम रोशनी की समस्या
    • Bike Headlight Low Lig...
    Electric Bike for Girls | No Kick, No Gear, Especially Design for Ladies | Scooty for Girls
    • Electric Bike for Girl...
    Motorcycle not starting in cold weather? | Best Petrol Setting For Summer and Winter at Home
    • Motorcycle not startin...
    Stove Repair at Home easily | Chulha Repairing | गैस चूल्हे के पीली आग को ठीक कैसे करें
    • Stove Repair at Home e...
    Gas Stove Repair: Stove Knob Stuck and Flame too Low | गैस स्टोव मरम्मत
    • Gas Stove Repair: Stov...
    Gas Stove Cleaning: Chulha Saaf Karne Ka Tarika | Kitchen Appliances Cleaning
    • Gas Stove Cleaning: Ch...
    Microwave Oven Repair: Microwave Oven Not Heating Problems Solution at Home
    • Microwave Oven Repair:...
    Best Glass Cleaning Agent Homemade | Mirror Cleaning | Windscreen Cleaning
    • Best Glass Cleaning Ag...
    Refrigerator Rubber Repair: How to Clean & Repair Fridge Door Rubber at home easily
    • Refrigerator Rubber Re...
    Repair Handsfree: Repair Handsfree Without Soldering Iron | One side not working?
    • Repair Handsfree: Repa...
    Silai Machine Repair: 80% Stitching Problems Solution in One Video of Sewing Machine
    • Silai Machine Repair: ...
    Affordable Long Range Wi-Fi Repeater With 3 Ethernet Ports | Complete Installation Guide
    • Affordable Long Range ...
    Gas Stove Cleaning: Chulha Saaf Karne Ka Tarika | Kitchen Appliances Cleaning
    • Gas Stove Cleaning: Ch...
    Pressure Cooker: Pressure Cooker Repair at Home | Pressure nahi ban raha?
    • Pressure Cooker: Press...
    Engineer Setup gives you the easiest method to make usable things from waste products and repairing and maintenance of home appliances at home DIY. Please subscribe to my channel so that I can get the power to do work more efficiently.
    RUclips Channel "Engineer Setup"
    Follow us on Social Media!!!
    FACEBOOK: / engineersetup
    INSTAGRAM: / engineersetup
    TWITTER: / engineersetup
    PINTEREST: / engineersetup

Комментарии • 605

  • @saadanwar7914
    @saadanwar7914 Год назад +5

    video is good, informative but you should have concluded with price , cost invloved for everthing, please make a video again for a short on this, as if someone is thinking to get this installed he or she needs information on what might work as well the cost involved , so prcing video on these devices and machines is much much appreciated and encouraged🙂😊

  • @majidkhanzindabad2699
    @majidkhanzindabad2699 2 года назад +4

    Hmaari aj hi motor khrab hui ha to yh video bht helpful sabit hui ha 👌keep it up bro ❤️

    • @EngineerSetup
      @EngineerSetup  2 года назад +2

      Thank you so much for your appreciation and support 👍😊🙏

  • @faisalkhalid9570
    @faisalkhalid9570 2 года назад +1

    ماشاءاللہ بہت اچھی معلوماتی ویڈیو بنائی یے شکریہ

    • @EngineerSetup
      @EngineerSetup  2 года назад +1

      Thank you so much for your appreciation and support 👍😊🙏

  • @naveedazam8715
    @naveedazam8715 2 года назад +6

    Thank you Engineer. I have learned a lot ! JazakAllah !!!

    • @EngineerSetup
      @EngineerSetup  2 года назад +1

      Thank you so much for your appreciation and support 👍😊🙏

    • @ShahidAli-zz5cr
      @ShahidAli-zz5cr Год назад

      ​@@EngineerSetup no doubt excellent information

    • @ShahidAli-zz5cr
      @ShahidAli-zz5cr Год назад

      ​​@@EngineerSetup let me guide
      2 inch delivery submersible pump
      K liay kitni solar panels plate lgwain
      water 💧 deep 100/120ft

  • @MuhammadKamran-cw8zm
    @MuhammadKamran-cw8zm 10 дней назад

    Well explained the difference

  • @safdarrafi8236
    @safdarrafi8236 3 месяца назад +1

    JazakAllah good information

  • @azmarihsan7900
    @azmarihsan7900 2 месяца назад

    Buht achi achi batain app nay keh Dee jazakallah

  • @nabeelali1125
    @nabeelali1125 Год назад +1

    thanks bro kafi information mili

  • @aftabahmed3682
    @aftabahmed3682 2 года назад +1

    valued information, that shows you have knowledge and experience.

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

    • @adeelimran9372
      @adeelimran9372 2 года назад

      Assalam u alaikum bhai Kesy hain ap ? Bhai mere Ghr ka missile pump jb off Krain to bhot zyada vibrate krta Hy, pipe bhot vibrate krty hain ..is problem ka solution btaiye ??

  • @adeelimran9372
    @adeelimran9372 2 года назад

    Very informative videos hoti hain apki,, MASHALLAH

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @TheMotivationHub247
    @TheMotivationHub247 4 месяца назад +1

    Boht sari videos k bad koi real informative video mili ha but the thing is mera pump lega howa ha or ab ma na solar system per shift krna ha but solar inverter k through mera bore 400 foot ha ab is ma si gle ampeler legao ya phir ye mazail wala 2 inch wala dalwao pump basically muja wo pump chaheya jo jhatka kum legao torq kum la start ma or efficient bhe ho pani nikalna ma or 3rd floor pa bhajna ma

  • @mohammadsarwar3933
    @mohammadsarwar3933 2 месяца назад +1

    thanks bhai

  • @nazakatali855
    @nazakatali855 11 месяцев назад +2

    Thanks so much ❤
    370. Feet bore which one is best. ?

  • @ayubnasir8219
    @ayubnasir8219 3 месяца назад

    MANY THANKS, MY DEAR.

  • @mirzanasir4798
    @mirzanasir4798 Год назад

    Nice information about sub mersible pumps

  • @msaad7738
    @msaad7738 2 года назад

    Salaam alaikum pyare Bhai kya hal hai aapki vajah se Zindagi bahut aasan ho gayi hai Allah Tala aapko Zindagi tandurusti wali ata farmae

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @makhmalistudio7379
    @makhmalistudio7379 2 года назад +1

    Zabardast video Allah bless you my friend

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @zahidlatif874
    @zahidlatif874 2 месяца назад +1

    Good

  • @Faisaliub
    @Faisaliub Год назад +1

    Bore 120 feet tak ho aue 4th floor tak water ly kar janay k laya specifications detail main baten please...

  • @Bahawalpur370
    @Bahawalpur370 2 года назад

    جزاک اللہ الخیر

  • @usamatabeerchannel928
    @usamatabeerchannel928 2 года назад +1

    جوشخص اس لیے اپنی اصلاح کر رہا ہے کہ دنیا اس کی تعریف و عزت کرے اس کی اصلاح نہیں ہوگی ۔ اپنی نیکیوں کا صلہ دنیا سے مانگنے والا انسان نیک نہیں ہوسکتا۔ ریا کار اس عابد کو کہتے ہیں جو دنیا کو اپنی عبادت سے مرعوب کرنا چاہے۔

  • @abdulsalamsheikh4706
    @abdulsalamsheikh4706 2 года назад +2

    Engineer sab Lal pump or monoblock ka frq btden 3rd floor k lea?

  • @shoukatali2863
    @shoukatali2863 9 месяцев назад +1

    Depth100 feet 4inches pipe already fitted over head tank on first floor roof please suggest which submersible water pump is best for said condition and what exseseries indeed please reply as soon as possible thank you sir.

  • @aijazakbar4851
    @aijazakbar4851 9 месяцев назад

    Good information thanks

  • @mohammadtayyab7656
    @mohammadtayyab7656 2 года назад

    Acha samjaya Hy ,
    Agr White board py , devide KR k samjaty to bhout bhtreen hota

    • @EngineerSetup
      @EngineerSetup  2 года назад +1

      Jee innshaAllah iss tarah ka bi koi setup bnata hon 👍

  • @mariyamiyan2144
    @mariyamiyan2144 2 года назад +1

    Informative video

    • @EngineerSetup
      @EngineerSetup  2 года назад +1

      Thank you so much for your appreciation and support 👍😊🙏

  • @asifkhokhar1206
    @asifkhokhar1206 2 года назад +7

    سر اگر پانی کا لیول 40 فٹ ہو تو انجیکٹر کم سے کم کتنے فٹ گہرا لگانا چاہئے ؟ اور انجیکٹر سے نیچے پائپ کس سائز کا لگانا چاہئے.

  • @abuhamzafazalhaq2182
    @abuhamzafazalhaq2182 2 года назад

    Very useful information .
    Thank you

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @SherKhan-gn8in
    @SherKhan-gn8in 3 месяца назад +2

    آپ نے ان سب کی قیمت کا نئ بتایا اور کس کمپنی کا سولر پمپ کوالٹی میں سب سے اچھا ھے

  • @kohistanichand6733
    @kohistanichand6733 2 года назад +4

    اسلام علیکم
    120 فٹ بورنگ ہوئی ھے اور لال پمپ لگا ھے اس کی وجہ سےبجلی کا بل بہت زیادہ آتا ھے ۔ ۔ ۔ ۔
    کیا سمر پمپ لگا لے ؟
    پانی سیکنڈ فلور پر چڑھانا ہوتا ھے۔۔۔۔۔ رہنمائی فرمائیں

  • @dr.manzoornaeem7357
    @dr.manzoornaeem7357 2 года назад

    very nice detail brief. thanks.

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 😊👍🙏

  • @mariyamiyan2144
    @mariyamiyan2144 2 года назад +2

    Really great channel 👍 👏 👌

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @farhankhan-cc6ui
    @farhankhan-cc6ui Год назад +1

    120 feet and double story . Koi acha sa dc pump btahiye . Shahzad pump 12 theek rhe ga ??
    Im from Faisalabad city .

  • @mukhtarahmad4181
    @mukhtarahmad4181 2 года назад +1

    Mera pass 8 kanal zameen hi. Lal pump ka new boor hi 100 foot ka water level 45 foot hi konsa pump use kroon. Pani ka pressure bhe acha ho guide me brother

  • @multifarming7074
    @multifarming7074 2 года назад

    apane achhi research k hai great keep it up man

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @zaheerafzal1263
    @zaheerafzal1263 3 месяца назад +1

    Sir me ne Lal pump ka 150 feet bore krwaya h kia me is bor per sumberibal lga skta hn

  • @herohonda2239
    @herohonda2239 2 года назад

    Thanks. very informative

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @aminasultan3013
    @aminasultan3013 2 года назад

    Bht hi.khoob vedio

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @ejazhussain8301
    @ejazhussain8301 2 года назад

    Very informative

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @muneerahmedmemon9760
    @muneerahmedmemon9760 11 месяцев назад +1

    Aslamoalaikum
    Sir me solar dc pump lagvana chahta hu jo line jo ghar se 80 ft door hea se pani kheench kar direct 50 ft overhead tank me aea us k lea mujhea konsa dc solar pump lagwana chahea.

  • @amjidtaqi2743
    @amjidtaqi2743 2 года назад

    Thanks a lot bhai

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @razibutt6111
    @razibutt6111 2 года назад

    excellent sir ...informative

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @ghulamyasin7091
    @ghulamyasin7091 Год назад +1

    Aoa
    Can u guide me,my existing water pump bore is 300 feet. Water is available at 75 feet ,injector is installed at 65 feet and 4 inch pipe is 100 feet .
    How we can install submersible pump as it cannot go into water and will hang at injector level where 2 inch pipe is existing.....
    is there any solution?

  • @yasmeenmalik8472
    @yasmeenmalik8472 2 года назад

    Very informative video

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @najamahmad6055
    @najamahmad6055 2 года назад +1

    I want to o replace 05 HP mono block to 1 1/2 HP submersible pump under ground tank to 5 story flat 100ft distance it is suitable ? for energy saving

  • @CREATIVELAUNCH777
    @CREATIVELAUNCH777 2 года назад

    thanks for reply

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @malikrizwanassar3790
    @malikrizwanassar3790 2 года назад

    Thank you sir

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @raojawwad8968
    @raojawwad8968 2 года назад +1

    Well

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @alishahbaz1968
    @alishahbaz1968 2 года назад +1

    Aso sir 3 inch pani k leay dc mezail ya ac 220 v mezail acha hey

  • @khawarafroze4421
    @khawarafroze4421 2 года назад

    Very useful video

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @amirrhassan9664
    @amirrhassan9664 2 года назад

    Brother,u have given good information .
    I want to install a solar system on my existing tube well.
    Water level 110 -120 feet
    Bore depth. 250 feet
    5 inch delivery.
    Please guide some workable best solution.

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Tube well per main kosish karo ga jald video bna don 👍

  • @RanaImdad-uz4um
    @RanaImdad-uz4um 3 месяца назад

    Sir hamraay area men total bore 60ft our water level 20 ft he 1 scar zamin ke laye Kon sa pump lagana he jab ke Pani ouper nahi phakana

  • @tahirpml76
    @tahirpml76 2 года назад

    Informative

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @zulfiqarhussain2713
    @zulfiqarhussain2713 2 года назад

    Thanks

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @anwarbaloch2033
    @anwarbaloch2033 Год назад +1

    Asad Bhai hamare pas Lal pump hai 2.5 3 HP ha shayd wo itna meter ko speed me chalta ha KY hamare Ghar 200 Mahine ka wo 10 din me Pura kedeta ha ab ham cha rahy hen ky wo pump nikal WA kr uski jaga sumer lagain to sumer ka pump ktna speed leta ha ktne HP hota ha wo 200 unit Mahina nikal lega agr lagwain to is bare me Thora guide krde ya koi asi videos ka batain taky wahn se help ho sky jis me meter ka bhi batay

  • @hassanqamar5019
    @hassanqamar5019 2 года назад +1

    Ghar keh swimming pool ( 15 x 15 )
    orr Lawn plants 🪴 keh liay Kong sa mizile pump theek hai ?? Solar Wala ..

  • @zahidhussain631
    @zahidhussain631 2 года назад +1

    Sir pani garm ata ha itni garmi ma kasa use Karin koe solution misil moter ka plz

  • @junaididrees5765
    @junaididrees5765 2 года назад

    Good information ✔

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @UmarFarooq-hp9wt
    @UmarFarooq-hp9wt 2 года назад +1

    Good information 530 feet Ka lia kn si misiel motor best ha?

  • @nikayjayeshorts
    @nikayjayeshorts Месяц назад

    250 meter bore which specification Subermersil pump is best

  • @KhalidKhan-mm8bu
    @KhalidKhan-mm8bu 2 года назад

    MAshAllah 💯👍👍👍👍

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @user-yz3xr3hc2b
    @user-yz3xr3hc2b 14 дней назад +1

    السلام علیکم بھائی صاحب 200 فٹ موٹر لگوانی ہے تو وہ کونسی لگانی ہے اور اس کی پرائز کیا ہے مہربانی ہوگی اپ ہمیں اچھا مشورہ دے دیں

  • @ReachStacker-ji9yx
    @ReachStacker-ji9yx 4 месяца назад

    Can we use WARM PUMP on boring

  • @ashrafchma131
    @ashrafchma131 Год назад

    Jeo hero 👍 good

  • @AbdulghaffarGhaffar-in6iq
    @AbdulghaffarGhaffar-in6iq 11 месяцев назад +1

    Yar Aap ni 48volt dc ki power ka nahi bataya keh woh kitni gehrai se pani nikal sakta hain

  • @GreenPakistan92
    @GreenPakistan92 Год назад

    Well done

    • @EngineerSetup
      @EngineerSetup  Год назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @MohsinKhan-es3zu
    @MohsinKhan-es3zu 2 года назад

    Good video

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @shahidattari6118
    @shahidattari6118 2 года назад

    Nice information

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

    • @user-ko4lc1ky7r
      @user-ko4lc1ky7r Месяц назад

      Aoa​@@EngineerSetup

  • @zabeebulhaq2812
    @zabeebulhaq2812 2 года назад

    Very good

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @mirzabaig7876
    @mirzabaig7876 Год назад

    mirza sahib .kiya electric meter se DB tak wire L 7/52 aur N 7/44 dale ja sakte hai ? please/

  • @naseershah5617
    @naseershah5617 6 месяцев назад

    Sir
    Mujy two hs pump chi or one inch waly or 30foot nichy pani ha or 1000foot tak ly jan ha

  • @naseebkhan7774
    @naseebkhan7774 2 года назад

    Ma sha Allah good information i watched your first video and subscribe your Chanel

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @LOGOUT822
    @LOGOUT822 6 месяцев назад

    Assalamualikum sir
    Mary ghr main 220sy 2500 feet Ka boor ha or main usy solar plates par direct chalana chat ho koe hal bato KY boar bhi na Karna pary

  • @tariqmahmood8974
    @tariqmahmood8974 Год назад

    Sir ham na zamean ko pani lagana k lea lagana ha kis size tak mizale pump mil sutka ha yani k 6 inch tak mil jay ga dc mizaile

  • @UmerAli-yk5nu
    @UmerAli-yk5nu 2 года назад

    WA.ALAIKUM.ASSALAAM

  • @muhammad.iqbal.4026
    @muhammad.iqbal.4026 2 года назад +1

    China ka JD. Missile 1 ya1.25HP.. valla 170 feet neeche sey oor ooper 50 feet pani tank tak preesure sey deliver karta he oor sallon karab b nahi hota.

  • @abdulrazzaqrehanghani8457
    @abdulrazzaqrehanghani8457 2 года назад

    Asad Bhai lowara Italian pump ki captivity aur performance k baray Mai batain dair hp ki

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Jee main innshaAllah jald video bna don ga…👍

  • @waheedkhan9425
    @waheedkhan9425 9 месяцев назад +1

    Salam bhai. Jahan pe water level kum hota h. 15f ya 20f to kia wahan pe bhi submarcibl pump laga saktay hn?

  • @SardarShahid-ne7xs
    @SardarShahid-ne7xs 2 месяца назад

    550 ft k Liya kn se mother sahi rhay ge bhi

  • @tariqbutt8961
    @tariqbutt8961 2 года назад +1

    MR. Engneer Sab. Zabardast Information. Jazakallah. Mr. Agar boor 500 Ft. Ho to con c Motorpump Lugwa Chahia ! Ground Under ground Water tank tak ! Our Ground water tank say 5 th Floor tak con si Moter Lagwani chahia Pls ZAROOR Bataya ga. JAZAKALLAH. Yes Agar Apna W. APP # Public kar day too THANK YOU.......

    • @EngineerSetup
      @EngineerSetup  2 года назад

      500 ft ky liya 3 HP ka submersible pump lagwayn, ore ground tank per 1 HP ka monoblock pump lagyn

    • @tariqbutt8961
      @tariqbutt8961 2 года назад

      @@EngineerSetup JAZAKALLAH......

  • @user-ir1yq4wx2e
    @user-ir1yq4wx2e 4 месяца назад +1

    Brother apse Kuch info Leni ha mil jaye gi kindly...

  • @zoyafarooq_85
    @zoyafarooq_85 Год назад

    48 volts BLDC motor can throw the water to send floor at 24 height and with ground water depth of 120 feet.

  • @arslantayyab62
    @arslantayyab62 5 месяцев назад

    Aslam o Alikum.
    Bhai hamara laal pump laga howa hy 2 hp ka bohut ziada bijli laita hy.
    Koi dc pump suggest kar dain. Boor 80 feet ka hy. Or tank 60feet ki onchai pay hy

    • @EngineerSetup
      @EngineerSetup  5 месяцев назад

      Missile pump laga lyn yah vfd sath lagyn

  • @onlineonline2189
    @onlineonline2189 4 месяца назад

    Aslamo alekum bahi lal pump Acha he ya mizael pump ham 400 fet boor karwana he gahr men en dono men se kun sa sehi rahy ga plezz help me

  • @engineerirfan
    @engineerirfan 2 года назад

    NICE DEAR BRO

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @ShahidAli-zz5cr
    @ShahidAli-zz5cr Год назад

    Masha Allah

    • @EngineerSetup
      @EngineerSetup  Год назад +1

      Thank you so much for your appreciation and support 👍😊🙏

    • @ShahidAli-zz5cr
      @ShahidAli-zz5cr Год назад +1

      @@EngineerSetup please guide 2 Inch delivery submersible pump ko solar pr chalaine,water depth 80/100 ft to kitnai watt kee kitni solar panels plate lgwaine

    • @ShahidAli-zz5cr
      @ShahidAli-zz5cr Год назад

      @@EngineerSetup waiting your guidance

  • @hassanqamar5019
    @hassanqamar5019 2 года назад +1

    Kitney Solar required hotey hey mizile Dc pump keh liay. Swimming pool size (15x15) keh liay.
    DC pump cost kua hoo gi??

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Pump 5000 say start hota hy DC ore 25000 tak jata hy commonly

    • @hassanqamar5019
      @hassanqamar5019 2 года назад

      Kitney solar panels ki zaroorat hoo gi ?

  • @mariyamiyan2144
    @mariyamiyan2144 2 года назад +1

    I subscribe you best of luck for your channel

    • @EngineerSetup
      @EngineerSetup  2 года назад +1

      Thank you so much for your appreciation and support 👍😊🙏

    • @mariyamiyan2144
      @mariyamiyan2144 2 года назад +1

      @@EngineerSetup welcome brother 🙏 best of luck 👍

  • @ayubpatel6421
    @ayubpatel6421 2 года назад

    Mr. Engg. Thank y . Is there is any good replace ment of suction pump for home use.

  • @nawabchannal3323
    @nawabchannal3323 2 года назад +1

    Salam
    Vlog dekha kafi informatic hay
    Men ye poochhna chahta hoon k
    1 2" walay snmber pump ko agar ham 30 ft high lagaa len yaani boar ka pipe hi oopar tak le jaaen to ???
    Kia wo efective hoga ??
    2 dono size 2" 4" ki 200 ft ki price andazann ???
    Ac ki aor dc ki dono ki price aapkay andazay k mutabiq kitni hay ???

  • @attadesivideos5159
    @attadesivideos5159 2 года назад

    Nice 👍 beautiful 🌹

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Thank you so much for your appreciation and support 👍😊🙏

  • @zai331
    @zai331 Год назад

    Hmra pani thora kam hai is 107 foot bor hai is mai kita misial motor laga sakte hain injector pump pani uthana chor dyta hai

  • @malikaqib8530
    @malikaqib8530 Год назад

    Sir 40 fit bor hai lekin dc pump pani nhi utha. Rha injector motor k sath hi lagaya howa hai injector ko neeche le jae ya koi or masla hai motor bilkul sahi hai pani utha rhi hai

  • @muhammadislamrana368
    @muhammadislamrana368 Год назад

    Sir kia koi switch he zameen man pani khatam hone pump ko off ker de

  • @allarunder5572
    @allarunder5572 Год назад

    Lal pamp ki jga AC Wala lgana ha.waterlevel 85 fit gehrai 250 fit

  • @muhammadirfan202
    @muhammadirfan202 Год назад

    I have already a submersible motor installed
    Due to high bills of electricity is it possible that I may switch to DC submersible pump .Pls do reply

  • @accollect9726
    @accollect9726 2 года назад

    Donke pump ki video or bikian change krne ki video banain

    • @EngineerSetup
      @EngineerSetup  2 года назад

      Jee main innshaAllah jald video bna bna don ga 👍

  • @syedsaada9922
    @syedsaada9922 Год назад

    Hmare plat me 22feets pe boring ka Pani Ata hai lekin bht slow nichy Wala tang bhrta hai me apna 4th floor pe rehta hn Tanki 5pe hai Chat pe me Chahta hn koi aesa mujhe Tariqa btao k me apna connect kr k boring se direct apni Tanki pe Pani bhrlun

  • @mukaramali7915
    @mukaramali7915 2 года назад

    Ji mujhe solar se 500 fitt ghahrai se pnani uthana hai 2 ench pipe se kia mumkin hai k nehi?

  • @fahamkhan8716
    @fahamkhan8716 Год назад

    Bhai. Hamari mote m 6amp ka Breaker lgta tha. Lekin ib 8 amp ka b laga doya wo trip kr raha h .
    KIYA WAJAH h is trah Q bar bar Breaker kharab horhe hn or trip kr rahi .